{"id":1246,"date":"2026-10-16T09:02:00","date_gmt":"2026-10-16T09:02:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-lot-acceptance\/"},"modified":"2026-10-02T10:00:48","modified_gmt":"2026-10-02T10:00:48","slug":"plc-splitter-lot-acceptance","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/ar\/plc-splitter-lot-acceptance\/","title":{"rendered":"PLC Splitter Uniformity Directivity and PDL in Lot Acceptance"},"content":{"rendered":"<p><strong>Uniformity, directivity and polarization-dependent loss describe different behaviours and must not be replaced by a single insertion-loss value. Lot acceptance should define the method, wavelengths, sample plan and disposition rule before shipment.<\/strong><\/p>\n<p>Uniformity compares output-port loss spread; directivity concerns unwanted coupling in the reverse direction; PDL describes loss variation with polarization. Values depend on the stated configuration and method. Buyers should request raw port-level data and a product-specific specification rather than transferring limits from an unrelated package or split ratio.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave splitter chip whose outputs require port-level testing\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter uniformity directivity PDL?<\/h2>\n<p>\u0627\u0633\u062a\u062e\u062f\u0645 \u062c\u062f\u0648\u0644 \u0627\u0644\u0642\u0631\u0627\u0631 \u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u0645\u0648\u0636\u0648\u0639 \u0625\u0644\u0649 \u0645\u062f\u062e\u0644\u0627\u062a \u0645\u062d\u062f\u062f\u0629 \u062a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0634\u0631\u0627\u0621 \u0648\u0627\u0644\u062a\u0635\u0645\u064a\u0645 \u0648\u0627\u0644\u0642\u0628\u0648\u0644. \u064a\u062c\u0628 \u0627\u0644\u062a\u062d\u0642\u0642 \u0645\u0646 \u0643\u0644 \u0635\u0641 \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u0641\u0639\u0644\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u0627\u0644\u0645\u0633\u0627\u0631 \u0648\u0627\u0644\u0648\u062c\u0647\u0629\u060c \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0646\u0633\u062e\u0647 \u0645\u0646 \u0643\u062a\u0627\u0644\u0648\u062c \u0639\u0627\u0645.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u0645\u062c\u0627\u0644 \u0627\u062a\u062e\u0627\u0630 \u0627\u0644\u0642\u0631\u0627\u0631<\/th>\n<th>\u0645\u0627 \u0627\u0644\u0630\u064a \u064a\u062c\u0628 \u062a\u062d\u062f\u064a\u062f\u0647<\/th>\n<th>\u0644\u0645\u0627\u0630\u0627 \u0647\u0630\u0627 \u0645\u0647\u0645\u061f<\/th>\n<th>\u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0627\u0644\u0627\u062d\u062a\u0641\u0627\u0638 \u0628\u0647\u0627<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Parameter definition<\/td>\n<td>Formula, direction and units<\/td>\n<td>Prevents inconsistent reports<\/td>\n<td>Controlled specification<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0623\u0637\u0648\u0627\u0644 \u0627\u0644\u0645\u0648\u062c\u064a\u0629<\/td>\n<td>Exact test wavelengths and condition<\/td>\n<td>Results vary by wavelength<\/td>\n<td>Test plan<\/td>\n<\/tr>\n<tr>\n<td>Port coverage<\/td>\n<td>Every output or approved sample<\/td>\n<td>Finds weak channels<\/td>\n<td>Raw port data<\/td>\n<\/tr>\n<tr>\n<td>\u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a<\/td>\n<td>Lot, level and switching rule<\/td>\n<td>Controls inspection risk<\/td>\n<td>Sampling instruction<\/td>\n<\/tr>\n<tr>\n<td>Traceability<\/td>\n<td>Device, lot, instrument and date<\/td>\n<td>Supports investigations<\/td>\n<td>Serialized record<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter uniformity directivity PDL in the Project<\/h2>\n<p>\u062a\u0631\u0628\u0637 \u0639\u0646\u0627\u0635\u0631 \u0627\u0644\u062a\u062d\u0643\u0645 \u0623\u062f\u0646\u0627\u0647 \u0628\u064a\u0646 \u0627\u0644\u0631\u0633\u0645\u060c \u0648\u0627\u0644\u0639\u064a\u0646\u0629\u060c \u0648\u062f\u0641\u0639\u0629 \u0627\u0644\u0625\u0646\u062a\u0627\u062c\u060c \u0648\u0627\u0644\u0646\u062a\u064a\u062c\u0629 \u0627\u0644\u0646\u0647\u0627\u0626\u064a\u0629. \u0648\u0642\u062f \u0635\u064f\u0645\u0645\u062a \u0647\u0630\u0647 \u0627\u0644\u0639\u0646\u0627\u0635\u0631 \u0644\u062a\u0643\u0648\u0646 \u0639\u0645\u0644\u064a\u0629 \u0628\u0634\u0643\u0644 \u0645\u062a\u0639\u0645\u062f: \u0641\u0643\u0644 \u0645\u0646\u0647\u0627 \u064a\u064f\u0646\u0634\u0626 \u0633\u062c\u0644\u0627\u064b \u064a\u0645\u0643\u0646 \u0644\u0641\u0631\u0642 \u0627\u0644\u0645\u0634\u062a\u0631\u064a\u0627\u062a \u0648\u0627\u0644\u0647\u0646\u062f\u0633\u0629 \u0648\u0627\u0644\u0639\u0645\u0644 \u0627\u0644\u0645\u064a\u062f\u0627\u0646\u064a \u0645\u0631\u0627\u062c\u0639\u062a\u0647 \u0644\u0627\u062d\u0642\u064b\u0627.<\/p>\n<h3>Keep parameters separate<\/h3>\n<p>Report insertion loss by port, calculate uniformity from the defined set, and record directivity and PDL under their specified methods. A pass label without the underlying fields is not auditable.<\/p>\n<h3>Freeze methods before results<\/h3>\n<p>Agree wavelengths, launch, connectors, reference procedure and environmental condition in the purchase specification. Do not change a method after viewing a difficult lot.<\/p>\n<h3>Use a declared sampling plan<\/h3>\n<p>Choose the sample size and acceptance rule from the relevant inspection system and contract. AQL is a process for lot disposition, not a promise that every untested unit meets the limit.<\/p>\n<h3>Investigate patterns<\/h3>\n<p>Look for repeated weak port positions, package lots or connector types. Pattern review can find assembly or mapping problems that a simple pass count misses.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter prepared for optical acceptance\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>\u0641\u062d\u0648\u0635\u0627\u062a \u0627\u0644\u0642\u0628\u0648\u0644 \u0648\u0627\u0644\u062a\u0633\u0644\u064a\u0645<\/h2>\n<p>\u064a\u062c\u0628 \u0627\u0644\u0627\u062a\u0641\u0627\u0642 \u0639\u0644\u0649 \u0627\u0644\u0637\u0631\u064a\u0642\u0629 \u0648\u0627\u0644\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0642\u0628\u0644 \u0628\u062f\u0621 \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631. \u0641\u0645\u0646 \u0627\u0644\u0635\u0639\u0628 \u0627\u0644\u0627\u0633\u062a\u0641\u0627\u062f\u0629 \u0645\u0646 \u0623\u064a \u0646\u062a\u064a\u062c\u0629 \u0644\u0627 \u064a\u0648\u062c\u062f \u0644\u0647\u0627 \u0645\u0633\u0624\u0648\u0644 \u0645\u062d\u062f\u062f \u0639\u0646 \u0627\u0644\u0633\u062c\u0644 \u0623\u0648 \u0625\u062c\u0631\u0627\u0621 \u0645\u062d\u062f\u062f \u0641\u064a \u062d\u0627\u0644\u0629 \u0627\u0644\u0641\u0634\u0644\u060c \u0648\u0630\u0644\u0643 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u0625\u0641\u0631\u0627\u062c \u0639\u0646 \u0627\u0644\u0634\u062d\u0646\u0629 \u0623\u0648 \u0628\u062f\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u062a\u062d\u0642\u0642<\/th>\n<th>\u0627\u0644\u0637\u0631\u064a\u0642\u0629<\/th>\n<th>\u0627\u0644\u0633\u062c\u0644<\/th>\n<th>\u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0641\u0634\u0644<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0627\u0644\u0637\u0631\u064a\u0642\u0629<\/td>\n<td>Compare procedure to specification<\/td>\n<td>Signed setup<\/td>\n<td>Retest with correct method<\/td>\n<\/tr>\n<tr>\n<td>Port data<\/td>\n<td>Review every required channel<\/td>\n<td>Raw table<\/td>\n<td>Quarantine missing data<\/td>\n<\/tr>\n<tr>\n<td>Calculations<\/td>\n<td>Recalculate uniformity and summaries<\/td>\n<td>QA worksheet<\/td>\n<td>Correct report<\/td>\n<\/tr>\n<tr>\n<td>\u0623\u062e\u0630 \u0627\u0644\u0639\u064a\u0646\u0627\u062a<\/td>\n<td>Verify lot and sample identities<\/td>\n<td>Sampling record<\/td>\n<td>Resample only by rule<\/td>\n<\/tr>\n<tr>\n<td>Disposition<\/td>\n<td>Record accept, reject or concession<\/td>\n<td>Decision log<\/td>\n<td>Contain rejected lot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats linked to lot traceability\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0648\u0627\u0644\u0623\u062f\u0644\u0629 \u0627\u0644\u062a\u064a \u064a\u062c\u0628 \u0627\u0644\u0627\u0633\u062a\u0646\u0627\u062f \u0625\u0644\u064a\u0647\u0627 \u0639\u0646\u062f \u0625\u0635\u062f\u0627\u0631 \u0623\u0645\u0631 \u0627\u0644\u0634\u0631\u0627\u0621<\/h2>\n<p>\u062a\u064f\u062f\u0631\u062c \u0634\u0631\u0643\u0629 \u0643\u0648\u0631\u0646\u064a\u0646\u063a \u062a\u0646\u0633\u064a\u0642\u0627\u062a \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0648\u0627\u0644\u0648\u062d\u062f\u0627\u062a \u0648\u0627\u0644\u0631\u0641\u0648\u0641\u060c \u0648\u062a\u062d\u062f\u062f \u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062a\u0623\u0647\u064a\u0644 \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u0639\u064a\u0627\u0631 GR-1209\/1221 \u0644\u0645\u062c\u0645\u0648\u0639\u062a\u0647\u0627 \u0645\u0646 \u0645\u0642\u0633\u0645\u0627\u062a PLC. \u0627\u0646\u0638\u0631 <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">\u0645\u0631\u062c\u0639 \u062a\u0623\u0647\u064a\u0644 \u0645\u0642\u0633\u0645\u0627\u062a \u0634\u0631\u0643\u0629 \u0643\u0648\u0631\u0646\u064a\u0646\u063a \u0628\u064a \u0625\u0644 \u0633\u064a<\/a>.<\/p>\n<p>The 2026 edition defines AQL-indexed lot-by-lot attribute-sampling schemes and switching rules. See <a href=\"https:\/\/www.iso.org\/standard\/2859-1\" target=\"_blank\" rel=\"noopener\">ISO 2859-1:2026 AQL sampling standard<\/a>.<\/p>\n<p>ISO 28590 gives guidance on selecting an inspection system from the ISO 2859 family. See <a href=\"https:\/\/www.iso.org\/standard\/64622.html\" target=\"_blank\" rel=\"noopener\">ISO 28590 acceptance-sampling overview<\/a>.<\/p>\n<h2>Acceptance checklist<\/h2>\n<p>A useful splitter certificate connects defined parameters to raw port data, equipment, sample identity and a pre-agreed lot decision. Keep all of those records under the same part revision.<\/p>\n<ul>\n<li>Define each parameter<\/li>\n<li>Name wavelengths and method<\/li>\n<li>Retain port-level results<\/li>\n<li>Use a declared sample plan<\/li>\n<li>Control retest and concession decisions<\/li>\n<\/ul>\n<p>\u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631 \u062e\u0627\u0635 \u0628\u0645\u0634\u0631\u0648\u0639 \u0645\u0639\u064a\u0646\u060c \u064a\u0631\u062c\u0649 \u0627\u0644\u0627\u0637\u0644\u0627\u0639 \u0639\u0644\u0649 \u0645\u0648\u0642\u0639 Fenxi <a href=\"https:\/\/www.fenxifiber.com\/ar\/product-category\/%d9%85%d9%82%d8%b3%d9%90%d9%91%d9%85-%d8%a7%d9%84%d8%a3%d9%84%d9%8a%d8%a7%d9%81-%d8%a7%d9%84%d8%a8%d8%b5%d8%b1%d9%8a%d8%a9\/\" target=\"_blank\" rel=\"noopener\">\u0645\u062c\u0645\u0648\u0639\u0629 \u0645\u0642\u0633\u0645\u0627\u062a \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0627\u0644\u0636\u0648\u0626\u064a\u0629<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/ar\/product\/%d9%85%d9%82%d8%b3%d9%90%d9%91%d9%85-%d8%a7%d9%84%d8%a3%d9%84%d9%8a%d8%a7%d9%81-%d8%a7%d9%84%d8%b6%d9%88%d8%a6%d9%8a%d8%a9-sc-apc-116-%d9%85%d9%82%d8%b3%d9%90%d9%91%d9%85-%d8%a7%d9%84%d8%a3%d9%84-2\/\" target=\"_blank\" rel=\"noopener\">\u0645\u0642\u0633\u0645 1\u00d716 SC APC PLC<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/ar\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">\u0645\u0642\u0627\u0631\u0646\u0629 \u0628\u064a\u0646 \u0645\u0642\u0633\u0645\u064a PLC \u0648FBT<\/a>, \u0648 <a href=\"https:\/\/www.fenxifiber.com\/ar\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">\u062f\u0644\u064a\u0644 \u062a\u062e\u0637\u064a\u0637 \u0645\u064a\u0632\u0627\u0646\u064a\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u0634\u0628\u0643\u0629 PON<\/a>. \u064a\u0631\u062c\u0649 \u0625\u0631\u0633\u0627\u0644 \u0645\u0639\u0644\u0648\u0645\u0627\u062a \u062d\u0648\u0644 \u0627\u0644\u0633\u0648\u0642 \u0627\u0644\u0645\u0633\u062a\u0647\u062f\u0641\u0629\u060c \u0648\u0648\u0627\u062c\u0647\u0627\u062a \u0627\u0644\u062a\u0648\u0635\u064a\u0644\u060c \u0648\u0646\u0648\u0639 \u0627\u0644\u0623\u0644\u064a\u0627\u0641\u060c \u0648\u062a\u0631\u0643\u064a\u0628 \u0627\u0644\u0643\u0627\u0628\u0644\u060c \u0648\u0627\u0644\u0643\u0645\u064a\u0627\u062a\u060c \u0648\u0631\u0642\u0645 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u0645\u062e\u0637\u0637\u060c \u0648\u0633\u062c\u0644\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629. \u0648\u064a\u0645\u0643\u0646 \u0639\u0646\u062f\u0626\u0630\u064d \u0623\u0646 \u062a\u0645\u064a\u0632 \u0627\u0644\u0631\u062f \u0628\u064a\u0646 \u0627\u0644\u062e\u064a\u0627\u0631\u0627\u062a \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0627\u0644\u0648\u0627\u0631\u062f\u0629 \u0641\u064a \u0627\u0644\u0643\u062a\u0627\u0644\u0648\u062c \u0648\u0627\u0644\u0628\u0646\u0648\u062f \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062a\u0623\u0643\u064a\u062f \u0623\u0648 \u0623\u062f\u0648\u0627\u062a \u062a\u0635\u0646\u064a\u0639 \u0645\u062e\u0635\u0635\u0629.<\/p>","protected":false},"excerpt":{"rendered":"<p>Define PLC splitter uniformity, directivity, and PDL for lot acceptance with agreed methods, wavelengths, port-level data, sampling, retest rules, and traceability.<\/p>","protected":false},"author":1,"featured_media":1130,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1246","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/comments?post=1246"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1246\/revisions"}],"predecessor-version":[{"id":1247,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/posts\/1246\/revisions\/1247"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/media\/1130"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/media?parent=1246"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/categories?post=1246"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/ar\/wp-json\/wp\/v2\/tags?post=1246"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}