Beschreibung
Wesentliche Merkmale
-
Adjustable 2.0 mm / 3.0 mm boot options — compatible with standard fiber cable diameters.
-
Angled physical contact (APC) polish — superior return loss performance (> 60 dB typical).
-
Geringe Einfügungsdämpfung for optimized signal throughput.
-
Precision zirconia ferrule for accurate fiber alignment.
-
Überwurfmutter aus Metall mit Gewinde for robust connection engagement.
-
Wide operating temperature range for field resilience.
-
Optional boot colors to match deployment environments.
Technische Daten
Optische Leistung
| Parameter | Typischer Wert |
|---|---|
| Einfügungsdämpfung (APC) | ≤ 0,25 dB |
| Rückflussdämpfung (APC) | ≥ 60 dB |
| Betriebswellenlänge | 1310 nm, 1550 nm |
| Faser-Modus | Monomode (9/125 µm) |
| Dauerhaftigkeit | > 1000 matings |
(Data representative of typical industry values for FC APC connectors)
Mechanik und Umwelt
| Merkmal | Spezifikation |
|---|---|
| Kabel-Durchmesser | 2,0 mm / 3,0 mm |
| Material der Aderendhülse | Keramik (Zirkoniumdioxid) |
| Betriebstemperatur | -40 °C to +80 °C |
| Kupplungsart | Threaded FC nut |
| Connector Boot Colors | Green (standard APC), others optional |
(Industry standard compliance and environmental tolerances)
Typische Anwendungen
-
Telecommunications networks – high-speed signal transmission with low reflection.
-
PON / FTTH deployments – fiber access connections requiring robust reliability.
-
CATV systems – long-distance signal distribution.
-
LAN/WAN infrastructures – patch panels and fiber runs in enterprise networks.
-
Test & measurement equipment interfaces – precise optical alignment.
Fachliche Fragen und Antworten
Q1: What does APC mean and why is it important?
A1: APC steht für Abgewinkelter physischer Kontakt, a type of fiber endface polish where the ferrule endface is angled (typically 8°). This reduces back-reflection and improves return loss, which is critical for high-performance single-mode systems and high bandwidth networks.
Q2: Can FC APC connectors be used in outdoor fiber deployments?
A2: Yes. FC APC connectors with ruggedized metal coupling and wide temperature range are suitable for protected outdoor and industrial environments when properly housed and strain-relieved.
Q3: What’s the difference between FC/APC and FC/UPC?
A3: Both are FC connectors; APC has an angled polish that gives much higher return loss (typically ≥ 60 dB) than UPC (≤ 55 dB), making APC better for systems sensitive to reflection. They are not directly compatible.





Bewertungen