{"id":562,"date":"2026-02-03T01:58:45","date_gmt":"2026-02-03T01:58:45","guid":{"rendered":"https:\/\/www.fenxifiber.com\/?post_type=product&#038;p=562"},"modified":"2026-02-04T01:11:53","modified_gmt":"2026-02-04T01:11:53","slug":"mpo-lc-sm-0-9-mm-12-nucleos","status":"publish","type":"product","link":"https:\/\/www.fenxifiber.com\/es\/product\/mpo-lc-sm-0-9mm-12core\/","title":{"rendered":"MPO-LC-SM-0,9mm-12Core Cable de fibra monomodo Breakout"},"content":{"rendered":"<h3 data-start=\"736\" data-end=\"773\"><strong data-start=\"740\" data-end=\"773\">\u00bfQu\u00e9 hace que este cable sea especial?<\/strong><\/h3>\n<p data-start=\"775\" data-end=\"892\">A diferencia de los cables multitipo est\u00e1ndar, este modelo est\u00e1 dise\u00f1ado para <strong data-start=\"845\" data-end=\"891\">transmisi\u00f3n de larga distancia y alta precisi\u00f3n<\/strong>:<\/p>\n<ul data-start=\"894\" data-end=\"1469\">\n<li data-start=\"894\" data-end=\"1056\">\n<p data-start=\"896\" data-end=\"1056\"><strong data-start=\"896\" data-end=\"928\">Verdadero rendimiento monomodo<\/strong><br data-start=\"928\" data-end=\"931\" \/>Admite longitudes de onda de <strong data-start=\"957\" data-end=\"980\">1310 nm y 1550 nm<\/strong>, lo que permite conexiones de largo alcance entre salas de datos, campus y redes metropolitanas.<\/p>\n<\/li>\n<li data-start=\"1058\" data-end=\"1225\">\n<p data-start=\"1060\" data-end=\"1225\"><strong data-start=\"1060\" data-end=\"1097\">Fibras ultrafinas de 0,9 mm<\/strong><br data-start=\"1097\" data-end=\"1100\" \/>Cada tramo LC tiene un di\u00e1metro de solo 0,9 mm, lo que permite un tendido de cables m\u00e1s limpio y mejora considerablemente el flujo de aire dentro de los bastidores densos.<\/p>\n<\/li>\n<li data-start=\"1227\" data-end=\"1341\">\n<p data-start=\"1229\" data-end=\"1341\"><strong data-start=\"1229\" data-end=\"1262\">Perfecto para \u00f3ptica de alta velocidad<\/strong><br data-start=\"1262\" data-end=\"1265\" \/>Funciona con <strong data-start=\"1278\" data-end=\"1327\">QSFP-DD, OSFP, CFP2 y 400G\/800G PSM4 y DR4<\/strong> transceptores.<\/p>\n<\/li>\n<li data-start=\"1343\" data-end=\"1469\">\n<p data-start=\"1345\" data-end=\"1469\"><strong data-start=\"1345\" data-end=\"1379\">MPO de baja p\u00e9rdida y pulido de f\u00e1brica<\/strong><br data-start=\"1379\" data-end=\"1382\" \/>Dise\u00f1ado para cumplir con los estrictos requisitos de p\u00e9rdida de inserci\u00f3n que exigen los sistemas \u00f3pticos monomodo modernos.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1471\" data-end=\"1474\" \/>\n<h3 data-start=\"1476\" data-end=\"1509\"><strong data-start=\"1480\" data-end=\"1509\">Datos \u00f3pticos y mec\u00e1nicos<\/strong><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1511\" data-end=\"1937\">\n<thead data-start=\"1511\" data-end=\"1535\">\n<tr data-start=\"1511\" data-end=\"1535\">\n<th class=\"\" data-start=\"1511\" data-end=\"1518\" data-col-size=\"sm\">Art\u00edculo<\/th>\n<th class=\"\" data-start=\"1518\" data-end=\"1535\" data-col-size=\"sm\">Especificaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1562\" data-end=\"1937\">\n<tr data-start=\"1562\" data-end=\"1605\">\n<td data-start=\"1562\" data-end=\"1575\" data-col-size=\"sm\">Tipo de fibra<\/td>\n<td data-start=\"1575\" data-end=\"1605\" data-col-size=\"sm\">OS2 monomodo (9\/125 \u00b5m)<\/td>\n<\/tr>\n<tr data-start=\"1606\" data-end=\"1626\">\n<td data-start=\"1606\" data-end=\"1620\" data-col-size=\"sm\">Recuento de fibras<\/td>\n<td data-start=\"1620\" data-end=\"1626\" data-col-size=\"sm\">12<\/td>\n<\/tr>\n<tr data-start=\"1627\" data-end=\"1666\">\n<td data-start=\"1627\" data-end=\"1643\" data-col-size=\"sm\">Conector MPO<\/td>\n<td data-start=\"1643\" data-end=\"1666\" data-col-size=\"sm\">MPO\/MTP, 12 fibras<\/td>\n<\/tr>\n<tr data-start=\"1667\" data-end=\"1694\">\n<td data-start=\"1667\" data-end=\"1683\" data-col-size=\"sm\">Conectores LC<\/td>\n<td data-start=\"1683\" data-end=\"1694\" data-col-size=\"sm\">12 \u00d7 LC<\/td>\n<\/tr>\n<tr data-start=\"1695\" data-end=\"1731\">\n<td data-start=\"1695\" data-end=\"1721\" data-col-size=\"sm\">Di\u00e1metro de la fibra de ruptura<\/td>\n<td data-start=\"1721\" data-end=\"1731\" data-col-size=\"sm\">0,9 mm<\/td>\n<\/tr>\n<tr data-start=\"1732\" data-end=\"1777\">\n<td data-start=\"1732\" data-end=\"1756\" data-col-size=\"sm\">Longitudes de onda operativas<\/td>\n<td data-col-size=\"sm\" data-start=\"1756\" data-end=\"1777\">1310 nm \/ 1550 nm<\/td>\n<\/tr>\n<tr data-start=\"1778\" data-end=\"1826\">\n<td data-start=\"1778\" data-end=\"1795\" data-col-size=\"sm\">P\u00e9rdida de inserci\u00f3n<\/td>\n<td data-col-size=\"sm\" data-start=\"1795\" data-end=\"1826\">MPO \u2264 0,35 dB, LC \u2264 0,30 dB<\/td>\n<\/tr>\n<tr data-start=\"1827\" data-end=\"1873\">\n<td data-start=\"1827\" data-end=\"1841\" data-col-size=\"sm\">P\u00e9rdida de retorno<\/td>\n<td data-col-size=\"sm\" data-start=\"1841\" data-end=\"1873\">\u2265 50 dB (opciones LC UPC\/APC)<\/td>\n<\/tr>\n<tr data-start=\"1874\" data-end=\"1898\">\n<td data-start=\"1874\" data-end=\"1883\" data-col-size=\"sm\">Chamarra<\/td>\n<td data-start=\"1883\" data-end=\"1898\" data-col-size=\"sm\">LSZH o PVC<\/td>\n<\/tr>\n<tr data-start=\"1899\" data-end=\"1937\">\n<td data-start=\"1899\" data-end=\"1917\" data-col-size=\"sm\">Temperatura de funcionamiento.<\/td>\n<td data-col-size=\"sm\" data-start=\"1917\" data-end=\"1937\">De -10 \u00b0C a +70 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1939\" data-end=\"1942\" \/>\n<h3 data-start=\"1944\" data-end=\"1980\"><strong data-start=\"1948\" data-end=\"1980\">Escenarios t\u00edpicos de implementaci\u00f3n<\/strong><\/h3>\n<p data-start=\"1982\" data-end=\"2011\">Este cable se utiliza ampliamente en:<\/p>\n<ul data-start=\"2013\" data-end=\"2224\">\n<li data-start=\"2013\" data-end=\"2058\">\n<p data-start=\"2015\" data-end=\"2058\"><strong data-start=\"2015\" data-end=\"2056\">Interconexiones de centros de datos de 400G\/800G<\/strong><\/p>\n<\/li>\n<li data-start=\"2059\" data-end=\"2109\">\n<p data-start=\"2061\" data-end=\"2109\"><strong data-start=\"2061\" data-end=\"2107\">Arquitecturas de hoja-espina y conexi\u00f3n cruzada<\/strong><\/p>\n<\/li>\n<li data-start=\"2110\" data-end=\"2144\">\n<p data-start=\"2112\" data-end=\"2144\"><strong data-start=\"2112\" data-end=\"2142\">Redes de telecomunicaciones y metro<\/strong><\/p>\n<\/li>\n<li data-start=\"2145\" data-end=\"2185\">\n<p data-start=\"2147\" data-end=\"2185\"><strong data-start=\"2147\" data-end=\"2183\">Cl\u00fasteres de IA y nube a hiperescala<\/strong><\/p>\n<\/li>\n<li data-start=\"2186\" data-end=\"2224\">\n<p data-start=\"2188\" data-end=\"2224\"><strong data-start=\"2188\" data-end=\"2224\">Sistemas troncales MPO monomodo<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2226\" data-end=\"2229\" \/>\n<h3 data-start=\"2231\" data-end=\"2285\"><strong data-start=\"2235\" data-end=\"2285\">\u00bfPor qu\u00e9 MPO-LC-SM-0,9 mm-12 n\u00facleos es la elecci\u00f3n correcta?<\/strong><\/h3>\n<p data-start=\"2287\" data-end=\"2656\">A medida que aumentan las velocidades de datos, <strong data-start=\"2307\" data-end=\"2346\">La fibra monomodo se vuelve esencial.<\/strong>. Este cable combina el <strong data-start=\"2372\" data-end=\"2390\">densidad de MPO<\/strong> con el <strong data-start=\"2400\" data-end=\"2419\">precisi\u00f3n de LC<\/strong>, lo que le permite implementar <strong data-start=\"2444\" data-end=\"2498\">Enlaces de alto n\u00famero de fibras con un espacio y una p\u00e9rdida m\u00ednimos.<\/strong>. El dise\u00f1o de salida de 0,9 mm le ofrece una instalaci\u00f3n limpia y profesional, al tiempo que cumple con los estrictos requisitos \u00f3pticos que exigen los modernos sistemas \u00f3pticos de 400G y 800G.<\/p>\n<hr data-start=\"2658\" data-end=\"2661\" \/>\n<h2 data-start=\"2663\" data-end=\"2686\"><strong data-start=\"2666\" data-end=\"2686\">Preguntas y respuestas profesionales<\/strong><\/h2>\n<p data-start=\"2688\" data-end=\"2861\"><strong data-start=\"2688\" data-end=\"2744\">P1: \u00bfCu\u00e1l es la ventaja de las fibras de 0,9 mm?<\/strong><br data-start=\"2744\" data-end=\"2747\" \/>Permiten una densidad de puertos mucho mayor, un enrutamiento m\u00e1s sencillo y un mejor flujo de aire en comparaci\u00f3n con los cables de conexi\u00f3n est\u00e1ndar de 2,0 mm.<\/p>\n<p data-start=\"2863\" data-end=\"3017\"><strong data-start=\"2863\" data-end=\"2928\">P2: \u00bfEste cable es compatible con transceptores de 400G y 800G?<\/strong><br data-start=\"2928\" data-end=\"2931\" \/>S\u00ed. Est\u00e1 dise\u00f1ado para <strong data-start=\"2955\" data-end=\"3016\">DR4, PSM4 y m\u00f3dulos \u00f3pticos paralelos monomodo similares.<\/strong>.<\/p>\n<p data-start=\"3019\" data-end=\"3180\"><strong data-start=\"3019\" data-end=\"3074\">P3: \u00bfSe puede utilizar este cable para conexiones de larga distancia?<\/strong><br data-start=\"3074\" data-end=\"3077\" \/>S\u00ed. Como cable monomodo OS2, admite distancias de <strong data-start=\"3136\" data-end=\"3150\">kil\u00f3metros<\/strong>, mucho m\u00e1s all\u00e1 de los l\u00edmites multimodo.<\/p>\n<p data-start=\"3182\" data-end=\"3347\"><strong data-start=\"3182\" data-end=\"3222\">P4: \u00bfNecesito conectores APC o UPC?<\/strong><br data-start=\"3222\" data-end=\"3225\" \/>UPC es habitual en centros de datos, mientras que APC es la opci\u00f3n preferida para redes DWDM o redes de telecomunicaciones de largo alcance. Ambas opciones est\u00e1n disponibles.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"65\" data-end=\"475\">En <strong data-start=\"69\" data-end=\"95\">MPO-LC-SM-0.9mm-12Core<\/strong> es un producto dise\u00f1ado con precisi\u00f3n <strong data-start=\"122\" data-end=\"161\">Cable divisor MPO a LC monomodo<\/strong> Dise\u00f1ado para redes \u00f3pticas de ultra alta densidad y largo alcance. Construido con <strong data-start=\"235\" data-end=\"269\">Fibra monomodo OS2 9\/125 \u00b5m<\/strong> y un ultra delgado <strong data-start=\"288\" data-end=\"317\">Estructura de separaci\u00f3n de 0,9 mm<\/strong>, este conjunto est\u00e1 optimizado para los modernos <strong data-start=\"357\" data-end=\"381\">100G, 400G y 800G<\/strong> centros de datos e instalaciones de telecomunicaciones donde la eficiencia del espacio y la integridad de la se\u00f1al son fundamentales.<\/p>\n<p data-start=\"477\" data-end=\"729\">En lugar de doce cables de conexi\u00f3n separados, un solo <strong data-start=\"526\" data-end=\"552\">Interfaz MPO de 12 fibras<\/strong> transporta todos los canales desde una red troncal o un transceptor, y luego se distribuye en <strong data-start=\"625\" data-end=\"656\">12 conectores LC individuales<\/strong> para conexi\u00f3n directa a m\u00f3dulos \u00f3pticos, paneles de conexi\u00f3n o sistemas DWDM.<\/p>","protected":false},"featured_media":563,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[42],"product_tag":[],"class_list":["post-562","product","type-product","status-publish","has-post-thumbnail","product_cat-mpo-mtp-fiber-optic-patch-cord","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product\/562","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/comments?post=562"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media\/563"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media?parent=562"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_brand?post=562"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_cat?post=562"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_tag?post=562"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}