{"id":873,"date":"2026-02-04T02:55:05","date_gmt":"2026-02-04T02:55:05","guid":{"rendered":"https:\/\/www.fenxifiber.com\/?post_type=product&#038;p=873"},"modified":"2026-02-05T02:32:47","modified_gmt":"2026-02-05T02:32:47","slug":"lc-apc-2-0mm-duplex-singlemode","status":"publish","type":"product","link":"https:\/\/www.fenxifiber.com\/de\/product\/lc-apc-2-0mm-duplex-singlemode\/","title":{"rendered":"LC APC 2.0mm Duplex Singlemode"},"content":{"rendered":"<h3 data-start=\"731\" data-end=\"777\">Duplex APC f\u00fcr echte Zwei-Wege-\u00dcbertragung<\/h3>\n<p data-start=\"779\" data-end=\"893\">Im Gegensatz zu Simplex-Jumpern bleiben bei Duplex-LC-Steckern <strong data-start=\"829\" data-end=\"868\">Tx- und Rx-Fasern permanent gepaart<\/strong>, die f\u00fcr die Durchf\u00fchrung des Programms unerl\u00e4sslich ist:<\/p>\n<ul data-start=\"895\" data-end=\"988\">\n<li data-start=\"895\" data-end=\"920\">\n<p data-start=\"897\" data-end=\"920\">OLT \u2194 ONU-Verbindungen<\/p>\n<\/li>\n<li data-start=\"921\" data-end=\"953\">\n<p data-start=\"923\" data-end=\"953\">Backbone-Verbindungen zwischen Racks<\/p>\n<\/li>\n<li data-start=\"954\" data-end=\"988\">\n<p data-start=\"956\" data-end=\"988\">Aktive optische Ger\u00e4teanschl\u00fcsse<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"990\" data-end=\"1088\">In Schalttafeln mit hoher Packungsdichte verringern Duplex-APC-Jumper au\u00dferdem Verwechslungen der Polarit\u00e4t und beschleunigen die Wartung.<\/p>\n<hr data-start=\"1090\" data-end=\"1093\" \/>\n<h3 data-start=\"1095\" data-end=\"1141\">2,0 mm - die richtige Gr\u00f6\u00dfe f\u00fcr Live-Netzwerke<\/h3>\n<p data-start=\"1143\" data-end=\"1435\">Ein PON- oder Backbone-Jumper ist st\u00e4ndig in Betrieb.<br data-start=\"1196\" data-end=\"1199\" \/>Es wird in OLT-Karten eingesteckt, durch Kabelmanager gef\u00fchrt und manchmal zu Testzwecken entfernt.<br data-start=\"1294\" data-end=\"1297\" \/>Deshalb wird in diesem Modell ein <strong data-start=\"1327\" data-end=\"1374\">2,0 mm Mantel statt 0,9 mm Pigtail-Faser<\/strong> - Sie bietet <strong data-start=\"1389\" data-end=\"1434\">echte Zugentlastung ohne zu versteifen<\/strong>.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1437\" data-end=\"1632\">\n<thead data-start=\"1437\" data-end=\"1473\">\n<tr data-start=\"1437\" data-end=\"1473\">\n<th class=\"\" data-start=\"1437\" data-end=\"1450\" data-col-size=\"sm\">Kabelgr\u00f6\u00dfe<\/th>\n<th class=\"\" data-start=\"1450\" data-end=\"1473\" data-col-size=\"sm\">Wozu es gut ist<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1508\" data-end=\"1632\">\n<tr data-start=\"1508\" data-end=\"1541\">\n<td data-start=\"1508\" data-end=\"1516\" data-col-size=\"sm\">0,9 mm<\/td>\n<td data-start=\"1516\" data-end=\"1541\" data-col-size=\"sm\">Splei\u00dfen im Inneren von Schalen<\/td>\n<\/tr>\n<tr data-start=\"1542\" data-end=\"1593\">\n<td data-start=\"1542\" data-end=\"1554\" data-col-size=\"sm\"><strong data-start=\"1544\" data-end=\"1553\">2,0 mm<\/strong><\/td>\n<td data-start=\"1554\" data-end=\"1593\" data-col-size=\"sm\"><strong data-start=\"1556\" data-end=\"1591\">Live-Patching und Ger\u00e4teanschl\u00fcsse<\/strong><\/td>\n<\/tr>\n<tr data-start=\"1594\" data-end=\"1632\">\n<td data-start=\"1594\" data-end=\"1602\" data-col-size=\"sm\">3,0 mm<\/td>\n<td data-start=\"1602\" data-end=\"1632\" data-col-size=\"sm\">Links f\u00fcr den Au\u00dfenbereich und f\u00fcr hohe Beanspruchung<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1634\" data-end=\"1637\" \/>\n<h3 data-start=\"1639\" data-end=\"1687\">Optisches Verhalten, das PON-Netze erfordern<\/h3>\n<p data-start=\"1689\" data-end=\"1766\">APC-Polieren verbessert die Reflexionsleistung im Vergleich zu UPC erheblich.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1768\" data-end=\"2050\">\n<thead data-start=\"1768\" data-end=\"1810\">\n<tr data-start=\"1768\" data-end=\"1810\">\n<th class=\"\" data-start=\"1768\" data-end=\"1793\" data-col-size=\"sm\">Optisches Merkmal<\/th>\n<th class=\"\" data-start=\"1793\" data-end=\"1810\" data-col-size=\"sm\">Typisches Niveau<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1853\" data-end=\"2050\">\n<tr data-start=\"1853\" data-end=\"1885\">\n<td data-start=\"1853\" data-end=\"1861\" data-col-size=\"sm\">Faser<\/td>\n<td data-start=\"1861\" data-end=\"1885\" data-col-size=\"sm\">Einzelmode 9\/125 \u00b5m<\/td>\n<\/tr>\n<tr data-start=\"1886\" data-end=\"1916\">\n<td data-start=\"1886\" data-end=\"1897\" data-col-size=\"sm\">Endfl\u00e4che<\/td>\n<td data-start=\"1897\" data-end=\"1916\" data-col-size=\"sm\">APC (8\u00b0 abgewinkelt)<\/td>\n<\/tr>\n<tr data-start=\"1917\" data-end=\"1947\">\n<td data-start=\"1917\" data-end=\"1934\" data-col-size=\"sm\">Einf\u00fcgungsd\u00e4mpfung<\/td>\n<td data-start=\"1934\" data-end=\"1947\" data-col-size=\"sm\">\u2264 0,30 dB<\/td>\n<\/tr>\n<tr data-start=\"1948\" data-end=\"1973\">\n<td data-start=\"1948\" data-end=\"1962\" data-col-size=\"sm\">R\u00fcckflussd\u00e4mpfung<\/td>\n<td data-start=\"1962\" data-end=\"1973\" data-col-size=\"sm\">\u2265 60 dB<\/td>\n<\/tr>\n<tr data-start=\"1974\" data-end=\"2023\">\n<td data-start=\"1974\" data-end=\"1998\" data-col-size=\"sm\">Betriebswellenl\u00e4ngen<\/td>\n<td data-start=\"1998\" data-end=\"2023\" data-col-size=\"sm\">1310 \/ 1490 \/ 1550 nm<\/td>\n<\/tr>\n<tr data-start=\"2024\" data-end=\"2050\">\n<td data-start=\"2024\" data-end=\"2040\" data-col-size=\"sm\">Paarungszyklen<\/td>\n<td data-start=\"2040\" data-end=\"2050\" data-col-size=\"sm\">\u2265 1000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2052\" data-end=\"2154\">Dieses Rendite-Verlust-Niveau ist entscheidend f\u00fcr <strong data-start=\"2091\" data-end=\"2153\">GPON, XG-PON, CATV-Overlay und Langstrecken-Single-Mode-Verbindungen<\/strong>.<\/p>\n<hr data-start=\"2156\" data-end=\"2159\" \/>\n<h3 data-start=\"2161\" data-end=\"2200\">Konzipiert f\u00fcr dichte Telekommunikationsrahmen<\/h3>\n<p data-start=\"2202\" data-end=\"2354\">Auch mit APC-Geometrie verwendet der Verbinder immer noch die <strong data-start=\"2255\" data-end=\"2276\">kompaktes LC-Format<\/strong>, und erm\u00f6glicht <strong data-start=\"2287\" data-end=\"2313\">die doppelte Portdichte<\/strong> von SC-Steckverbindern auf demselben Rack-Platz.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2356\" data-end=\"2672\">\n<thead data-start=\"2356\" data-end=\"2394\">\n<tr data-start=\"2356\" data-end=\"2394\">\n<th class=\"\" data-start=\"2356\" data-end=\"2378\" data-col-size=\"sm\">Detail der Konstruktion<\/th>\n<th class=\"\" data-start=\"2378\" data-end=\"2394\" data-col-size=\"sm\">Was es bewirkt<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2432\" data-end=\"2672\">\n<tr data-start=\"2432\" data-end=\"2492\">\n<td data-start=\"2432\" data-end=\"2450\" data-col-size=\"sm\">LC-Duplex-Verriegelung<\/td>\n<td data-start=\"2450\" data-end=\"2492\" data-col-size=\"sm\">Sichert beide Fasern in der richtigen Ausrichtung<\/td>\n<\/tr>\n<tr data-start=\"2493\" data-end=\"2550\">\n<td data-start=\"2493\" data-end=\"2519\" data-col-size=\"sm\">1,25 mm Keramikh\u00fclsen<\/td>\n<td data-start=\"2519\" data-end=\"2550\" data-col-size=\"sm\">APC-Winkelgenauigkeit beibehalten<\/td>\n<\/tr>\n<tr data-start=\"2551\" data-end=\"2607\">\n<td data-start=\"2551\" data-end=\"2576\" data-col-size=\"sm\">Verst\u00e4rkte 2,0-mm-Stiefel<\/td>\n<td data-start=\"2576\" data-end=\"2607\" data-col-size=\"sm\">Verhindern Sie das Mikrobiegen von Fasern<\/td>\n<\/tr>\n<tr data-start=\"2608\" data-end=\"2672\">\n<td data-start=\"2608\" data-end=\"2634\" data-col-size=\"sm\">APC-Pr\u00e4zisionspolieren<\/td>\n<td data-start=\"2634\" data-end=\"2672\" data-col-size=\"sm\">H\u00e4lt Reflexionen vom Laser fern<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"2674\" data-end=\"2677\" \/>\n<h3 data-start=\"2679\" data-end=\"2701\">Fachliche Fragen und Antworten<\/h3>\n<p data-start=\"2703\" data-end=\"2871\"><strong data-start=\"2703\" data-end=\"2743\">Kann LC APC duplex mit LC UPC verbunden werden?<\/strong><br data-start=\"2743\" data-end=\"2746\" \/>Nein. APC- und UPC-Stecker d\u00fcrfen niemals zusammengesteckt werden. Die abgewinkelte APC-Stirnfl\u00e4che wird besch\u00e4digt und die Reflexion wird stark zunehmen.<\/p>\n<p data-start=\"2873\" data-end=\"3012\"><strong data-start=\"2873\" data-end=\"2905\">Ist Duplex f\u00fcr PON notwendig?<\/strong><br data-start=\"2905\" data-end=\"2908\" \/>Ja. OLT- und ONU-Ports erfordern <strong data-start=\"2939\" data-end=\"2963\">bidirektionale \u00dcbertragung<\/strong>, und Duplex-LC sorgt daf\u00fcr, dass Tx und Rx korrekt gepaart sind.<\/p>\n<p data-start=\"3014\" data-end=\"3227\"><strong data-start=\"3014\" data-end=\"3056\">Warum nicht 3,0 mm f\u00fcr PON-Patchkabel verwenden?<\/strong><br data-start=\"3056\" data-end=\"3059\" \/>3,0 mm wird verwendet, wenn die Kabel starken Zugkr\u00e4ften ausgesetzt sind. F\u00fcr <strong data-start=\"3119\" data-end=\"3159\">Racks, OLT-Regale und Innenrahmen<\/strong>, 2,0 mm bietet die beste Balance zwischen <strong data-start=\"3196\" data-end=\"3226\">Flexibilit\u00e4t und Schutz<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"99\" data-end=\"420\">In PON- und Langstrecken-Single-Mode-Netzen ist der gr\u00f6\u00dfte verborgene Feind nicht der Verlust - es ist <strong data-start=\"191\" data-end=\"205\">Reflexion<\/strong>.<br data-start=\"206\" data-end=\"209\" \/>Jedes reflektierte Signal erzeugt Rauschen, das die vorgelagerten Laser st\u00f6rt, insbesondere bei <strong data-start=\"298\" data-end=\"340\">GPON, XG-PON und RF-\u00fcber-Glasfaser-Systeme<\/strong>.<br data-start=\"341\" data-end=\"344\" \/>Das ist genau der Grund, warum die <strong data-start=\"368\" data-end=\"412\">LC APC 2.0mm Duplex Singlemode Stecker<\/strong> existiert.<\/p>\n<p data-start=\"422\" data-end=\"724\">Durch die Verwendung eines <strong data-start=\"434\" data-end=\"476\">8 Grad abgewinkelter K\u00f6rperkontakt (APC)<\/strong> auf beiden LC-Ferrulen, dr\u00fcckt dieser Duplex-Stecker das reflektierte Licht aus dem Faserkern heraus, anstatt es zum Sender zur\u00fcckzuschicken. Das Ergebnis ist ein <strong data-start=\"628\" data-end=\"660\">viel sauberer optischer Kanal<\/strong>, selbst wenn mehrere Splitter und lange Glasfaserleitungen beteiligt sind.<\/p>","protected":false},"featured_media":874,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[49],"product_tag":[],"class_list":{"0":"post-873","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-lc-duplex-connectors-single-modemultimode","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product\/873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/comments?post=873"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media\/874"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media?parent=873"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_brand?post=873"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_cat?post=873"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_tag?post=873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}