FC/UPC-ST/UPC-50/125-DX Multimode-Glasfaser-Patchkabel

Die FC/UPC–ST/UPC-50/125-DX is a rugged duplex multimode fiber patch cord created for environments where secure locking, signal stability, and mechanical reliability matter. It links FC-threaded ports zu ST bayonet-style connectors, making it a practical solution for telecom rooms, industrial networks, laboratories, and campus fiber systems.

Gebaut mit 50/125 μm multimode fiber, this patch cord is optimized for 850 nm and 1300 nm wavelengths—the backbone of short-range and mid-range optical communication.

Beschreibung

Designed for Stability in Demanding Installations

Both FC and ST connectors are known for their positive locking mechanisms. The FC end uses a threaded coupling to prevent micro-movement, while the ST end locks with a twist-and-click bayonet, making the cable resistant to vibration and accidental disconnects.

Mit UPC-Polieren on both ends, fiber cores make smooth physical contact, keeping insertion loss low and return loss stable, which is especially important for test and monitoring systems.


Technical Profile

Parameter FC/UPC–ST/UPC-50/125-DX
Faser-Typ Multimode 50/125 μm
Faser-Modus OM2 / OM3 compatible
Konfiguration Duplex (DX)
Anschluss A FC / UPC
Anschluss B ST / UPC
Betriebswellenlänge 850 nm / 1300 nm
Einfügedämpfung ≤ 0,30 dB
Rückflussdämpfung ≥ 30 dB
Kabelmantel LSZH oder PVC
Zugfestigkeit ≥ 200 N
Dauerhaftigkeit ≥ 1,000 mating cycles
Betriebstemperatur -10 °C bis +70 °C
Normen IEC, TIA-568, RoHS, REACH

Real-World Performance

Verwendung von 50/125 µm Multimode-Faser at 850 nm, this cable supports:

  • 10G Ethernet up to 300 m (OM3)

  • 40G and 100G multimode links up to 100–150 m

This makes it suitable for:

  • Industrial Ethernet networks

  • Backbones für Campus und Gebäude

  • Fiber test equipment

  • Optical distribution frames

  • Security and monitoring systems


Built for Long-Term Reliability

Each patch cord is assembled with high-precision ceramic ferrules and inspected using automated interferometry and insertion-loss testing. This ensures consistent optical alignment und repeatable performance over thousands of connection cycles, even in high-traffic patching environments.

Die Option LSZH-Jacke further supports installations in data centers and public buildings where fire safety and low smoke emission sind erforderlich.


Fachliche Fragen und Antworten

Q1: What makes FC and ST connectors good for industrial use?
Both use locking mechanisms that resist vibration and accidental unplugging, making them ideal for harsh or active environments.

Q2: Is this cable suitable for 10G Ethernet?
Yes. With OM3-grade 50/125 fiber, it supports 10G links up to 300 meters at 850 nm.

Q3: Can this cable be used with test instruments?
Absolutely. FC connectors are common on OTDRs and optical power meters, while ST is widely used on distribution frames.

F4: Beeinträchtigt das Polieren von UPC die Signalqualität?
Yes. UPC provides low insertion loss and stable return loss (≥30 dB), which improves measurement accuracy and transmission reliability.

Bewertungen

Es sind noch keine Bewertungen vorhanden.

Seien Sie der Erste, der “FC/UPC–ST/UPC-50/125-DX Multimode Fiber Optic Patch Cord” bewertet.”

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert

Erhalten Sie kostenlos Produktlösungen

Angebot einholen