{"id":1246,"date":"2026-10-16T09:02:00","date_gmt":"2026-10-16T09:02:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-lot-acceptance\/"},"modified":"2026-10-02T10:00:48","modified_gmt":"2026-10-02T10:00:48","slug":"plc-splitter-lot-acceptance","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/de\/plc-splitter-lot-acceptance\/","title":{"rendered":"PLC Splitter Uniformity Directivity and PDL in Lot Acceptance"},"content":{"rendered":"<p><strong>Uniformity, directivity and polarization-dependent loss describe different behaviours and must not be replaced by a single insertion-loss value. Lot acceptance should define the method, wavelengths, sample plan and disposition rule before shipment.<\/strong><\/p>\n<p>Uniformity compares output-port loss spread; directivity concerns unwanted coupling in the reverse direction; PDL describes loss variation with polarization. Values depend on the stated configuration and method. Buyers should request raw port-level data and a product-specific specification rather than transferring limits from an unrelated package or split ratio.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave splitter chip whose outputs require port-level testing\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter uniformity directivity PDL?<\/h2>\n<p>Verwenden Sie die Entscheidungstabelle, um das Thema in kontrollierte Eingaben f\u00fcr Einkauf, Konstruktion und Abnahme umzuwandeln. Jede Zeile sollte anhand der tats\u00e4chlichen Ausr\u00fcstung, der Route und der Zielvorgaben \u00fcberpr\u00fcft werden, anstatt aus einem allgemeinen Katalog kopiert zu werden.<\/p>\n<table>\n<thead>\n<tr>\n<th>Entscheidungsbereich<\/th>\n<th>Was ist anzugeben?<\/th>\n<th>Warum das wichtig ist<\/th>\n<th>Aufzubewahrende Unterlagen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Parameter definition<\/td>\n<td>Formula, direction and units<\/td>\n<td>Prevents inconsistent reports<\/td>\n<td>Controlled specification<\/td>\n<\/tr>\n<tr>\n<td>Wellenl\u00e4ngen<\/td>\n<td>Exact test wavelengths and condition<\/td>\n<td>Results vary by wavelength<\/td>\n<td>Test plan<\/td>\n<\/tr>\n<tr>\n<td>Port coverage<\/td>\n<td>Every output or approved sample<\/td>\n<td>Finds weak channels<\/td>\n<td>Raw port data<\/td>\n<\/tr>\n<tr>\n<td>Stichproben<\/td>\n<td>Lot, level and switching rule<\/td>\n<td>Controls inspection risk<\/td>\n<td>Sampling instruction<\/td>\n<\/tr>\n<tr>\n<td>Traceability<\/td>\n<td>Device, lot, instrument and date<\/td>\n<td>Supports investigations<\/td>\n<td>Serialized record<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter uniformity directivity PDL in the Project<\/h2>\n<p>Die folgenden Steuerelemente verkn\u00fcpfen die Zeichnung, das Muster, die Produktionscharge und das Installationsergebnis miteinander. Sie sind bewusst praxisorientiert gestaltet: Jedes einzelne erzeugt einen Datensatz, den die Teams aus den Bereichen Beschaffung, Technik und Au\u00dfendienst sp\u00e4ter einsehen k\u00f6nnen.<\/p>\n<h3>Keep parameters separate<\/h3>\n<p>Report insertion loss by port, calculate uniformity from the defined set, and record directivity and PDL under their specified methods. A pass label without the underlying fields is not auditable.<\/p>\n<h3>Freeze methods before results<\/h3>\n<p>Agree wavelengths, launch, connectors, reference procedure and environmental condition in the purchase specification. Do not change a method after viewing a difficult lot.<\/p>\n<h3>Use a declared sampling plan<\/h3>\n<p>Choose the sample size and acceptance rule from the relevant inspection system and contract. AQL is a process for lot disposition, not a promise that every untested unit meets the limit.<\/p>\n<h3>Investigate patterns<\/h3>\n<p>Look for repeated weak port positions, package lots or connector types. Pattern review can find assembly or mapping problems that a simple pass count misses.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter prepared for optical acceptance\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>Abnahme- und \u00dcbergabekontrollen<\/h2>\n<p>Legen Sie die Vorgehensweise und die weitere Vorgehensweise vor Beginn der Tests fest. Ein Ergebnis ohne festgelegten Verantwortlichen f\u00fcr die Dokumentation oder ohne festgelegte Ma\u00dfnahmen im Fehlerfall l\u00e4sst sich bei der Freigabe f\u00fcr den Versand oder bei der Inbetriebnahme nur schwer nutzen.<\/p>\n<table>\n<thead>\n<tr>\n<th>Siehe<\/th>\n<th>Verfahren<\/th>\n<th>Datensatz<\/th>\n<th>Ma\u00dfnahme bei Ausfall<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Verfahren<\/td>\n<td>Compare procedure to specification<\/td>\n<td>Signed setup<\/td>\n<td>Retest with correct method<\/td>\n<\/tr>\n<tr>\n<td>Port data<\/td>\n<td>Review every required channel<\/td>\n<td>Raw table<\/td>\n<td>Quarantine missing data<\/td>\n<\/tr>\n<tr>\n<td>Calculations<\/td>\n<td>Recalculate uniformity and summaries<\/td>\n<td>QA worksheet<\/td>\n<td>Correct report<\/td>\n<\/tr>\n<tr>\n<td>Stichproben<\/td>\n<td>Verify lot and sample identities<\/td>\n<td>Sampling record<\/td>\n<td>Resample only by rule<\/td>\n<\/tr>\n<tr>\n<td>Disposition<\/td>\n<td>Record accept, reject or concession<\/td>\n<td>Decision log<\/td>\n<td>Contain rejected lot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats linked to lot traceability\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>Standards und Belege zur Untermauerung der Bestellung<\/h2>\n<p>Corning listet Komponenten-, Modul- und Rack-Formate auf und gibt an, dass sein PLC-Splitter-Sortiment die GR-1209\/1221-Zertifizierung erf\u00fcllt. Siehe <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">Referenz zur Qualifizierung von Splittern von Corning PLC<\/a>.<\/p>\n<p>The 2026 edition defines AQL-indexed lot-by-lot attribute-sampling schemes and switching rules. See <a href=\"https:\/\/www.iso.org\/standard\/2859-1\" target=\"_blank\" rel=\"noopener\">ISO 2859-1:2026 AQL sampling standard<\/a>.<\/p>\n<p>ISO 28590 gives guidance on selecting an inspection system from the ISO 2859 family. See <a href=\"https:\/\/www.iso.org\/standard\/64622.html\" target=\"_blank\" rel=\"noopener\">ISO 28590 acceptance-sampling overview<\/a>.<\/p>\n<h2>Acceptance checklist<\/h2>\n<p>A useful splitter certificate connects defined parameters to raw port data, equipment, sample identity and a pre-agreed lot decision. Keep all of those records under the same part revision.<\/p>\n<ul>\n<li>Define each parameter<\/li>\n<li>Name wavelengths and method<\/li>\n<li>Retain port-level results<\/li>\n<li>Use a declared sample plan<\/li>\n<li>Control retest and concession decisions<\/li>\n<\/ul>\n<p>F\u00fcr ein projektspezifisches Angebot sehen Sie sich bitte das Angebot von Fenxi an <a href=\"https:\/\/www.fenxifiber.com\/de\/product-category\/faseroptischer-splitter\/\" target=\"_blank\" rel=\"noopener\">Sortiment an Glasfaserteiler<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/de\/product\/faseroptischer-splitter-sc-apc-116-verlustarmer-plc-faserverteiler\/\" target=\"_blank\" rel=\"noopener\">1\u00d716 SC-APC-PLC-Splitter<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/de\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">Vergleich zwischen PLC- und FBT-Splitter<\/a>, und <a href=\"https:\/\/www.fenxifiber.com\/de\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">Leitfaden zur Planung des PON-Leistungsbudgets<\/a>. Bitte geben Sie den Zielmarkt, die Anschlussschnittstellen, den Fasertyp, den Kabelaufbau, die St\u00fcckzahlen, die Zeichnungsversion und die erforderlichen Pr\u00fcfprotokolle an. In der Antwort werden dann die Standardoptionen aus dem Katalog von den Artikeln unterschieden, die einer Best\u00e4tigung bed\u00fcrfen oder f\u00fcr die Sonderwerkzeuge erforderlich sind.<\/p>","protected":false},"excerpt":{"rendered":"<p>Define PLC splitter uniformity, directivity, and PDL for lot acceptance with agreed methods, wavelengths, port-level data, sampling, retest rules, and traceability.<\/p>","protected":false},"author":1,"featured_media":1130,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1246","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/comments?post=1246"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1246\/revisions"}],"predecessor-version":[{"id":1247,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/posts\/1246\/revisions\/1247"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media\/1130"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media?parent=1246"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/categories?post=1246"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/tags?post=1246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}