Descripción
Designed for Stability in Demanding Installations
Both FC and ST connectors are known for their positive locking mechanisms. The FC end uses a threaded coupling to prevent micro-movement, while the ST end locks with a twist-and-click bayonet, making the cable resistant to vibration and accidental disconnects.
Con Pulido UPC on both ends, fiber cores make smooth physical contact, keeping insertion loss low and return loss stable, which is especially important for test and monitoring systems.
Technical Profile
| Parámetro | FC/UPC–ST/UPC-50/125-DX |
|---|---|
| Tipo de fibra | Multimodo 50/125 μm |
| Modo Fibra | Compatible con OM2 / OM3 |
| Configuración | Dúplex (DX) |
| Conector A | FC / UPC |
| Conector B | ST / UPC |
| Longitud de onda operativa | 850 nm / 1300 nm |
| Pérdida de inserción | ≤ 0,30 dB |
| Pérdida de retorno | ≥ 30 dB |
| Cubierta del cable | LSZH o PVC |
| Resistencia a la tracción | ≥ 200 N |
| Durabilidad | ≥ 1000 ciclos de apareamiento |
| Temperatura de funcionamiento | De -10 °C a +70 °C |
| Normas | IEC, TIA-568, RoHS, REACH |
Real-World Performance
Uso Fibra multimodo de 50/125 µm at 850 nm, this cable supports:
-
Ethernet 10G hasta 300 m (OM3)
-
40G and 100G multimode links up to 100–150 m
This makes it suitable for:
-
Industrial Ethernet networks
-
Red troncal del campus y del edificio
-
Fiber test equipment
-
Optical distribution frames
-
Security and monitoring systems
Built for Long-Term Reliability
Each patch cord is assembled with casquillos cerámicos de alta precisión and inspected using automated interferometry and insertion-loss testing. This ensures consistent optical alignment y repeatable performance over thousands of connection cycles, even in high-traffic patching environments.
En Opción de cubierta LSZH further supports installations in data centers and public buildings where fire safety and low smoke emission son necesarios.
Preguntas y respuestas profesionales
Q1: What makes FC and ST connectors good for industrial use?
Both use locking mechanisms that resist vibration and accidental unplugging, making them ideal for harsh or active environments.
Q2: Is this cable suitable for 10G Ethernet?
Sí. Con fibra OM3 de 50/125, es compatible con 10G links up to 300 meters at 850 nm.
Q3: Can this cable be used with test instruments?
Absolutely. FC connectors are common on OTDRs and optical power meters, while ST is widely used on distribution frames.
Q4: Does UPC polishing affect signal quality?
Yes. UPC provides low insertion loss and stable return loss (≥30 dB), which improves measurement accuracy and transmission reliability.