{"id":885,"date":"2026-02-04T03:00:39","date_gmt":"2026-02-04T03:00:39","guid":{"rendered":"https:\/\/www.fenxifiber.com\/?post_type=product&#038;p=885"},"modified":"2026-02-05T02:36:30","modified_gmt":"2026-02-05T02:36:30","slug":"lc-upc-3-0mm-duplex-singlemode","status":"publish","type":"product","link":"https:\/\/www.fenxifiber.com\/de\/product\/lc-upc-3-0mm-duplex-singlemode\/","title":{"rendered":"LC UPC 3.0mm Duplex Singlemode Glasfaserstecker"},"content":{"rendered":"<h3 data-start=\"737\" data-end=\"786\">3,0 mm Duplex - f\u00fcr reale Verkabelungswege gebaut<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"788\" data-end=\"982\">\n<thead data-start=\"788\" data-end=\"827\">\n<tr data-start=\"788\" data-end=\"827\">\n<th class=\"\" data-start=\"788\" data-end=\"801\" data-col-size=\"sm\">Typ des Kabels<\/th>\n<th class=\"\" data-start=\"801\" data-end=\"827\" data-col-size=\"md\">Wo es am besten funktioniert<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"867\" data-end=\"982\">\n<tr data-start=\"867\" data-end=\"908\">\n<td data-start=\"867\" data-end=\"875\" data-col-size=\"sm\">2,0 mm<\/td>\n<td data-start=\"875\" data-end=\"908\" data-col-size=\"md\">Kurze Jumper an Ger\u00e4teanschl\u00fcssen<\/td>\n<\/tr>\n<tr data-start=\"909\" data-end=\"982\">\n<td data-start=\"909\" data-end=\"921\" data-col-size=\"sm\"><strong data-start=\"911\" data-end=\"920\">3,0 mm<\/strong><\/td>\n<td data-start=\"921\" data-end=\"982\" data-col-size=\"md\"><strong data-start=\"923\" data-end=\"980\">Geb\u00e4ude-Backbones, Etage-zu-Etage-Verbindungen, ODF-Routing<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"984\" data-end=\"1094\">Die dickere Ummantelung absorbiert Zugkr\u00e4fte und reduziert die Mikrobiegung, wenn die Fasern \u00fcber lange Strecken verlegt werden.<\/p>\n<hr data-start=\"1096\" data-end=\"1099\" \/>\n<h3 data-start=\"1101\" data-end=\"1143\">Optische \u00dcbertragungseigenschaften<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1145\" data-end=\"1396\">\n<thead data-start=\"1145\" data-end=\"1174\">\n<tr data-start=\"1145\" data-end=\"1174\">\n<th class=\"\" data-start=\"1145\" data-end=\"1157\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"\" data-start=\"1157\" data-end=\"1174\" data-col-size=\"sm\">Typischer Wert<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1204\" data-end=\"1396\">\n<tr data-start=\"1204\" data-end=\"1236\">\n<td data-start=\"1204\" data-end=\"1212\" data-col-size=\"sm\">Faser<\/td>\n<td data-start=\"1212\" data-end=\"1236\" data-col-size=\"sm\">Einzelmode 9\/125 \u00b5m<\/td>\n<\/tr>\n<tr data-start=\"1237\" data-end=\"1258\">\n<td data-start=\"1237\" data-end=\"1251\" data-col-size=\"sm\">Polnische Art<\/td>\n<td data-start=\"1251\" data-end=\"1258\" data-col-size=\"sm\">UPC<\/td>\n<\/tr>\n<tr data-start=\"1259\" data-end=\"1289\">\n<td data-start=\"1259\" data-end=\"1276\" data-col-size=\"sm\">Einf\u00fcgungsd\u00e4mpfung<\/td>\n<td data-start=\"1276\" data-end=\"1289\" data-col-size=\"sm\">\u2264 0,30 dB<\/td>\n<\/tr>\n<tr data-start=\"1290\" data-end=\"1315\">\n<td data-start=\"1290\" data-end=\"1304\" data-col-size=\"sm\">R\u00fcckflussd\u00e4mpfung<\/td>\n<td data-start=\"1304\" data-end=\"1315\" data-col-size=\"sm\">\u2265 50 dB<\/td>\n<\/tr>\n<tr data-start=\"1316\" data-end=\"1358\">\n<td data-start=\"1316\" data-end=\"1340\" data-col-size=\"sm\">Betriebswellenl\u00e4ngen<\/td>\n<td data-start=\"1340\" data-end=\"1358\" data-col-size=\"sm\">1310 \/ 1550 nm<\/td>\n<\/tr>\n<tr data-start=\"1359\" data-end=\"1396\">\n<td data-start=\"1359\" data-end=\"1379\" data-col-size=\"sm\">Haltbarkeit der Verbindung<\/td>\n<td data-start=\"1379\" data-end=\"1396\" data-col-size=\"sm\">\u2265 1000 Zyklen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1398\" data-end=\"1496\">Diese Werte unterst\u00fctzen <strong data-start=\"1419\" data-end=\"1463\">Ethernet, SDH, Metro- und Zugangsnetze<\/strong> mit langfristiger Signalstabilit\u00e4t.<\/p>\n<hr data-start=\"1498\" data-end=\"1501\" \/>\n<h3 data-start=\"1503\" data-end=\"1528\">Duplex-LC-Struktur<\/h3>\n<p data-start=\"1530\" data-end=\"1659\">Zwei Fasern sind in einem LC-Duplex-Geh\u00e4use fixiert, so dass <strong data-start=\"1590\" data-end=\"1619\">korrekte Tx\/Rx-Ausrichtung<\/strong> auch wenn Kabel verlegt oder gewartet werden.<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1661\" data-end=\"1899\">\n<thead data-start=\"1661\" data-end=\"1687\">\n<tr data-start=\"1661\" data-end=\"1687\">\n<th class=\"\" data-start=\"1661\" data-end=\"1676\" data-col-size=\"sm\">Bauwesen<\/th>\n<th class=\"\" data-start=\"1676\" data-end=\"1687\" data-col-size=\"sm\">Nutzen Sie<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1713\" data-end=\"1899\">\n<tr data-start=\"1713\" data-end=\"1765\">\n<td data-start=\"1713\" data-end=\"1739\" data-col-size=\"sm\">1,25 mm Keramikh\u00fclsen<\/td>\n<td data-col-size=\"sm\" data-start=\"1739\" data-end=\"1765\">Pr\u00e4zise Kernausrichtung<\/td>\n<\/tr>\n<tr data-start=\"1766\" data-end=\"1809\">\n<td data-start=\"1766\" data-end=\"1791\" data-col-size=\"sm\">UPC polierte Endfl\u00e4chen<\/td>\n<td data-col-size=\"sm\" data-start=\"1791\" data-end=\"1809\">Geringe Reflexion<\/td>\n<\/tr>\n<tr data-start=\"1810\" data-end=\"1849\">\n<td data-start=\"1810\" data-end=\"1827\" data-col-size=\"sm\">Duplex LC-Klemme<\/td>\n<td data-col-size=\"sm\" data-start=\"1827\" data-end=\"1849\">Beh\u00e4lt die Polarit\u00e4t bei<\/td>\n<\/tr>\n<tr data-start=\"1850\" data-end=\"1899\">\n<td data-start=\"1850\" data-end=\"1871\" data-col-size=\"sm\">3,0 mm dicker Mantel<\/td>\n<td data-start=\"1871\" data-end=\"1899\" data-col-size=\"sm\">Sch\u00fctzt vor Verspannungen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1901\" data-end=\"1904\" \/>\n<h3 data-start=\"1906\" data-end=\"1928\">Fachliche Fragen und Antworten<\/h3>\n<p data-start=\"1930\" data-end=\"2085\"><strong data-start=\"1930\" data-end=\"1978\">Wann sollte ich 3,0 mm anstelle von 2,0 mm w\u00e4hlen?<\/strong><br data-start=\"1978\" data-end=\"1981\" \/>Wenn der Jumper durch <strong data-start=\"2010\" data-end=\"2053\">Kabelkan\u00e4le, Steigleitungen oder Backbone-Rahmen<\/strong> wo es verbogen oder gezogen werden kann.<\/p>\n<p data-start=\"2087\" data-end=\"2216\"><strong data-start=\"2087\" data-end=\"2135\">Ist dies mit allen LC UPC Adaptern kompatibel?<\/strong><br data-start=\"2135\" data-end=\"2138\" \/>Ja, die LC-Schnittstelle ist Standard und passt zu allen LC UPC Panels und Transceivern.<\/p>\n<p data-start=\"2218\" data-end=\"2353\"><strong data-start=\"2218\" data-end=\"2255\">Kann dies auch f\u00fcr PON-Systeme verwendet werden?<\/strong><br data-start=\"2255\" data-end=\"2258\" \/>Ja, aber f\u00fcr RF-Overlay oder reflexionsempfindliche PON-Systeme, <strong data-start=\"2319\" data-end=\"2329\">LC APC<\/strong> wird stattdessen empfohlen.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"164\" data-end=\"520\">Die <strong data-start=\"168\" data-end=\"224\">LC UPC 3.0mm Duplex Singlemode Glasfaserstecker<\/strong> ist konzipiert f\u00fcr <strong data-start=\"241\" data-end=\"288\">Faserverbindungen, die \u00fcber Jahre hinweg stabil bleiben m\u00fcssen<\/strong>, nicht nur innerhalb eines Regals, sondern in allen <strong data-start=\"324\" data-end=\"365\">Etagen, Korridore und Backbone-Rahmen<\/strong>.<br data-start=\"366\" data-end=\"369\" \/>Wo Verbindungskabel durchgef\u00fchrt werden <strong data-start=\"406\" data-end=\"463\">Kabelrinnen, vertikale Sch\u00e4chte oder Verteilerschr\u00e4nke<\/strong>, wird eine dickere und sch\u00fctzende Jacke unerl\u00e4sslich.<\/p>\n<p data-start=\"522\" data-end=\"730\">Dieser 3,0-mm-Duplex-LC-Stecker kombiniert <strong data-start=\"562\" data-end=\"588\">verlustarmes UPC-Polieren<\/strong> mit einer <strong data-start=\"596\" data-end=\"626\">verst\u00e4rkte Kabelstruktur<\/strong>, und schafft eine zuverl\u00e4ssige Verbindung zwischen <strong data-start=\"667\" data-end=\"729\">optische Verteilerk\u00e4sten, Schalter und Zugangsger\u00e4te<\/strong>.<\/p>","protected":false},"featured_media":886,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[49],"product_tag":[],"class_list":{"0":"post-885","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-lc-duplex-connectors-single-modemultimode","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product\/885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/comments?post=885"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media\/886"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/media?parent=885"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_brand?post=885"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_cat?post=885"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/de\/wp-json\/wp\/v2\/product_tag?post=885"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}