{"id":713,"date":"2026-02-03T07:28:23","date_gmt":"2026-02-03T07:28:23","guid":{"rendered":"https:\/\/www.fenxifiber.com\/?post_type=product&#038;p=713"},"modified":"2026-02-04T01:39:19","modified_gmt":"2026-02-04T01:39:19","slug":"fc-apc-sc-apc-blindado","status":"publish","type":"product","link":"https:\/\/www.fenxifiber.com\/es\/product\/fc-apc-sc-apc-armoured\/","title":{"rendered":"FC\/APC-SC\/APC Cable de conexi\u00f3n de fibra \u00f3ptica monomodo blindado"},"content":{"rendered":"<h3 data-start=\"740\" data-end=\"790\"><strong data-start=\"744\" data-end=\"790\">\u00bfPor qu\u00e9 pasar de FC\/APC a SC\/APC en un dise\u00f1o blindado?<\/strong><\/h3>\n<ul data-start=\"792\" data-end=\"1269\">\n<li data-start=\"792\" data-end=\"926\">\n<p data-start=\"794\" data-end=\"926\"><strong data-start=\"794\" data-end=\"804\">FC\/APC<\/strong> ofertas <strong data-start=\"812\" data-end=\"849\">rosca, bloqueo a prueba de vibraciones<\/strong>, ideal para <strong data-start=\"861\" data-end=\"923\">equipos de prueba, bastidores de telecomunicaciones y enlaces de operadores a largo plazo<\/strong>.<\/p>\n<\/li>\n<li data-start=\"927\" data-end=\"1015\">\n<p data-start=\"929\" data-end=\"1015\"><strong data-start=\"929\" data-end=\"939\">SC\/APC<\/strong> es la interfaz est\u00e1ndar para <strong data-start=\"970\" data-end=\"1012\">ODF, divisores PON y cabeceras CATV<\/strong>.<\/p>\n<\/li>\n<li data-start=\"1016\" data-end=\"1120\">\n<p data-start=\"1018\" data-end=\"1120\"><strong data-start=\"1018\" data-end=\"1046\">Pulido APC (\u00e1ngulo de 8\u00b0)<\/strong> entrega <strong data-start=\"1056\" data-end=\"1078\">p\u00e9rdida de retorno \u226560 dB<\/strong>, minimizando los reflejos y el ruido del l\u00e1ser.<\/p>\n<\/li>\n<li data-start=\"1121\" data-end=\"1269\">\n<p data-start=\"1123\" data-end=\"1269\"><strong data-start=\"1123\" data-end=\"1141\">Cable blindado<\/strong> protege contra <strong data-start=\"1159\" data-end=\"1206\">aplastamiento, tracci\u00f3n, roedores y curvas cerradas<\/strong>, lo que lo hace perfecto para <strong data-start=\"1230\" data-end=\"1268\">implementaciones al aire libre e industriales<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1271\" data-end=\"1387\">Esta combinaci\u00f3n hace que el cable sea un <strong data-start=\"1306\" data-end=\"1386\">opci\u00f3n preferida para redes FTTH, GPON, XG-PON, XGS-PON y RF sobre fibra<\/strong>.<\/p>\n<hr data-start=\"1389\" data-end=\"1392\" \/>\n<h3 data-start=\"1394\" data-end=\"1426\"><strong data-start=\"1398\" data-end=\"1426\">Especificaciones t\u00e9cnicas<\/strong><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1428\" data-end=\"1978\">\n<thead data-start=\"1428\" data-end=\"1466\">\n<tr data-start=\"1428\" data-end=\"1466\">\n<th class=\"\" data-start=\"1428\" data-end=\"1440\" data-col-size=\"sm\">Par\u00e1metro<\/th>\n<th class=\"\" data-start=\"1440\" data-end=\"1466\" data-col-size=\"sm\">FC\/APC\u2013SC\/APC Blindado<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1495\" data-end=\"1978\">\n<tr data-start=\"1495\" data-end=\"1538\">\n<td data-start=\"1495\" data-end=\"1508\" data-col-size=\"sm\">Tipo de fibra<\/td>\n<td data-start=\"1508\" data-end=\"1538\" data-col-size=\"sm\">OS2 monomodo (9\/125 \u03bcm)<\/td>\n<\/tr>\n<tr data-start=\"1539\" data-end=\"1565\">\n<td data-start=\"1539\" data-end=\"1553\" data-col-size=\"sm\">Conector A<\/td>\n<td data-start=\"1553\" data-end=\"1565\" data-col-size=\"sm\">FC \/ APC<\/td>\n<\/tr>\n<tr data-start=\"1566\" data-end=\"1592\">\n<td data-start=\"1566\" data-end=\"1580\" data-col-size=\"sm\">Conector B<\/td>\n<td data-start=\"1580\" data-end=\"1592\" data-col-size=\"sm\">SC \/ APC<\/td>\n<\/tr>\n<tr data-start=\"1593\" data-end=\"1626\">\n<td data-start=\"1593\" data-end=\"1607\" data-col-size=\"sm\">Tipo de polaco<\/td>\n<td data-start=\"1607\" data-end=\"1626\" data-col-size=\"sm\">APC (\u00e1ngulo de 8\u00b0)<\/td>\n<\/tr>\n<tr data-start=\"1627\" data-end=\"1688\">\n<td data-start=\"1627\" data-end=\"1645\" data-col-size=\"sm\">Estructura del cable<\/td>\n<td data-start=\"1645\" data-end=\"1688\" data-col-size=\"sm\">Blindaje met\u00e1lico (tubo de acero o aluminio)<\/td>\n<\/tr>\n<tr data-start=\"1689\" data-end=\"1733\">\n<td data-start=\"1689\" data-end=\"1712\" data-col-size=\"sm\">Longitud de onda operativa<\/td>\n<td data-start=\"1712\" data-end=\"1733\" data-col-size=\"sm\">1310 nm \/ 1550 nm<\/td>\n<\/tr>\n<tr data-start=\"1734\" data-end=\"1764\">\n<td data-start=\"1734\" data-end=\"1751\" data-col-size=\"sm\">P\u00e9rdida de inserci\u00f3n<\/td>\n<td data-start=\"1751\" data-end=\"1764\" data-col-size=\"sm\">\u2264 0,30 dB<\/td>\n<\/tr>\n<tr data-start=\"1765\" data-end=\"1790\">\n<td data-start=\"1765\" data-end=\"1779\" data-col-size=\"sm\">P\u00e9rdida de retorno<\/td>\n<td data-start=\"1779\" data-end=\"1790\" data-col-size=\"sm\">\u2265 60 dB<\/td>\n<\/tr>\n<tr data-start=\"1791\" data-end=\"1851\">\n<td data-start=\"1791\" data-end=\"1810\" data-col-size=\"sm\">Resistencia a la tracci\u00f3n<\/td>\n<td data-start=\"1810\" data-end=\"1851\" data-col-size=\"sm\">Mucho m\u00e1s alto que los cables de conexi\u00f3n est\u00e1ndar.<\/td>\n<\/tr>\n<tr data-start=\"1852\" data-end=\"1898\">\n<td data-start=\"1852\" data-end=\"1874\" data-col-size=\"sm\">Radio de curvatura m\u00ednimo<\/td>\n<td data-start=\"1874\" data-end=\"1898\" data-col-size=\"sm\">\u2265 10 veces el di\u00e1metro del cable<\/td>\n<\/tr>\n<tr data-start=\"1899\" data-end=\"1935\">\n<td data-start=\"1899\" data-end=\"1916\" data-col-size=\"sm\">Opciones de chamarra<\/td>\n<td data-start=\"1916\" data-end=\"1935\" data-col-size=\"sm\">LSZH \/ PE \/ PVC<\/td>\n<\/tr>\n<tr data-start=\"1936\" data-end=\"1978\">\n<td data-start=\"1936\" data-end=\"1949\" data-col-size=\"sm\">Conformidad<\/td>\n<td data-start=\"1949\" data-end=\"1978\" data-col-size=\"sm\">IEC, TIA-568, RoHS, REACH<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1980\" data-end=\"1983\" \/>\n<h3 data-start=\"1985\" data-end=\"2037\"><strong data-start=\"1989\" data-end=\"2037\">Dise\u00f1ado para venta al por mayor, OEM y suministro para proyectos.<\/strong><\/h3>\n<p data-start=\"2039\" data-end=\"2071\">Este modelo es ampliamente utilizado por:<\/p>\n<ul data-start=\"2073\" data-end=\"2243\">\n<li data-start=\"2073\" data-end=\"2108\">\n<p data-start=\"2075\" data-end=\"2108\"><strong data-start=\"2075\" data-end=\"2108\">Distribuidores de telecomunicaciones y CATV<\/strong><\/p>\n<\/li>\n<li data-start=\"2109\" data-end=\"2138\">\n<p data-start=\"2111\" data-end=\"2138\"><strong data-start=\"2111\" data-end=\"2138\">Contratistas de FTTH y FTTx<\/strong><\/p>\n<\/li>\n<li data-start=\"2139\" data-end=\"2163\">\n<p data-start=\"2141\" data-end=\"2163\"><strong data-start=\"2141\" data-end=\"2163\">Integradores de sistemas<\/strong><\/p>\n<\/li>\n<li data-start=\"2164\" data-end=\"2197\">\n<p data-start=\"2166\" data-end=\"2197\"><strong data-start=\"2166\" data-end=\"2197\">Proveedores de equipos de red<\/strong><\/p>\n<\/li>\n<li data-start=\"2198\" data-end=\"2243\">\n<p data-start=\"2200\" data-end=\"2243\"><strong data-start=\"2200\" data-end=\"2243\">Exportadores globales y empresas de abastecimiento<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2245\" data-end=\"2256\">Apoyamos:<\/p>\n<ul data-start=\"2257\" data-end=\"2406\">\n<li data-start=\"2257\" data-end=\"2274\">\n<p data-start=\"2259\" data-end=\"2274\"><strong data-start=\"2259\" data-end=\"2274\">Pedidos al por mayor<\/strong><\/p>\n<\/li>\n<li data-start=\"2275\" data-end=\"2293\">\n<p data-start=\"2277\" data-end=\"2293\"><strong data-start=\"2277\" data-end=\"2293\">Cantidad m\u00ednima de pedido flexible<\/strong><\/p>\n<\/li>\n<li data-start=\"2294\" data-end=\"2318\">\n<p data-start=\"2296\" data-end=\"2318\"><strong data-start=\"2296\" data-end=\"2318\">Marca OEM\/ODM<\/strong><\/p>\n<\/li>\n<li data-start=\"2319\" data-end=\"2351\">\n<p data-start=\"2321\" data-end=\"2351\"><strong data-start=\"2321\" data-end=\"2351\">Longitudes y empaques personalizados<\/strong><\/p>\n<\/li>\n<li data-start=\"2352\" data-end=\"2380\">\n<p data-start=\"2354\" data-end=\"2380\"><strong data-start=\"2354\" data-end=\"2380\">Precios directos de f\u00e1brica<\/strong><\/p>\n<\/li>\n<li data-start=\"2381\" data-end=\"2406\">\n<p data-start=\"2383\" data-end=\"2406\"><strong data-start=\"2383\" data-end=\"2406\">Log\u00edstica mundial<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2408\" data-end=\"2411\" \/>\n<h3 data-start=\"2413\" data-end=\"2464\"><strong data-start=\"2417\" data-end=\"2464\">Por qu\u00e9 APC + Armoured es el est\u00e1ndar del sector<\/strong><\/h3>\n<p data-start=\"2466\" data-end=\"2552\">Los conectores APC reducen dr\u00e1sticamente <strong data-start=\"2500\" data-end=\"2527\">reflexi\u00f3n \u00f3ptica trasera<\/strong>, que es esencial para:<\/p>\n<ul data-start=\"2553\" data-end=\"2642\">\n<li data-start=\"2553\" data-end=\"2563\">\n<p data-start=\"2555\" data-end=\"2563\"><strong data-start=\"2555\" data-end=\"2563\">CATV<\/strong><\/p>\n<\/li>\n<li data-start=\"2564\" data-end=\"2583\">\n<p data-start=\"2566\" data-end=\"2583\"><strong data-start=\"2566\" data-end=\"2583\">RF sobre fibra<\/strong><\/p>\n<\/li>\n<li data-start=\"2584\" data-end=\"2611\">\n<p data-start=\"2586\" data-end=\"2611\"><strong data-start=\"2586\" data-end=\"2611\">Redes PON y FTTx<\/strong><\/p>\n<\/li>\n<li data-start=\"2612\" data-end=\"2642\">\n<p data-start=\"2614\" data-end=\"2642\"><strong data-start=\"2614\" data-end=\"2642\">Sistemas l\u00e1ser de alta potencia<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2644\" data-end=\"2802\">En <strong data-start=\"2648\" data-end=\"2670\">estructura blindada<\/strong> garantiza una fiabilidad a largo plazo en <strong data-start=\"2704\" data-end=\"2727\">instalaciones de campo<\/strong>, bajando <strong data-start=\"2738\" data-end=\"2771\">costo de mantenimiento y tiempo de inactividad<\/strong> para operadores e integradores.<\/p>\n<hr data-start=\"2804\" data-end=\"2807\" \/>\n<h2 data-start=\"2809\" data-end=\"2832\"><strong data-start=\"2812\" data-end=\"2832\">Preguntas frecuentes profesionales<\/strong><\/h2>\n<p data-start=\"2834\" data-end=\"2965\"><strong data-start=\"2834\" data-end=\"2891\">P1: \u00bfEste cable es adecuado para redes FTTH y PON?<\/strong><br data-start=\"2891\" data-end=\"2894\" \/>S\u00ed. Es totalmente compatible con <strong data-start=\"2927\" data-end=\"2964\">Sistemas GPON, XG-PON y XGS-PON<\/strong>.<\/p>\n<p data-start=\"2967\" data-end=\"3116\"><strong data-start=\"2967\" data-end=\"3018\">P2: \u00bfSe pueden mezclar conectores APC con puertos UPC?<\/strong><br data-start=\"3018\" data-end=\"3021\" \/>No. <strong data-start=\"3025\" data-end=\"3060\">APC y UPC nunca deben mezclarse.<\/strong>\u2014hacerlo puede da\u00f1ar los conectores y reducir el rendimiento.<\/p>\n<p data-start=\"3118\" data-end=\"3239\"><strong data-start=\"3118\" data-end=\"3163\">P3: \u00bfSe ofrece la opci\u00f3n de marca de fabricante (OEM) o marca privada?<\/strong><br data-start=\"3163\" data-end=\"3166\" \/>S\u00ed. Ofrecemos <strong data-start=\"3182\" data-end=\"3238\">OEM, ODM, marca privada y empaque personalizado.<\/strong>.<\/p>\n<p data-start=\"3241\" data-end=\"3376\"><strong data-start=\"3241\" data-end=\"3283\">P4: \u00bfCu\u00e1l es la cantidad m\u00ednima de pedido para el abastecimiento a granel?<\/strong><br data-start=\"3283\" data-end=\"3286\" \/>El MOQ es <strong data-start=\"3293\" data-end=\"3305\">flexible<\/strong>, que admite tanto <strong data-start=\"3323\" data-end=\"3375\">Pedidos de prueba peque\u00f1os e implementaciones de proyectos grandes.<\/strong>.<\/p>\n<p data-start=\"3378\" data-end=\"3526\"><strong data-start=\"3378\" data-end=\"3428\">P5: \u00bfAfecta el blindaje al rendimiento \u00f3ptico?<\/strong><br data-start=\"3428\" data-end=\"3431\" \/>No. El blindaje proporciona <strong data-start=\"3454\" data-end=\"3484\">solo protecci\u00f3n mec\u00e1nica<\/strong> y hace <strong data-start=\"3494\" data-end=\"3525\">no aumentar la p\u00e9rdida de inserci\u00f3n<\/strong>.<\/p>\n<p data-start=\"3528\" data-end=\"3695\"><strong data-start=\"3528\" data-end=\"3584\">P6: \u00bfQu\u00e9 tipo de clientes suelen comprar este cable?<\/strong><br data-start=\"3584\" data-end=\"3587\" \/>Lo compran habitualmente <strong data-start=\"3615\" data-end=\"3694\">operadores de telecomunicaciones, proveedores de CATV, contratistas de FTTH e integradores de sistemas<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p data-start=\"66\" data-end=\"320\">En <strong data-start=\"70\" data-end=\"113\">Cable de conexi\u00f3n de fibra blindado FC\/APC\u2013SC\/APC<\/strong> es un <strong data-start=\"119\" data-end=\"169\">puente \u00f3ptico de alto rendimiento y calidad de operador<\/strong> dise\u00f1ado para <strong data-start=\"183\" data-end=\"249\">Redes PON, sistemas CATV e infraestructura de telecomunicaciones exterior.<\/strong> d\u00f3nde <strong data-start=\"256\" data-end=\"304\">Reflexi\u00f3n ultrabaja y durabilidad f\u00edsica.<\/strong> son fundamentales.<\/p>\n<p data-start=\"322\" data-end=\"575\">Con <strong data-start=\"332\" data-end=\"372\">Conectores FC y SC pulidos con APC de 8\u00b0<\/strong> combinado con un <strong data-start=\"389\" data-end=\"423\">estructura de cable con blindaje met\u00e1lico<\/strong>, este cable de conexi\u00f3n ofrece <strong data-start=\"450\" data-end=\"479\">pureza excepcional de la se\u00f1al<\/strong> mientras resiste <strong data-start=\"499\" data-end=\"574\">aplastamiento, vibraci\u00f3n, da\u00f1os causados por roedores y entornos de instalaci\u00f3n adversos<\/strong>.<\/p>\n<p data-start=\"577\" data-end=\"733\">Como <strong data-start=\"582\" data-end=\"636\">fabricante directo de f\u00e1brica y exportador mayorista<\/strong>, apoyamos <strong data-start=\"649\" data-end=\"723\">OEM, ODM, distribuidores, integradores de sistemas y proyectos de abastecimiento a granel.<\/strong> a nivel mundial.<\/p>","protected":false},"featured_media":714,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[44],"product_tag":[],"class_list":["post-713","product","type-product","status-publish","has-post-thumbnail","product_cat-multimode-fiber-optic-patch-cord","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product\/713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/comments?post=713"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media\/714"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/media?parent=713"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_brand?post=713"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_cat?post=713"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/es\/wp-json\/wp\/v2\/product_tag?post=713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}