{"id":1240,"date":"2026-10-15T04:19:00","date_gmt":"2026-10-15T04:19:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-package-types\/"},"modified":"2026-10-02T09:59:33","modified_gmt":"2026-10-02T09:59:33","slug":"plc-splitter-package-types","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/es\/plc-splitter-package-types\/","title":{"rendered":"Tipos de paquetes de divisores PLC: Bare, Mini, ABS, LGX y Rack"},"content":{"rendered":"<p><strong>Choose the PLC splitter package after the cabinet, closure or rack interface is fixed. The optical circuit may be similar across formats, but tube diameter, pigtail exit, connector presentation, mounting method and technician access determine whether the assembly can be installed and serviced.<\/strong><\/p>\n<p>Bare-fibre and steel-tube units suit protected internal integration; ABS modules add mechanical protection; LGX, cassette and rack formats provide connectorized presentation and mounting features. Package names are not universal dimensional standards, so procurement should request a controlled outline drawing and test a production-representative sample in the target enclosure.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats for enclosure and rack selection\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter package types?<\/h2>\n<p>Utiliza la tabla de decisiones para convertir el tema en datos controlados de compra, dise\u00f1o y aceptaci\u00f3n. Cada fila debe verificarse con respecto a las especificaciones reales del equipo, la ruta y el destino, en lugar de copiarse de un cat\u00e1logo gen\u00e9rico.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u00c1rea de decisi\u00f3n<\/th>\n<th>Qu\u00e9 hay que especificar<\/th>\n<th>Por qu\u00e9 es importante<\/th>\n<th>Pruebas que deben conservarse<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Installation location<\/td>\n<td>Closure, wall box, cabinet or rack<\/td>\n<td>Defines protection and mounting needs<\/td>\n<td>Approved enclosure drawing<\/td>\n<\/tr>\n<tr>\n<td>Fibre presentation<\/td>\n<td>Bare fibre, pigtails or adapters<\/td>\n<td>Changes splicing and patching work<\/td>\n<td>Port and tail schedule<\/td>\n<\/tr>\n<tr>\n<td>Mechanical envelope<\/td>\n<td>Body, bend exits and mounting points<\/td>\n<td>Controls fit and routing<\/td>\n<td>Dimensioned outline<\/td>\n<\/tr>\n<tr>\n<td>Service access<\/td>\n<td>Cleaning, replacement and labels<\/td>\n<td>Affects restoration time<\/td>\n<td>Populated enclosure trial<\/td>\n<\/tr>\n<tr>\n<td>Optical evidence<\/td>\n<td>Port-level loss and uniformity<\/td>\n<td>Links package to tested device<\/td>\n<td>Serialized test report<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter package types in the Project<\/h2>\n<p>Los controles que se muestran a continuaci\u00f3n vinculan el plano, la muestra, el lote de producci\u00f3n y el resultado de la instalaci\u00f3n. Se han dise\u00f1ado deliberadamente para ser pr\u00e1cticos: cada uno genera un registro que los equipos de compras, ingenier\u00eda y de campo pueden revisar posteriormente.<\/p>\n<h3>Design from the enclosure inward<\/h3>\n<p>Reserve space for the package, tails, connectors, splice protectors and minimum routing radius. A module that fits an empty box may still block the cover or adjacent adapters after cabling.<\/p>\n<h3>Separate optical and mechanical requirements<\/h3>\n<p>State the split configuration and optical acceptance separately from package dimensions, cable lengths, connector types and mounting hardware. This prevents a correct optical device from arriving in the wrong mechanical format.<\/p>\n<h3>Approve the installed sample<\/h3>\n<p>Load one representative enclosure with the intended splitter, adapters and pigtails. Verify identification, cleaning access, tail routing and replacement sequence before volume release.<\/p>\n<h3>Control package substitutions<\/h3>\n<p>Require notification when the housing, exit boot, cable or connector supplier changes. Recheck fit and optical records against the approved drawing and sample.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave circuit splitter chip before packaging\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>Verificaciones de aceptaci\u00f3n y entrega<\/h2>\n<p>Acuerden el m\u00e9todo y el procedimiento antes de que comience la prueba. Un resultado sin un responsable definido del registro o sin una acci\u00f3n en caso de falla resulta dif\u00edcil de utilizar durante la autorizaci\u00f3n de env\u00edo o la puesta en servicio.<\/p>\n<table>\n<thead>\n<tr>\n<th>Verificar<\/th>\n<th>M\u00e9todo<\/th>\n<th>R\u00e9cord<\/th>\n<th>Acci\u00f3n en caso de falla<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Outline fit<\/td>\n<td>Install in target enclosure<\/td>\n<td>Fit photos and dimensions<\/td>\n<td>Revise package or enclosure<\/td>\n<\/tr>\n<tr>\n<td>Tail routing<\/td>\n<td>Route every output<\/td>\n<td>Routing record<\/td>\n<td>Correct length or exit<\/td>\n<\/tr>\n<tr>\n<td>Port identity<\/td>\n<td>Trace input and outputs<\/td>\n<td>Label and continuity map<\/td>\n<td>Relabel before shipment<\/td>\n<\/tr>\n<tr>\n<td>Prueba \u00f3ptica<\/td>\n<td>Measure each required port<\/td>\n<td>Serialized report<\/td>\n<td>Quarantine failing unit<\/td>\n<\/tr>\n<tr>\n<td>Service trial<\/td>\n<td>Clean and replace sample<\/td>\n<td>Technician sign-off<\/td>\n<td>Improve access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter used in an FTTH distribution point\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>Normas y pruebas que respaldan la orden de compra<\/h2>\n<p>Corning enumera los formatos de componentes, m\u00f3dulos y bastidores, e indica que su gama de divisores PLC cumple con la certificaci\u00f3n GR-1209\/1221. V\u00e9ase <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">Referencia de calificaci\u00f3n del divisor de Corning PLC<\/a>.<\/p>\n<p>El documento de 2025 describe las normas de referencia para GPON, XG(S)-PON, 50G-PON y la coexistencia en redes de acceso. V\u00e9ase <a href=\"https:\/\/www.itu.int\/epublications\/en\/publication\/itu-t-gstp-bain-2025-03-broadband-access-and-in-premises-networks\" target=\"_blank\" rel=\"noopener\">Documento t\u00e9cnico de la UIT sobre el acceso de banda ancha<\/a>.<\/p>\n<p>La recomendaci\u00f3n vigente de 2024 define las categor\u00edas de fibra monomodo insensibles a la flexi\u00f3n y su \u00e1mbito de aplicaci\u00f3n. V\u00e9ase <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.657-202408-I\" target=\"_blank\" rel=\"noopener\">Recomendaci\u00f3n UIT-T G.657 sobre fibra insensible a la flexi\u00f3n<\/a>.<\/p>\n<h2>RFQ checklist<\/h2>\n<p>Package selection is an enclosure-engineering decision as well as an optical purchase. Freeze the outline, fibre presentation, label scheme and port-level test record in the same approval package.<\/p>\n<ul>\n<li>Name the target enclosure<\/li>\n<li>Request a controlled outline drawing<\/li>\n<li>Specify tail and connector presentation<\/li>\n<li>Approve a populated sample<\/li>\n<li>Link each serial number to optical results<\/li>\n<\/ul>\n<p>Para obtener una cotizaci\u00f3n espec\u00edfica para tu proyecto, consulta la p\u00e1gina de Fenxi <a href=\"https:\/\/www.fenxifiber.com\/es\/product-category\/divisor-de-fibra-optica\/\" target=\"_blank\" rel=\"noopener\">Gama de divisores de fibra \u00f3ptica<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/es\/product\/divisor-de-fibra-optica-sc-apc-116-divisor-de-fibra-plc-de-baja-perdida\/\" target=\"_blank\" rel=\"noopener\">Divisor 1\u00d716 SC APC PLC<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/es\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">Comparaci\u00f3n entre el PLC y el divisor FBT<\/a>, y <a href=\"https:\/\/www.fenxifiber.com\/es\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">Gu\u00eda para la planificaci\u00f3n del presupuesto de potencia en redes PON<\/a>. Env\u00eda el mercado de destino, las interfaces de conexi\u00f3n, el tipo de fibra, la estructura del cable, las cantidades, la revisi\u00f3n del plano y los registros de pruebas requeridos. De esta manera, la respuesta podr\u00e1 distinguir entre las opciones est\u00e1ndar del cat\u00e1logo y los art\u00edculos que requieran confirmaci\u00f3n o herramientas personalizadas.<\/p>","protected":false},"excerpt":{"rendered":"<p>Compara los paquetes de divisores PLC sin carcasa, de tubo de acero, ABS, LGX, tipo casete y para rack seg\u00fan el ajuste a la carcasa, el acceso a los conectores, el tendido de cables, la protecci\u00f3n, las pruebas y el etiquetado.<\/p>","protected":false},"author":1,"featured_media":1131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/posts\/1240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/comments?post=1240"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/posts\/1240\/revisions"}],"predecessor-version":[{"id":1241,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/posts\/1240\/revisions\/1241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media\/1131"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media?parent=1240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/categories?post=1240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/tags?post=1240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}