{"id":1232,"date":"2026-10-13T14:16:00","date_gmt":"2026-10-13T14:16:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/base-8-vs-base-12-mpo\/"},"modified":"2026-10-02T09:53:09","modified_gmt":"2026-10-02T09:53:09","slug":"base-8-vs-base-12-mpo","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/ar\/base-8-vs-base-12-mpo\/","title":{"rendered":"\u0627\u0644\u0643\u0627\u0628\u0644\u0627\u062a MPO \u0630\u0627\u062a \u0627\u0644\u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u062b\u0645\u0627\u0646\u064a\u0629 \u0645\u0642\u0627\u0628\u0644 \u0630\u0627\u062a \u0627\u0644\u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u0627\u062b\u0646\u064a \u0639\u0634\u0631 \u0644\u0633\u0631\u0639\u0627\u062a 400G \u0648800G"},"content":{"rendered":"<p><strong>Base-8 aligns naturally with many eight-lane parallel interfaces, while Base-12 can remain practical in installed structured cabling and duplex breakout designs. The better architecture is the one with a documented lane map and migration path, not the one with the larger installed base or the newer label.<\/strong><\/p>\n<p>A data centre may contain Base-12 trunks from earlier deployments and new Base-8 modules for parallel optics. Replacing everything is not automatically justified, but mixing systems without a map can strand fibres or create unexpected polarity conversions. Evaluate channel utilization, module availability, testing and operational change together.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-spine-leaf-topology.jpg\" alt=\"Spine-leaf network topology planned with Base-8 or Base-12 trunks\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for base-8 vs base-12 MPO?<\/h2>\n<p>\u0627\u0633\u062a\u062e\u062f\u0645 \u062c\u062f\u0648\u0644 \u0627\u0644\u0642\u0631\u0627\u0631 \u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u0645\u0648\u0636\u0648\u0639 \u0625\u0644\u0649 \u0645\u062f\u062e\u0644\u0627\u062a \u0645\u062d\u062f\u062f\u0629 \u062a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0634\u0631\u0627\u0621 \u0648\u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0648\u0627\u0644\u0642\u0628\u0648\u0644. \u064a\u062c\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0643\u0644 \u0635\u0641 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0645\u0633\u0627\u0631 \u0648\u0627\u0644\u0648\u062c\u0647\u0629\u060c \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0646\u0633\u062e\u0647 \u0645\u0646 \u0643\u062a\u0627\u0644\u0648\u062c \u0639\u0627\u0645.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0645\u062c\u0627\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631<\/th>\n<th>\u0645\u0627 \u0627\u0644\u0630\u064a \u064a\u062c\u0628 \u062a\u062d\u062f\u064a\u062f\u0647<\/th>\n<th>\u0644\u0645\u0627\u0630\u0627 \u0647\u0630\u0627 \u0645\u0647\u0645\u061f<\/th>\n<th>\u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0627\u0644\u0627\u062d\u062a\u0641\u0627\u0638 \u0628\u0647\u0627<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lane utilization<\/td>\n<td>Live positions for each optical interface<\/td>\n<td>Shows stranded capacity<\/td>\n<td>Per-interface fibre map<\/td>\n<\/tr>\n<tr>\n<td>Installed plant<\/td>\n<td>Existing trunk count and polarity<\/td>\n<td>Changes migration cost<\/td>\n<td>Audited asset record<\/td>\n<\/tr>\n<tr>\n<td>Module strategy<\/td>\n<td>Cassette and conversion-module availability<\/td>\n<td>Determines usable endpoints<\/td>\n<td>Approved bill of materials<\/td>\n<\/tr>\n<tr>\n<td>Testing<\/td>\n<td>Access to every position and reference interface<\/td>\n<td>Affects commissioning effort<\/td>\n<td>Test method and adapters<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0647\u062c\u0631\u0629<\/td>\n<td>Next two equipment generations<\/td>\n<td>Prevents dead-end design<\/td>\n<td>Stage-by-stage topology<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control base-8 vs base-12 MPO in the Project<\/h2>\n<p>\u062a\u0631\u0628\u0637 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u062f\u0646\u0627\u0647 \u0628\u064a\u0646 \u0627\u0644\u0631\u0633\u0645\u060c \u0648\u0627\u0644\u0639\u064a\u0646\u0629\u060c \u0648\u062f\u0641\u0639\u0629 \u0627\u0644\u0625\u0646\u062a\u0627\u062c\u060c \u0648\u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629. \u0648\u0642\u062f \u0635\u064f\u0645\u0645\u062a \u0647\u0630\u0647 \u0627\u0644\u0639\u0646\u0627\u0635\u0631 \u0644\u062a\u0643\u0648\u0646 \u0639\u0645\u0644\u064a\u0629 \u0628\u0634\u0643\u0644 \u0645\u062a\u0639\u0645\u062f: \u0641\u0643\u0644 \u0645\u0646\u0647\u0627 \u064a\u064f\u0646\u0634\u0626 \u0633\u062c\u0644\u0627\u064b \u064a\u0645\u0643\u0646 \u0644\u0641\u0631\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a \u0648\u0627\u0644\u0647\u0646\u062f\u0633\u0629 \u0648\u0627\u0644\u0639\u0645\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0645\u0631\u0627\u062c\u0639\u062a\u0647 \u0644\u0627\u062d\u0642\u064b\u0627.<\/p>\n<h3>Model real interfaces<\/h3>\n<p>List the exact optics planned for each stage. Speed labels alone do not define lane count or whether the interface is parallel or duplex.<\/p>\n<h3>Calculate channel utilization<\/h3>\n<p>Mark active, spare and unused fibres for every path. Include cassette or harness conversions rather than evaluating the trunk in isolation.<\/p>\n<h3>Control mixed systems<\/h3>\n<p>Use distinct labels and documented modules where Base-8 and Base-12 coexist. Do not allow field teams to choose conversion hardware by connector shell alone.<\/p>\n<h3>Keep test access<\/h3>\n<p>Confirm that reference cords, MPO interfaces and polarity tools cover the chosen construction. A migration design is incomplete if the installed channel cannot be verified.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/02\/MPO-Connector.jpg\" alt=\"MPO connector used in Base-8 and Base-12 cabling\" width=\"783\" height=\"783\" \/><\/figure>\n<h2>\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u0644\u062a\u0633\u0644\u064a\u0645<\/h2>\n<p>\u064a\u062c\u0628 \u0627\u0644\u0627\u062a\u0641\u0627\u0642 \u0639\u0644\u0649 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0648\u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0642\u0628\u0644 \u0628\u062f\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u0641\u0645\u0646 \u0627\u0644\u0635\u0639\u0628 \u0627\u0644\u0627\u0633\u062a\u0641\u0627\u062f\u0629 \u0645\u0646 \u0623\u064a \u0646\u062a\u064a\u062c\u0629 \u0644\u0627 \u064a\u0648\u062c\u062f \u0644\u0647\u0627 \u0645\u0633\u0624\u0648\u0644 \u0645\u062d\u062f\u062f \u0639\u0646 \u0627\u0644\u0633\u062c\u0644 \u0623\u0648 \u0625\u062c\u0631\u0627\u0621 \u0645\u062d\u062f\u062f \u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0634\u0644\u060c \u0648\u0630\u0644\u0643 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0625\u0641\u0631\u0627\u062c \u0639\u0646 \u0627\u0644\u0634\u062d\u0646\u0629 \u0623\u0648 \u0628\u062f\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062a\u062d\u0642\u0642<\/th>\n<th>\u0627\u0644\u0637\u0631\u064a\u0642\u0629<\/th>\n<th>\u0627\u0644\u0633\u062c\u0644<\/th>\n<th>\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0641\u0634\u0644<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Asset audit<\/td>\n<td>Record trunk bases and polarity<\/td>\n<td>Rack map<\/td>\n<td>Correct unknown links<\/td>\n<\/tr>\n<tr>\n<td>Lane map<\/td>\n<td>Map every planned optic<\/td>\n<td>Utilization table<\/td>\n<td>Reject stranded design<\/td>\n<\/tr>\n<tr>\n<td>Module fit<\/td>\n<td>Build representative channel<\/td>\n<td>\u062a\u0642\u0631\u064a\u0631 \u0627\u0644\u0637\u064a\u0627\u0631<\/td>\n<td>Change cassette or harness<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0642\u0637\u0628\u064a\u0629<\/td>\n<td>Test all positions<\/td>\n<td>Continuity file<\/td>\n<td>\u0627\u0644\u062a\u0639\u064a\u064a\u0646 \u0627\u0644\u0635\u062d\u064a\u062d<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0647\u062c\u0631\u0629<\/td>\n<td>Test next-stage channel<\/td>\n<td>Transition record<\/td>\n<td>Revise roadmap<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/MPO-Adapter-Panel-Cassette-1U.jpg\" alt=\"MPO cassette panel that converts trunk fibers to duplex ports\" width=\"1536\" height=\"954\" \/><\/figure>\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0627\u0644\u0627\u0633\u062a\u0646\u0627\u062f \u0625\u0644\u064a\u0647\u0627 \u0639\u0646\u062f \u0625\u0635\u062f\u0627\u0631 \u0623\u0645\u0631 \u0627\u0644\u0634\u0631\u0627\u0621<\/h2>\n<p>\u064a\u062d\u062f\u062f \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u0634\u0648\u0631 \u0627\u0644\u0635\u0627\u062f\u0631 \u0639\u0646 \u0627\u0644\u0644\u062c\u0646\u0629 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0644\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (IEC) \u0623\u0628\u0639\u0627\u062f \u0648\u0627\u062c\u0647\u0629 MPO \u0630\u0627\u062a \u0627\u0644\u0635\u0641\u064a\u0646. \u0627\u0646\u0638\u0631 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/30239\" target=\"_blank\" rel=\"noopener\">\u0648\u0627\u062c\u0647\u0629 MPO \u0630\u0627\u062a \u0627\u0644\u0635\u0641\u064a\u0646 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 IEC 61754-7-2<\/a>.<\/p>\n<p>\u064a\u062a\u0646\u0627\u0648\u0644 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u0634\u0648\u0631 \u0627\u0644\u0635\u0627\u062f\u0631 \u0639\u0646 \u0627\u0644\u0644\u062c\u0646\u0629 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0644\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (IEC) \u0648\u0627\u062c\u0647\u0629 MPO \u0630\u0627\u062a \u0627\u0644\u0635\u0641\u064a\u0646 \u0648\u0639\u0631\u0636 16 \u0644\u064a\u0641\u064b\u0627. \u0627\u0646\u0638\u0631 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/26692\" target=\"_blank\" rel=\"noopener\">\u0648\u0627\u062c\u0647\u0629 MPO \u0630\u0627\u062a \u0639\u0631\u0636 16 \u0644\u064a\u0641\u064b\u0627 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 IEC 61754-7-3<\/a>.<\/p>\n<p>\u064a\u062a\u0646\u0627\u0648\u0644 \u0647\u0630\u0627 \u0627\u0644\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0635\u0627\u062f\u0631 \u0639\u0646 \u0627\u0644\u0644\u062c\u0646\u0629 \u0627\u0644\u062f\u0648\u0644\u064a\u0629 \u0644\u0644\u0643\u0647\u0631\u0628\u0627\u0621 (IEC) \u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0627\u0644\u062a\u0648\u0647\u064a\u0646 \u0648\u0627\u0644\u0642\u0637\u0628\u064a\u0629 \u0648\u0627\u0644\u0637\u0648\u0644 \u0644\u0644\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u0645\u0632\u0648\u062f\u0629 \u0628\u0646\u0647\u0627\u064a\u0627\u062a MPO \u0648\u0627\u0644\u0645\u0631\u0643\u0628\u0629 \u0628\u0627\u0644\u0641\u0639\u0644. \u0627\u0646\u0638\u0631 <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32021\" target=\"_blank\" rel=\"noopener\">\u0625\u062c\u0631\u0627\u0621 \u0627\u062e\u062a\u0628\u0627\u0631 \u0643\u0627\u0628\u0644\u0627\u062a MPO \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 IEC 61280-4-5<\/a>.<\/p>\n<h2>Design recommendation<\/h2>\n<p>Base-8 and Base-12 can both be engineered well. Choose by documented utilisation, available modules, testability and the approved migration sequence.<\/p>\n<ul>\n<li>Audit installed trunk base<\/li>\n<li>Map exact optical lanes<\/li>\n<li>Approve conversion modules<\/li>\n<li>Label mixed systems clearly<\/li>\n<li>Test both current and future configurations<\/li>\n<\/ul>\n<p>\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u062e\u0627\u0635 \u0628\u0645\u0634\u0631\u0648\u0639 \u0645\u0639\u064a\u0646\u060c \u064a\u0631\u062c\u0649 \u0627\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0645\u0648\u0642\u0639 Fenxi <a href=\"https:\/\/www.fenxifiber.com\/ar\/product-category\/%d9%85%d9%88%d8%b5%d9%84-mpo\/\" target=\"_blank\" rel=\"noopener\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0648\u0635\u0644\u0627\u062a MPO<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/ar\/product-category\/%d8%b3%d9%84%d9%83-%d8%aa%d9%88%d8%b5%d9%8a%d9%84-%d8%a7%d9%84%d8%a3%d9%84%d9%8a%d8%a7%d9%81-%d8%a7%d9%84%d8%a8%d8%b5%d8%b1%d9%8a%d8%a9\/%d8%b3%d9%84%d9%83-%d8%aa%d9%88%d8%b5%d9%8a%d9%84-%d8%a7%d9%84%d8%a3%d9%84%d9%8a%d8%a7%d9%81-%d8%a7%d9%84%d8%a8%d8%b5%d8%b1%d9%8a%d8%a9-mpo-mtp\/\" target=\"_blank\" rel=\"noopener\">\u0643\u0627\u0628\u0644\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644 MPO\/MTP<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/ar\/%d9%83%d8%a7%d8%a8%d9%84-%d8%b1%d8%a6%d9%8a%d8%b3%d9%8a-%d9%85%d9%86-%d9%86%d9%88%d8%b9-mpo-mtp-%d8%b3%d8%b9%d8%a9-400-%d8%ac%d8%b1%d8%a7%d9%85\/\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0643\u0627\u0628\u0644\u0627\u062a MPO \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/a>, \u0648 <a href=\"https:\/\/www.fenxifiber.com\/ar\/mpo-polarity-method-a-b-c\/\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u0637\u0631\u0642 \u062a\u062d\u062f\u064a\u062f \u0642\u0637\u0628\u064a\u0629 MPO<\/a>. \u064a\u0631\u062c\u0649 \u0625\u0631\u0633\u0627\u0644 \u0645\u0639\u0644\u0648\u0645\u0627\u062a \u062d\u0648\u0644 \u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641\u0629\u060c \u0648\u0648\u0627\u062c\u0647\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u060c \u0648\u0646\u0648\u0639 \u0627\u0644\u0623\u0644\u064a\u0627\u0641\u060c \u0648\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0643\u0627\u0628\u0644\u060c \u0648\u0627\u0644\u0643\u0645\u064a\u0627\u062a\u060c \u0648\u0631\u0642\u0645 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0645\u062e\u0637\u0637\u060c \u0648\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629. \u0648\u064a\u0645\u0643\u0646 \u0639\u0646\u062f\u0626\u0630\u064d \u0623\u0646 \u062a\u0645\u064a\u0632 \u0627\u0644\u0631\u062f \u0628\u064a\u0646 \u0627\u0644\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0627\u0644\u0648\u0627\u0631\u062f\u0629 \u0641\u064a \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c \u0648\u0627\u0644\u0628\u0646\u0648\u062f \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062a\u0623\u0643\u064a\u062f \u0623\u0648 \u0623\u062f\u0648\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0645\u062e\u0635\u0635\u0629.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0642\u0627\u0631\u0646 \u0628\u064a\u0646 \u0643\u0627\u0628\u0644\u0627\u062a MPO \u0630\u0627\u062a \u0627\u0644\u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u062b\u0645\u0627\u0646\u064a\u0629 \u0648\u0627\u0644\u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u0627\u062b\u0646\u064a \u0639\u0634\u0631 \u0645\u0646 \u062d\u064a\u062b \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0645\u0633\u0627\u0631\u0627\u062a\u060c \u0648\u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0643\u0627\u0633\u064a\u062a\u060c \u0648\u0648\u0627\u062c\u0647\u0627\u062a \u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u0625\u0631\u0633\u0627\u0644 \u0648\u0627\u0644\u0627\u0633\u062a\u0642\u0628\u0627\u0644\u060c \u0648\u0627\u0644\u0642\u0637\u0628\u064a\u0629\u060c \u0648\u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u0631\u062d\u064a\u0644\u060c \u0648\u0627\u062e\u062a\u0628\u0627\u0631\u0627\u062a \u0645\u0627 \u0628\u0639\u062f \u0627\u0644\u062a\u0631\u0643\u064a\u0628.<\/p>","protected":false},"author":1,"featured_media":1135,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1232","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/comments?post=1232"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1232\/revisions"}],"predecessor-version":[{"id":1233,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1232\/revisions\/1233"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/media\/1135"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/media?parent=1232"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/categories?post=1232"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/tags?post=1232"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}