{"id":1240,"date":"2026-10-15T04:19:00","date_gmt":"2026-10-15T04:19:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-package-types\/"},"modified":"2026-10-02T09:59:33","modified_gmt":"2026-10-02T09:59:33","slug":"plc-splitter-package-types","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/de\/plc-splitter-package-types\/","title":{"rendered":"PLC-Splitter-Geh\u00e4usetypen: Bare Mini, ABS, LGX und Rack"},"content":{"rendered":"<p><strong>Choose the PLC splitter package after the cabinet, closure or rack interface is fixed. The optical circuit may be similar across formats, but tube diameter, pigtail exit, connector presentation, mounting method and technician access determine whether the assembly can be installed and serviced.<\/strong><\/p>\n<p>Bare-fibre and steel-tube units suit protected internal integration; ABS modules add mechanical protection; LGX, cassette and rack formats provide connectorized presentation and mounting features. Package names are not universal dimensional standards, so procurement should request a controlled outline drawing and test a production-representative sample in the target enclosure.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats for enclosure and rack selection\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter package types?<\/h2>\n<p>Verwenden Sie die Entscheidungstabelle, um das Thema in kontrollierte Eingaben f\u00fcr Einkauf, Konstruktion und Abnahme umzuwandeln. Jede Zeile sollte anhand der tats\u00e4chlichen Ausr\u00fcstung, der Route und der Zielvorgaben \u00fcberpr\u00fcft werden, anstatt aus einem allgemeinen Katalog kopiert zu werden.<\/p>\n<table>\n<thead>\n<tr>\n<th>Entscheidungsbereich<\/th>\n<th>Was ist anzugeben?<\/th>\n<th>Warum das wichtig ist<\/th>\n<th>Aufzubewahrende Unterlagen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Installation location<\/td>\n<td>Closure, wall box, cabinet or rack<\/td>\n<td>Defines protection and mounting needs<\/td>\n<td>Approved enclosure drawing<\/td>\n<\/tr>\n<tr>\n<td>Fibre presentation<\/td>\n<td>Bare fibre, pigtails or adapters<\/td>\n<td>Changes splicing and patching work<\/td>\n<td>Port and tail schedule<\/td>\n<\/tr>\n<tr>\n<td>Mechanical envelope<\/td>\n<td>Body, bend exits and mounting points<\/td>\n<td>Controls fit and routing<\/td>\n<td>Dimensioned outline<\/td>\n<\/tr>\n<tr>\n<td>Zugang zum Service<\/td>\n<td>Cleaning, replacement and labels<\/td>\n<td>Affects restoration time<\/td>\n<td>Populated enclosure trial<\/td>\n<\/tr>\n<tr>\n<td>Optical evidence<\/td>\n<td>Port-level loss and uniformity<\/td>\n<td>Links package to tested device<\/td>\n<td>Testbericht in Serienform<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter package types in the Project<\/h2>\n<p>Die folgenden Steuerelemente verkn\u00fcpfen die Zeichnung, das Muster, die Produktionscharge und das Installationsergebnis miteinander. Sie sind bewusst praxisorientiert gestaltet: Jedes einzelne erzeugt einen Datensatz, den die Teams aus den Bereichen Beschaffung, Technik und Au\u00dfendienst sp\u00e4ter einsehen k\u00f6nnen.<\/p>\n<h3>Design from the enclosure inward<\/h3>\n<p>Reserve space for the package, tails, connectors, splice protectors and minimum routing radius. A module that fits an empty box may still block the cover or adjacent adapters after cabling.<\/p>\n<h3>Separate optical and mechanical requirements<\/h3>\n<p>State the split configuration and optical acceptance separately from package dimensions, cable lengths, connector types and mounting hardware. This prevents a correct optical device from arriving in the wrong mechanical format.<\/p>\n<h3>Approve the installed sample<\/h3>\n<p>Load one representative enclosure with the intended splitter, adapters and pigtails. Verify identification, cleaning access, tail routing and replacement sequence before volume release.<\/p>\n<h3>Control package substitutions<\/h3>\n<p>Require notification when the housing, exit boot, cable or connector supplier changes. Recheck fit and optical records against the approved drawing and sample.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave circuit splitter chip before packaging\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>Abnahme- und \u00dcbergabekontrollen<\/h2>\n<p>Legen Sie die Vorgehensweise und die weitere Vorgehensweise vor Beginn der Tests fest. Ein Ergebnis ohne festgelegten Verantwortlichen f\u00fcr die Dokumentation oder ohne festgelegte Ma\u00dfnahmen im Fehlerfall l\u00e4sst sich bei der Freigabe f\u00fcr den Versand oder bei der Inbetriebnahme nur schwer nutzen.<\/p>\n<table>\n<thead>\n<tr>\n<th>Siehe<\/th>\n<th>Verfahren<\/th>\n<th>Datensatz<\/th>\n<th>Ma\u00dfnahme bei Ausfall<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Outline fit<\/td>\n<td>Install in target enclosure<\/td>\n<td>Fit photos and dimensions<\/td>\n<td>Revise package or enclosure<\/td>\n<\/tr>\n<tr>\n<td>Tail routing<\/td>\n<td>Route every output<\/td>\n<td>Routing record<\/td>\n<td>Correct length or exit<\/td>\n<\/tr>\n<tr>\n<td>Port identity<\/td>\n<td>Trace input and outputs<\/td>\n<td>Label and continuity map<\/td>\n<td>Relabel before shipment<\/td>\n<\/tr>\n<tr>\n<td>Optical test<\/td>\n<td>Measure each required port<\/td>\n<td>Serialized report<\/td>\n<td>Quarantine failing unit<\/td>\n<\/tr>\n<tr>\n<td>Testnutzung<\/td>\n<td>Clean and replace sample<\/td>\n<td>Technician sign-off<\/td>\n<td>Improve access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter used in an FTTH distribution point\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>Standards und Belege zur Untermauerung der Bestellung<\/h2>\n<p>Corning listet Komponenten-, Modul- und Rack-Formate auf und gibt an, dass sein PLC-Splitter-Sortiment die GR-1209\/1221-Zertifizierung erf\u00fcllt. Siehe <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">Referenz zur Qualifizierung von Splittern von Corning PLC<\/a>.<\/p>\n<p>Das Dokument aus dem Jahr 2025 beschreibt GPON, XG(S)-PON, 50G-PON sowie Referenzwerte zur Koexistenz in Zugangsnetzen. Siehe <a href=\"https:\/\/www.itu.int\/epublications\/en\/publication\/itu-t-gstp-bain-2025-03-broadband-access-and-in-premises-networks\" target=\"_blank\" rel=\"noopener\">Technisches Papier der ITU zum Breitbandzugang<\/a>.<\/p>\n<p>Die g\u00fcltige Empfehlung von 2024 definiert Kategorien biegeunempfindlicher Singlemode-Fasern und deren Anwendungsbereich. Siehe <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.657-202408-I\" target=\"_blank\" rel=\"noopener\">ITU-T G.657 \u2013 Empfehlung zu biegeunempfindlichen Glasfasern<\/a>.<\/p>\n<h2>RFQ checklist<\/h2>\n<p>Package selection is an enclosure-engineering decision as well as an optical purchase. Freeze the outline, fibre presentation, label scheme and port-level test record in the same approval package.<\/p>\n<ul>\n<li>Name the target enclosure<\/li>\n<li>Request a controlled outline drawing<\/li>\n<li>Specify tail and connector presentation<\/li>\n<li>Approve a populated sample<\/li>\n<li>Link each serial number to optical results<\/li>\n<\/ul>\n<p>F\u00fcr ein projektspezifisches Angebot sehen Sie sich bitte das Angebot von Fenxi an <a href=\"https:\/\/www.fenxifiber.com\/de\/product-category\/faseroptischer-splitter\/\" target=\"_blank\" rel=\"noopener\">Sortiment an Glasfaserteiler<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/de\/product\/faseroptischer-splitter-sc-apc-116-verlustarmer-plc-faserverteiler\/\" target=\"_blank\" rel=\"noopener\">1\u00d716 SC-APC-PLC-Splitter<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/de\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">Vergleich zwischen PLC- und FBT-Splitter<\/a>, und <a href=\"https:\/\/www.fenxifiber.com\/de\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">Leitfaden zur Planung des PON-Leistungsbudgets<\/a>. Bitte geben Sie den Zielmarkt, die Anschlussschnittstellen, den Fasertyp, den Kabelaufbau, die St\u00fcckzahlen, die Zeichnungsversion und die erforderlichen Pr\u00fcfprotokolle an. In der Antwort werden dann die Standardoptionen aus dem Katalog von den Artikeln unterschieden, die einer Best\u00e4tigung bed\u00fcrfen oder f\u00fcr die Sonderwerkzeuge erforderlich sind.<\/p>","protected":false},"excerpt":{"rendered":"<p>Vergleichen Sie Splitter-Baugruppen aus blankem Material, Stahlrohr, ABS, LGX, Kassetten- und Rack-PLC-Ausf\u00fchrung hinsichtlich Einbau in Geh\u00e4use, Steckverbinderzugang, Kabelf\u00fchrung, Schutz, Pr\u00fcfung und Beschriftung.<\/p>","protected":false},"author":1,"featured_media":1131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/comments?post=1240"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1240\/revisions"}],"predecessor-version":[{"id":1241,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1240\/revisions\/1241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media\/1131"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media?parent=1240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/categories?post=1240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/tags?post=1240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}