<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Connecteurs duplex LC (monomode et multimode) - Fenxi Optoelectronics Technology</title>
	<atom:link href="https://www.fenxifiber.com/fr/product-category/lc-connector/lc-duplex-connectors-single-modemultimode/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.fenxifiber.com/fr</link>
	<description></description>
	<lastbuilddate>Thu, 05 Feb 2026 02:37:21 +0000</lastbuilddate>
	<language>fr-FR</language>
	<sy:updateperiod>
	horaire	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.fenxifiber.com/wp-content/uploads/2026/01/FENXI-LOGO-F-100x100.jpg</url>
	<title>Connecteurs duplex LC (monomode et multimode) - Fenxi Optoelectronics Technology</title>
	<link>https://www.fenxifiber.com/fr</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Connecteur fibre optique LC UPC 3.0mm Duplex Multimode (bleu lac)</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-lake-blue/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-lake-blue/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 03:02:57 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=890</guid>

					<description><![CDATA[<p data-start="180" data-end="551">Dans les grands centres de données et les salles de fibre optique des entreprises, les câbles ne sont plus de simples connexions - ils sont <strong data-start="279" data-end="312">partie du système de gestion</strong>.<br data-start="313" data-end="316" />Le <strong data-start="320" data-end="387">Connecteur fibre optique LC UPC 3.0mm Duplex Multimode (bleu lac)</strong> ajoute <strong data-start="393" data-end="424">une identification visuelle claire</strong> à un <strong data-start="430" data-end="457">liaison optique à haut débit</strong>, permettant aux ingénieurs de distinguer rapidement les circuits multimodes des circuits monomodes et des itinéraires de secours.</p>
<p data-start="553" data-end="714">Le <strong data-start="557" data-end="577">Veste Lake Blue</strong> est couramment utilisé pour identifier les <strong data-start="607" data-end="638">Fibre multimode OM3 et OM4</strong>, Le système d'alimentation en eau de l'appareil permet de réduire le risque de mauvaises connexions lors de l'installation ou de l'entretien.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="721" data-end="780">Le code couleur multimode facilite la gestion des réseaux</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="782" data-end="992">
<thead data-start="782" data-end="827">
<tr data-start="782" data-end="827">
<th class="" data-start="782" data-end="797" data-col-size="sm">Couleur de la veste</th>
<th class="" data-start="797" data-end="827" data-col-size="sm">Ce qu'il représente généralement</th>
</tr>
</thead>
<tbody data-start="873" data-end="992">
<tr data-start="873" data-end="897">
<td data-start="873" data-end="882" data-col-size="sm">Jaune</td>
<td data-start="882" data-end="897" data-col-size="sm">monomode</td>
</tr>
<tr data-start="898" data-end="930">
<td data-start="898" data-end="907" data-col-size="sm">Orange</td>
<td data-start="907" data-end="930" data-col-size="sm">OM1 / OM2 multimode</td>
</tr>
<tr data-start="931" data-end="992">
<td data-start="931" data-end="954" data-col-size="sm"><strong data-start="933" data-end="953">Bleu lac (Aqua)</strong></td>
<td data-col-size="sm" data-start="954" data-end="992"><strong data-start="956" data-end="990">OM3 / OM4 multimode à grande vitesse</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="994" data-end="1086">Cette norme visuelle est largement utilisée dans <strong data-start="1033" data-end="1085">les centres de données, les installations en nuage et les salles de télécommunications</strong>.</p>
<hr data-start="1088" data-end="1091" />
<h3 data-start="1093" data-end="1142">3.0mm duplex - conçu pour le câblage structuré</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1144" data-end="1307">
<thead data-start="1144" data-end="1173">
<tr data-start="1144" data-end="1173">
<th class="" data-start="1144" data-end="1157" data-col-size="sm">Taille du câble</th>
<th class="" data-start="1157" data-end="1173" data-col-size="md">Rôle typique</th>
</tr>
</thead>
<tbody data-start="1203" data-end="1307">
<tr data-start="1203" data-end="1242">
<td data-start="1203" data-end="1211" data-col-size="sm">2,0 mm</td>
<td data-col-size="md" data-start="1211" data-end="1242">Cordons de raccordement aux ports des commutateurs</td>
</tr>
<tr data-start="1243" data-end="1307">
<td data-start="1243" data-end="1255" data-col-size="sm"><strong data-start="1245" data-end="1254">3,0 mm</strong></td>
<td data-start="1255" data-end="1307" data-col-size="md"><strong data-start="1257" data-end="1305">Baies, chemins de câbles, liaisons d'armoire à armoire</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1309" data-end="1432">La gaine plus épaisse protège les fibres multimodes de la perte de courbure et des contraintes physiques lorsqu'elles sont acheminées dans des chemins de câblage denses.</p>
<hr data-start="1434" data-end="1437" />
<h3 data-start="1439" data-end="1474">Performance optique multimode</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1476" data-end="1727">
<thead data-start="1476" data-end="1505">
<tr data-start="1476" data-end="1505">
<th class="" data-start="1476" data-end="1488" data-col-size="sm">Paramètres</th>
<th class="" data-start="1488" data-end="1505" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1535" data-end="1727">
<tr data-start="1535" data-end="1561">
<td data-start="1535" data-end="1548" data-col-size="sm">Type de fibre</td>
<td data-start="1548" data-end="1561" data-col-size="sm">OM3 / OM4</td>
</tr>
<tr data-start="1562" data-end="1587">
<td data-start="1562" data-end="1574" data-col-size="sm">Taille du noyau</td>
<td data-start="1574" data-end="1587" data-col-size="sm">50/125 µm</td>
</tr>
<tr data-start="1588" data-end="1606">
<td data-start="1588" data-end="1599" data-col-size="sm">Face d'extrémité</td>
<td data-start="1599" data-end="1606" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1607" data-end="1637">
<td data-start="1607" data-end="1624" data-col-size="sm">Perte d'insertion</td>
<td data-col-size="sm" data-start="1624" data-end="1637">≤ 0,30 dB</td>
</tr>
<tr data-start="1638" data-end="1663">
<td data-start="1638" data-end="1652" data-col-size="sm">Perte de retour</td>
<td data-start="1652" data-end="1663" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1664" data-end="1695">
<td data-start="1664" data-end="1678" data-col-size="sm">Longueurs d'onde</td>
<td data-start="1678" data-end="1695" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1696" data-end="1727">
<td data-start="1696" data-end="1710" data-col-size="sm">Vie féconde</td>
<td data-start="1710" data-end="1727" data-col-size="sm">≥ 1000 cycles</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1729" data-end="1834">Ces caractéristiques soutiennent <strong data-start="1759" data-end="1789">Ethernet 10G, 40G et 100G</strong> à l'intérieur des centres de données et des réseaux d'entreprise.</p>
<hr data-start="1836" data-end="1839" />
<h3 data-start="1841" data-end="1869">Construction LC duplex</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1871" data-end="2130">
<thead data-start="1871" data-end="1894">
<tr data-start="1871" data-end="1894">
<th class="" data-start="1871" data-end="1883" data-col-size="sm">Composant</th>
<th class="" data-start="1883" data-end="1894" data-col-size="sm">Objectif</th>
</tr>
</thead>
<tbody data-start="1917" data-end="2130">
<tr data-start="1917" data-end="1974">
<td data-start="1917" data-end="1943" data-col-size="sm">Embouts en céramique de 1,25 mm</td>
<td data-start="1943" data-end="1974" data-col-size="sm">Alignement multimode précis</td>
</tr>
<tr data-start="1975" data-end="2027">
<td data-start="1975" data-end="2000" data-col-size="sm">faces d'extrémité polies UPC</td>
<td data-start="2000" data-end="2027" data-col-size="sm">Couplage optique stable</td>
</tr>
<tr data-start="2028" data-end="2072">
<td data-start="2028" data-end="2045" data-col-size="sm">Clip LC duplex</td>
<td data-start="2045" data-end="2072" data-col-size="sm">Maintient l'appariement Tx/Rx</td>
</tr>
<tr data-start="2073" data-end="2130">
<td data-start="2073" data-end="2098" data-col-size="sm">Veste bleu lac 3.0mm</td>
<td data-start="2098" data-end="2130" data-col-size="sm">Haute visibilité et protection</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2132" data-end="2135" />
<h3 data-start="2137" data-end="2159">Questions et réponses professionnelles</h3>
<p data-start="2161" data-end="2328"><strong data-start="2161" data-end="2209">La couleur bleu lac affecte-t-elle les performances ?</strong><br data-start="2209" data-end="2212" />Non. La couleur est pour <strong data-start="2233" data-end="2271">identification et gestion uniquement</strong>. La performance optique est définie par la fibre et le polissage.</p>
<p data-start="2330" data-end="2456"><strong data-start="2330" data-end="2383">Est-il compatible avec les émetteurs-récepteurs OM3 et OM4 ?</strong><br data-start="2383" data-end="2386" />Oui, il est conçu spécifiquement pour <strong data-start="2423" data-end="2455">systèmes multimodes à grande vitesse</strong>.</p>
<p data-start="2458" data-end="2564"><strong data-start="2458" data-end="2498">Peut-on l'utiliser dans les panneaux de brassage LC ?</strong><br data-start="2498" data-end="2501" />Oui, l'interface LC est standard et s'adapte à tous les adaptateurs LC UPC.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-lake-blue/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 3.0mm Duplex Multimode Fiber Optic Connector</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 03:01:52 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=887</guid>

					<description><![CDATA[<p data-start="161" data-end="572">Le <strong data-start="165" data-end="220">LC UPC 3.0mm Duplex Multimode Fiber Optic Connector</strong> est conçu pour <strong data-start="234" data-end="275">les centres de données et les réseaux d'entreprise</strong> où les liaisons optiques à courte portée doivent rester rapides, stables et physiquement protégées.<br data-start="358" data-end="361" />La fibre multimode est largement utilisée pour <strong data-start="396" data-end="429">Connexions 10G, 40G et 100G</strong>, et la gaine duplex plus épaisse de 3,0 mm confère à ces liens la qualité d'un produit de haute qualité. <strong data-start="489" data-end="515">fiabilité mécanique</strong> Ils sont acheminés à travers des plateaux, des racks et des armoires.</p>
<p data-start="574" data-end="725">Alors que les cavaliers standard de 2,0 mm fonctionnent bien au niveau des ports d'équipement, les chemins du réseau fédérateur nécessitent des cavaliers de 2,0 mm. <strong data-start="656" data-end="676">des vestes plus résistantes</strong> pour éviter les micro-courbures et l'instabilité du signal.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="732" data-end="776">L'importance de 3,0 mm dans le câblage multimode</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="778" data-end="946">
<thead data-start="778" data-end="812">
<tr data-start="778" data-end="812">
<th class="" data-start="778" data-end="795" data-col-size="sm">Diamètre du câble</th>
<th class="" data-start="795" data-end="812" data-col-size="sm">Utilisation pratique</th>
</tr>
</thead>
<tbody data-start="847" data-end="946">
<tr data-start="847" data-end="887">
<td data-start="847" data-end="855" data-col-size="sm">2,0 mm</td>
<td data-start="855" data-end="887" data-col-size="sm">Ports de commutation et d'émission-réception</td>
</tr>
<tr data-start="888" data-end="946">
<td data-start="888" data-end="900" data-col-size="sm"><strong data-start="890" data-end="899">3,0 mm</strong></td>
<td data-col-size="sm" data-start="900" data-end="946"><strong data-start="902" data-end="944">Rayonnages, plateaux, liaisons d'armoire à armoire</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="948" data-end="1046">La gaine plus lourde protège la fibre OM de la perte de flexion et de l'écrasement dans les chemins de câbles encombrés.</p>
<hr data-start="1048" data-end="1051" />
<h3 data-start="1053" data-end="1085">Comportement optique multimode</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1087" data-end="1359">
<thead data-start="1087" data-end="1116">
<tr data-start="1087" data-end="1116">
<th class="" data-start="1087" data-end="1099" data-col-size="sm">Paramètres</th>
<th class="" data-start="1099" data-end="1116" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1146" data-end="1359">
<tr data-start="1146" data-end="1178">
<td data-start="1146" data-end="1159" data-col-size="sm">Type de fibre</td>
<td data-start="1159" data-end="1178" data-col-size="sm">OM2 / OM3 / OM4</td>
</tr>
<tr data-start="1179" data-end="1219">
<td data-start="1179" data-end="1191" data-col-size="sm">Taille du noyau</td>
<td data-start="1191" data-end="1219" data-col-size="sm">50/125 µm ou 62,5/125 µm</td>
</tr>
<tr data-start="1220" data-end="1238">
<td data-start="1220" data-end="1231" data-col-size="sm">Face d'extrémité</td>
<td data-start="1231" data-end="1238" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1239" data-end="1269">
<td data-start="1239" data-end="1256" data-col-size="sm">Perte d'insertion</td>
<td data-start="1256" data-end="1269" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1270" data-end="1295">
<td data-start="1270" data-end="1284" data-col-size="sm">Perte de retour</td>
<td data-start="1284" data-end="1295" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1296" data-end="1327">
<td data-start="1296" data-end="1310" data-col-size="sm">Longueurs d'onde</td>
<td data-start="1310" data-end="1327" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1328" data-end="1359">
<td data-start="1328" data-end="1342" data-col-size="sm">Vie féconde</td>
<td data-start="1342" data-end="1359" data-col-size="sm">≥ 1000 cycles</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1361" data-end="1469">Ces valeurs soutiennent <strong data-start="1382" data-end="1436">Ethernet, SAN et interconnexions optiques à haut débit</strong> à l'intérieur des bâtiments et des salles de données.</p>
<hr data-start="1471" data-end="1474" />
<h3 data-start="1476" data-end="1498">Conception LC duplex</h3>
<p data-start="1500" data-end="1639">Deux fibres sont maintenues dans un boîtier LC duplex, ce qui garantit <strong data-start="1555" data-end="1614">polarité stable et synchronisation des voies d'émission et de réception</strong> même pendant la maintenance.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1641" data-end="1895">
<thead data-start="1641" data-end="1663">
<tr data-start="1641" data-end="1663">
<th class="" data-start="1641" data-end="1651" data-col-size="sm">Élément</th>
<th class="" data-start="1651" data-end="1663" data-col-size="sm">Fonction</th>
</tr>
</thead>
<tbody data-start="1685" data-end="1895">
<tr data-start="1685" data-end="1738">
<td data-start="1685" data-end="1711" data-col-size="sm">Embouts en céramique de 1,25 mm</td>
<td data-start="1711" data-end="1738" data-col-size="sm">Alignement précis des fibres</td>
</tr>
<tr data-start="1739" data-end="1791">
<td data-start="1739" data-end="1752" data-col-size="sm">Polissage UPC</td>
<td data-col-size="sm" data-start="1752" data-end="1791">Faible réflexion pour les lasers multimodes</td>
</tr>
<tr data-start="1792" data-end="1833">
<td data-start="1792" data-end="1809" data-col-size="sm">Clip LC duplex</td>
<td data-col-size="sm" data-start="1809" data-end="1833">Verrouille les Tx/Rx ensemble</td>
</tr>
<tr data-start="1834" data-end="1895">
<td data-start="1834" data-end="1855" data-col-size="sm">Gaine épaisse de 3,0 mm</td>
<td data-start="1855" data-end="1895" data-col-size="sm">Protège contre la flexion et la tension</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1897" data-end="1900" />
<h3 data-start="1902" data-end="1924">Questions et réponses professionnelles</h3>
<p data-start="1926" data-end="2090"><strong data-start="1926" data-end="1967">3,0 mm est-il trop rigide pour les connecteurs LC ?</strong><br data-start="1967" data-end="1970" />Non. La bague LC et le boîtier sont standard. Seul le câble est plus épais, offrant une meilleure protection pour les routes dorsales.</p>
<p data-start="2092" data-end="2205"><strong data-start="2092" data-end="2136">Peut-on l'utiliser avec des fibres OM3 et OM4 ?</strong><br data-start="2136" data-end="2139" />Oui, il est entièrement compatible avec les fibres multimodes OM2, OM3 et OM4.</p>
<p data-start="2207" data-end="2337"><strong data-start="2207" data-end="2248">Dois-je utiliser l'APC pour les liaisons multimodes ?</strong><br data-start="2248" data-end="2251" />Non. Les systèmes multimodes utilisent <strong data-start="2277" data-end="2284">CUP</strong>. L'APC est conçu pour le contrôle de la réflexion en mode unique.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Connecteur fibre optique monomode duplex LC UPC 3.0mm</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-monomode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-monomode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 03:00:39 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=885</guid>

					<description><![CDATA[<p data-start="164" data-end="520">Le <strong data-start="168" data-end="224">Connecteur fibre optique monomode duplex LC UPC 3.0mm</strong> est conçu pour <strong data-start="241" data-end="288">les liaisons par fibre optique qui doivent rester stables pendant des années</strong>, non seulement à l'intérieur d'une étagère, mais aussi dans l'ensemble de l'entreprise. <strong data-start="324" data-end="365">étages, couloirs et trames dorsales</strong>.<br data-start="366" data-end="369" />Où les cordons de raccordement sont acheminés à travers <strong data-start="406" data-end="463">chemins de câbles, gaines verticales ou armoires de distribution</strong>, Une veste plus épaisse et plus protectrice devient alors indispensable.</p>
<p data-start="522" data-end="730">Ce connecteur LC duplex de 3,0 mm combine <strong data-start="562" data-end="588">polissage UPC à faible perte</strong> avec un <strong data-start="596" data-end="626">structure de câble renforcée</strong>, Le système de gestion de l'information permet d'établir une connexion fiable entre les <strong data-start="667" data-end="729">les répartiteurs optiques, les commutateurs et les équipements d'accès</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="737" data-end="786">3.0mm duplex - conçu pour les chemins de câbles réels</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="788" data-end="982">
<thead data-start="788" data-end="827">
<tr data-start="788" data-end="827">
<th class="" data-start="788" data-end="801" data-col-size="sm">Type de câble</th>
<th class="" data-start="801" data-end="827" data-col-size="md">Là où il est le plus performant</th>
</tr>
</thead>
<tbody data-start="867" data-end="982">
<tr data-start="867" data-end="908">
<td data-start="867" data-end="875" data-col-size="sm">2,0 mm</td>
<td data-start="875" data-end="908" data-col-size="md">Court-circuitage des cavaliers sur les ports de l'appareil</td>
</tr>
<tr data-start="909" data-end="982">
<td data-start="909" data-end="921" data-col-size="sm"><strong data-start="911" data-end="920">3,0 mm</strong></td>
<td data-start="921" data-end="982" data-col-size="md"><strong data-start="923" data-end="980">Backbones de bâtiments, liaisons d'étage à étage, routage ODF</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="984" data-end="1094">La gaine plus épaisse absorbe les forces de traction et réduit les micro-courbures lorsque les fibres sont acheminées sur de longues distances.</p>
<hr data-start="1096" data-end="1099" />
<h3 data-start="1101" data-end="1143">Caractéristiques de transmission optique</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1145" data-end="1396">
<thead data-start="1145" data-end="1174">
<tr data-start="1145" data-end="1174">
<th class="" data-start="1145" data-end="1157" data-col-size="sm">Paramètres</th>
<th class="" data-start="1157" data-end="1174" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1204" data-end="1396">
<tr data-start="1204" data-end="1236">
<td data-start="1204" data-end="1212" data-col-size="sm">Fibre</td>
<td data-start="1212" data-end="1236" data-col-size="sm">monomode 9/125 µm</td>
</tr>
<tr data-start="1237" data-end="1258">
<td data-start="1237" data-end="1251" data-col-size="sm">Type de polonais</td>
<td data-start="1251" data-end="1258" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1259" data-end="1289">
<td data-start="1259" data-end="1276" data-col-size="sm">Perte d'insertion</td>
<td data-start="1276" data-end="1289" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1290" data-end="1315">
<td data-start="1290" data-end="1304" data-col-size="sm">Perte de retour</td>
<td data-start="1304" data-end="1315" data-col-size="sm">≥ 50 dB</td>
</tr>
<tr data-start="1316" data-end="1358">
<td data-start="1316" data-end="1340" data-col-size="sm">Longueurs d'onde de fonctionnement</td>
<td data-start="1340" data-end="1358" data-col-size="sm">1310 / 1550 nm</td>
</tr>
<tr data-start="1359" data-end="1396">
<td data-start="1359" data-end="1379" data-col-size="sm">Durabilité de l'accouplement</td>
<td data-start="1379" data-end="1396" data-col-size="sm">≥ 1000 cycles</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1398" data-end="1496">Ces valeurs soutiennent <strong data-start="1419" data-end="1463">Ethernet, SDH, réseaux métropolitains et d'accès</strong> avec une stabilité du signal à long terme.</p>
<hr data-start="1498" data-end="1501" />
<h3 data-start="1503" data-end="1528">Structure LC duplex</h3>
<p data-start="1530" data-end="1659">Deux fibres sont fixées à l'intérieur d'un boîtier LC duplex, ce qui garantit <strong data-start="1590" data-end="1619">orientation correcte Tx/Rx</strong> même lorsque les câbles sont déplacés ou entretenus.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1661" data-end="1899">
<thead data-start="1661" data-end="1687">
<tr data-start="1661" data-end="1687">
<th class="" data-start="1661" data-end="1676" data-col-size="sm">La construction</th>
<th class="" data-start="1676" data-end="1687" data-col-size="sm">Bénéfice</th>
</tr>
</thead>
<tbody data-start="1713" data-end="1899">
<tr data-start="1713" data-end="1765">
<td data-start="1713" data-end="1739" data-col-size="sm">Embouts en céramique de 1,25 mm</td>
<td data-col-size="sm" data-start="1739" data-end="1765">Alignement précis du noyau</td>
</tr>
<tr data-start="1766" data-end="1809">
<td data-start="1766" data-end="1791" data-col-size="sm">faces d'extrémité polies UPC</td>
<td data-col-size="sm" data-start="1791" data-end="1809">Faible réflexion</td>
</tr>
<tr data-start="1810" data-end="1849">
<td data-start="1810" data-end="1827" data-col-size="sm">Clip LC duplex</td>
<td data-col-size="sm" data-start="1827" data-end="1849">Maintien de la polarité</td>
</tr>
<tr data-start="1850" data-end="1899">
<td data-start="1850" data-end="1871" data-col-size="sm">Gaine épaisse de 3,0 mm</td>
<td data-start="1871" data-end="1899" data-col-size="sm">Protège contre les tensions</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1901" data-end="1904" />
<h3 data-start="1906" data-end="1928">Questions et réponses professionnelles</h3>
<p data-start="1930" data-end="2085"><strong data-start="1930" data-end="1978">Quand dois-je choisir 3,0 mm au lieu de 2,0 mm ?</strong><br data-start="1978" data-end="1981" />Lorsque le cavalier traverse <strong data-start="2010" data-end="2053">les chemins de câbles, les colonnes montantes ou les cadres de la dorsale</strong> où il risque d'être plié ou tiré.</p>
<p data-start="2087" data-end="2216"><strong data-start="2087" data-end="2135">Est-il compatible avec tous les adaptateurs LC UPC ?</strong><br data-start="2135" data-end="2138" />Oui, l'interface LC est standard et s'adapte à tous les panneaux UPC LC et à tous les émetteurs-récepteurs.</p>
<p data-start="2218" data-end="2353"><strong data-start="2218" data-end="2255">Peut-on l'utiliser pour les systèmes PON ?</strong><br data-start="2255" data-end="2258" />Oui, mais pour les systèmes PON à superposition RF ou sensibles à la réflexion, <strong data-start="2319" data-end="2329">LC APC</strong> est recommandé.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-monomode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Duplex Multimode (Bleu lac)</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-lake-blue/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-lake-blue/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:59:35 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=882</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-lake-blue/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Duplex Multimode Fiber Optic Connector</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:58:35 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=880</guid>

					<description><![CDATA[<p data-start="162" data-end="539">Le <strong data-start="166" data-end="221">LC UPC 2.0mm Duplex Multimode Fiber Optic Connector</strong> est conçu pour <strong data-start="238" data-end="296">liaisons optiques à grande largeur de bande, de courte à moyenne distance</strong> à l'intérieur des centres de données, des réseaux d'entreprise et des systèmes de contrôle industriel.<br data-start="369" data-end="372" />La fibre multimode est choisie lorsque <strong data-start="404" data-end="444">vitesse, stabilité et rentabilité</strong> Le connecteur LC duplex permet d'atteindre cet équilibre.</p>
<p data-start="541" data-end="707">Avec <strong data-start="546" data-end="574">Embouts LC polis UPC</strong>, il garantit <strong data-start="587" data-end="636">contact physique étroit et faible perte d'insertion</strong>, Il s'agit donc d'une solution idéale pour <strong data-start="658" data-end="706">Canaux optiques multimodes 10G, 40G et 100G</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="714" data-end="772">Multimode duplex - conçu pour un flux de données bidirectionnel</h3>
<p data-start="774" data-end="963">Les émetteurs-récepteurs multimodes nécessitent toujours <strong data-start="812" data-end="848">deux fibres : transmission et réception</strong>.<br data-start="849" data-end="852" />La structure LC duplex les maintient verrouillés ensemble, ce qui évite les inversions de polarité et simplifie le raccordement à l'intérieur :</p>
<ul data-start="965" data-end="1053">
<li data-start="965" data-end="981">
<p data-start="967" data-end="981">Baies de serveurs</p>
</li>
<li data-start="982" data-end="999">
<p data-start="984" data-end="999">Trames de commutation</p>
</li>
<li data-start="1000" data-end="1020">
<p data-start="1002" data-end="1020">Réseaux de stockage</p>
</li>
<li data-start="1021" data-end="1053">
<p data-start="1023" data-end="1053">Armoires Ethernet industrielles</p>
</li>
</ul>
<p data-start="1055" data-end="1144">Dans les environnements à haute densité, le duplex LC permet <strong data-start="1102" data-end="1126">deux fois le nombre de ports</strong> de connecteurs SC.</p>
<hr data-start="1146" data-end="1149" />
<h3 data-start="1151" data-end="1193">Gaine de 2,0 mm - flexible mais fiable</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1195" data-end="1372">
<thead data-start="1195" data-end="1228">
<tr data-start="1195" data-end="1228">
<th class="" data-start="1195" data-end="1208" data-col-size="sm">Taille du câble</th>
<th class="" data-start="1208" data-end="1228" data-col-size="sm">Ce qu'il apporte</th>
</tr>
</thead>
<tbody data-start="1261" data-end="1372">
<tr data-start="1261" data-end="1290">
<td data-start="1261" data-end="1269" data-col-size="sm">0,9 mm</td>
<td data-start="1269" data-end="1290" data-col-size="sm">Épissure, fragile</td>
</tr>
<tr data-start="1291" data-end="1346">
<td data-start="1291" data-end="1303" data-col-size="sm"><strong data-start="1293" data-end="1302">2,0 mm</strong></td>
<td data-start="1303" data-end="1346" data-col-size="sm"><strong data-start="1305" data-end="1344">Patching en direct, émetteurs-récepteurs, panneaux</strong></td>
</tr>
<tr data-start="1347" data-end="1372">
<td data-start="1347" data-end="1355" data-col-size="sm">3,0 mm</td>
<td data-start="1355" data-end="1372" data-col-size="sm">Routage lourd</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1374" data-end="1517">Le câble de 2,0 mm est optimisé pour <strong data-start="1407" data-end="1462">enfichage fréquent et routage serré derrière les ports LC</strong>, ce qui en fait la norme de l'industrie en matière d'équipement actif.</p>
<hr data-start="1519" data-end="1522" />
<h3 data-start="1524" data-end="1559">Performance optique multimode</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1561" data-end="1841">
<thead data-start="1561" data-end="1590">
<tr data-start="1561" data-end="1590">
<th class="" data-start="1561" data-end="1573" data-col-size="sm">Paramètres</th>
<th class="" data-start="1573" data-end="1590" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1620" data-end="1841">
<tr data-start="1620" data-end="1662">
<td data-start="1620" data-end="1633" data-col-size="sm">Type de fibre</td>
<td data-start="1633" data-end="1662" data-col-size="sm">OM2 / OM3 / OM4 multimode</td>
</tr>
<tr data-start="1663" data-end="1703">
<td data-start="1663" data-end="1675" data-col-size="sm">Taille du noyau</td>
<td data-start="1675" data-end="1703" data-col-size="sm">50/125 µm ou 62,5/125 µm</td>
</tr>
<tr data-start="1704" data-end="1720">
<td data-start="1704" data-end="1713" data-col-size="sm">Polonais</td>
<td data-start="1713" data-end="1720" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1721" data-end="1751">
<td data-start="1721" data-end="1738" data-col-size="sm">Perte d'insertion</td>
<td data-start="1738" data-end="1751" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1752" data-end="1777">
<td data-start="1752" data-end="1766" data-col-size="sm">Perte de retour</td>
<td data-start="1766" data-end="1777" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1778" data-end="1809">
<td data-start="1778" data-end="1792" data-col-size="sm">Longueurs d'onde</td>
<td data-start="1792" data-end="1809" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1810" data-end="1841">
<td data-start="1810" data-end="1823" data-col-size="sm">Durabilité</td>
<td data-start="1823" data-end="1841" data-col-size="sm">≥ 1000 accouplements</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1843" data-end="1929">Ces spécifications soutiennent <strong data-start="1872" data-end="1928">Ethernet, SAN et interconnexions optiques à courte portée</strong>.</p>
<hr data-start="1931" data-end="1934" />
<h3 data-start="1936" data-end="1962">A l'intérieur du connecteur</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1964" data-end="2216">
<thead data-start="1964" data-end="1988">
<tr data-start="1964" data-end="1988">
<th class="" data-start="1964" data-end="1976" data-col-size="sm">Composant</th>
<th class="" data-start="1976" data-end="1988" data-col-size="sm">Fonction</th>
</tr>
</thead>
<tbody data-start="2012" data-end="2216">
<tr data-start="2012" data-end="2064">
<td data-start="2012" data-end="2037" data-col-size="sm">Embout en céramique de 1,25 mm</td>
<td data-start="2037" data-end="2064" data-col-size="sm">Alignement précis des fibres</td>
</tr>
<tr data-start="2065" data-end="2119">
<td data-start="2065" data-end="2089" data-col-size="sm">Face d'extrémité polie UPC</td>
<td data-start="2089" data-end="2119" data-col-size="sm">Réduit la réflexion de Fresnel</td>
</tr>
<tr data-start="2120" data-end="2161">
<td data-start="2120" data-end="2137" data-col-size="sm">Clip LC duplex</td>
<td data-start="2137" data-end="2161" data-col-size="sm">Maintient l'ordre Tx/Rx</td>
</tr>
<tr data-start="2162" data-end="2216">
<td data-start="2162" data-end="2189" data-col-size="sm">Embout de décharge de traction de 2,0 mm</td>
<td data-start="2189" data-end="2216" data-col-size="sm">Prévient les dommages dus à la flexion</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2218" data-end="2221" />
<h3 data-start="2223" data-end="2245">Questions et réponses professionnelles</h3>
<p data-start="2247" data-end="2404"><strong data-start="2247" data-end="2297">Le multimode est-il adapté aux liaisons longue distance ?</strong><br data-start="2297" data-end="2300" />Non. Le multimode est optimisé pour <strong data-start="2331" data-end="2361">courtes et moyennes distances</strong> comme à l'intérieur des bâtiments et des centres de données.</p>
<p data-start="2406" data-end="2549"><strong data-start="2406" data-end="2462">Ce connecteur LC UPC peut-il être utilisé avec des adaptateurs APC ?</strong><br data-start="2462" data-end="2465" />Non. L'UPC et l'APC ne doivent pas être mélangés - les extrémités sont différentes et seront endommagées.</p>
<p data-start="2551" data-end="2743"><strong data-start="2551" data-end="2595">Pourquoi choisir le LC duplex au lieu du simplex ?</strong><br data-start="2595" data-end="2598" />Étant donné que les modules Ethernet et optiques nécessitent <strong data-start="2643" data-end="2667">transmission bidirectionnelle</strong>, et les connecteurs duplex garantissent <strong data-start="2698" data-end="2742">polarité correcte et installation plus rapide</strong>.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Connecteur fibre optique monomode duplex LC UPC 2.0mm</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-monomode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-monomode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:57:29 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=878</guid>

					<description><![CDATA[<p data-start="175" data-end="539">Dans les réseaux optiques modernes, la plupart des liaisons ne sont pas des liaisons longue distance, mais plutôt des liaisons à longue distance. <strong data-start="243" data-end="284">courtes, fréquentes et fortement connectées</strong>.<br data-start="285" data-end="288" />Dans les centres de données, les bureaux centraux et les salles d'équipement, les fibres sont constamment branchées, retirées et réarrangées.<br data-start="408" data-end="411" />Le <strong data-start="415" data-end="449">LC UPC 2.0mm Duplex monomode</strong> Le connecteur est conçu exactement pour ce type de <strong data-start="497" data-end="538">environnement à forte densité et à forte évolution</strong>.</p>
<p data-start="541" data-end="758">Son <strong data-start="545" data-end="563">Facteur de forme LC</strong> double la densité des ports par rapport aux connecteurs SC. <strong data-start="624" data-end="649">Face d'extrémité polie UPC</strong> assure <strong data-start="658" data-end="708">faible perte d'insertion et couplage optique stable</strong> pour une transmission monomode à 1310 nm et 1550 nm.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="765" data-end="832">Structure duplex - transmission et réception toujours appariées</h3>
<p data-start="834" data-end="1008">Les systèmes monomodes dépendent <strong data-start="864" data-end="895">des chemins bidirectionnels précis</strong>.<br data-start="896" data-end="899" />Avec le boîtier LC duplex, les deux fibres restent verrouillées ensemble, ce qui évite les erreurs de polarité lors de la connexion :</p>
<ul data-start="1010" data-end="1106">
<li data-start="1010" data-end="1029">
<p data-start="1012" data-end="1029">Interrupteur <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> interrupteur</p>
</li>
<li data-start="1030" data-end="1049">
<p data-start="1032" data-end="1049">Routeur <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> routeur</p>
</li>
<li data-start="1050" data-end="1078">
<p data-start="1052" data-end="1078">OLT <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> cadre de distribution</p>
</li>
<li data-start="1079" data-end="1106">
<p data-start="1081" data-end="1106">Serveur <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> système de stockage</p>
</li>
</ul>
<p data-start="1108" data-end="1172">Même en cas de maintenance, le lien reste organisé et traçable.</p>
<hr data-start="1174" data-end="1177" />
<h3 data-start="1179" data-end="1231">Pourquoi 2,0 mm est la norme pour les équipements actifs</h3>
<p data-start="1233" data-end="1319">L'enveloppe de 2,0 mm est la <strong data-start="1257" data-end="1283">point d'équilibre de l'industrie</strong> entre flexibilité et protection.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1321" data-end="1555">
<thead data-start="1321" data-end="1364">
<tr data-start="1321" data-end="1364">
<th class="" data-start="1321" data-end="1335" data-col-size="sm">Taille de la veste</th>
<th class="" data-start="1335" data-end="1364" data-col-size="md">Comportement dans les réseaux réels</th>
</tr>
</thead>
<tbody data-start="1407" data-end="1555">
<tr data-start="1407" data-end="1448">
<td data-start="1407" data-end="1415" data-col-size="sm">0,9 mm</td>
<td data-start="1415" data-end="1448" data-col-size="md">Trop fragile pour le live patching</td>
</tr>
<tr data-start="1449" data-end="1512">
<td data-start="1449" data-end="1461" data-col-size="sm"><strong data-start="1451" data-end="1460">2,0 mm</strong></td>
<td data-col-size="md" data-start="1461" data-end="1512"><strong data-start="1463" data-end="1510">Parfait pour les commutateurs, les panneaux et les émetteurs-récepteurs</strong></td>
</tr>
<tr data-start="1513" data-end="1555">
<td data-start="1513" data-end="1521" data-col-size="sm">3,0 mm</td>
<td data-col-size="md" data-start="1521" data-end="1555">Surdimensionné pour les ports de rack</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1557" data-end="1664">Il se plie facilement derrière les adaptateurs LC tout en protégeant la fibre des micro-courbures et des contraintes de manipulation.</p>
<hr data-start="1666" data-end="1669" />
<h3 data-start="1671" data-end="1696">Performances optiques</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1698" data-end="1945">
<thead data-start="1698" data-end="1727">
<tr data-start="1698" data-end="1727">
<th class="" data-start="1698" data-end="1710" data-col-size="sm">Paramètres</th>
<th class="" data-start="1710" data-end="1727" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1757" data-end="1945">
<tr data-start="1757" data-end="1794">
<td data-start="1757" data-end="1770" data-col-size="sm">Type de fibre</td>
<td data-start="1770" data-end="1794" data-col-size="sm">monomode 9/125 µm</td>
</tr>
<tr data-start="1795" data-end="1813">
<td data-start="1795" data-end="1806" data-col-size="sm">Face d'extrémité</td>
<td data-start="1806" data-end="1813" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1814" data-end="1844">
<td data-start="1814" data-end="1831" data-col-size="sm">Perte d'insertion</td>
<td data-start="1831" data-end="1844" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1845" data-end="1870">
<td data-start="1845" data-end="1859" data-col-size="sm">Perte de retour</td>
<td data-start="1859" data-end="1870" data-col-size="sm">≥ 50 dB</td>
</tr>
<tr data-start="1871" data-end="1913">
<td data-start="1871" data-end="1895" data-col-size="sm">Longueurs d'onde de fonctionnement</td>
<td data-start="1895" data-end="1913" data-col-size="sm">1310 / 1550 nm</td>
</tr>
<tr data-start="1914" data-end="1945">
<td data-start="1914" data-end="1927" data-col-size="sm">Durabilité</td>
<td data-start="1927" data-end="1945" data-col-size="sm">≥ 1000 accouplements</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1947" data-end="2037">Ces valeurs soutiennent <strong data-start="1968" data-end="2011">Ethernet, SDH, DWDM et réseaux d'accès</strong> avec une stabilité à long terme.</p>
<hr data-start="2039" data-end="2042" />
<h3 data-start="2044" data-end="2082">Ingénierie à l'intérieur du connecteur</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2084" data-end="2348">
<thead data-start="2084" data-end="2099">
<tr data-start="2084" data-end="2099">
<th class="" data-start="2084" data-end="2091" data-col-size="sm">Partie</th>
<th class="" data-start="2091" data-end="2099" data-col-size="sm">Rôle</th>
</tr>
</thead>
<tbody data-start="2116" data-end="2348">
<tr data-start="2116" data-end="2180">
<td data-start="2116" data-end="2142" data-col-size="sm">virole en zircone de 1,25 mm</td>
<td data-start="2142" data-end="2180" data-col-size="sm">Maintient le cœur de la fibre parfaitement aligné</td>
</tr>
<tr data-start="2181" data-end="2234">
<td data-start="2181" data-end="2204" data-col-size="sm">Polissage UPC de précision</td>
<td data-col-size="sm" data-start="2204" data-end="2234">Réduit la réflexion de Fresnel</td>
</tr>
<tr data-start="2235" data-end="2284">
<td data-start="2235" data-end="2253" data-col-size="sm">Loquet LC duplex</td>
<td data-start="2253" data-end="2284" data-col-size="sm">Maintien de l'orientation Tx/Rx</td>
</tr>
<tr data-start="2285" data-end="2348">
<td data-start="2285" data-end="2312" data-col-size="sm">Embout de décharge de traction de 2,0 mm</td>
<td data-col-size="sm" data-start="2312" data-end="2348">Prévient les dommages dus à la flexion et à la traction</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2350" data-end="2353" />
<h3 data-start="2355" data-end="2377">Questions et réponses professionnelles</h3>
<p data-start="2379" data-end="2562"><strong data-start="2379" data-end="2445">Le duplex UPC LC peut-il être utilisé pour des liaisons monomodes longue distance ?</strong><br data-start="2445" data-end="2448" />Oui, il est largement utilisé dans <strong data-start="2474" data-end="2515">liaisons dorsales, métropolitaines et avec les centres de données</strong> lorsqu'une faible perte et un accouplement stable sont requis.</p>
<p data-start="2564" data-end="2714"><strong data-start="2564" data-end="2604">L'UPC est-il compatible avec les adaptateurs APC ?</strong><br data-start="2604" data-end="2607" />Non. L'UPC ne doit être connecté qu'à l'UPC. Le mélange de l'UPC et de l'APC endommagera les embouts et dégradera les performances.</p>
<p data-start="2716" data-end="2886"><strong data-start="2716" data-end="2772">Pourquoi le duplex est-il préféré à deux connecteurs simplex ?</strong><br data-start="2772" data-end="2775" />Le recto-verso assure <strong data-start="2790" data-end="2860">polarité correcte, installation plus rapide et gestion plus propre des câbles</strong> dans les réseaux professionnels.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-monomode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC APC 3.0mm Duplex Singlemode Fiber Optic Connector</title>
		<link>https://www.fenxifiber.com/fr/product/lc-apc-3-0mm-duplex-monomode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-apc-3-0mm-duplex-monomode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:56:27 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=875</guid>

					<description><![CDATA[<p data-start="94" data-end="426">Les liaisons monomodes longue distance ne sont pas seulement synonymes de faibles pertes, elles sont aussi synonymes de <strong data-start="171" data-end="194">survie mécanique</strong>.<br data-start="195" data-end="198" />Dans les salles de backbone, les cadres ODF, les armoires extérieures et les conduits de couloir, les cavaliers de fibre sont pliés, tirés et réacheminés encore et encore.<br data-start="328" data-end="331" />Le <strong data-start="335" data-end="379">Connecteur LC APC 3.0mm Duplex Singlemode</strong> est conçu pour ce type d'environnement.</p>
<p data-start="428" data-end="633">Il combine <strong data-start="440" data-end="464">Polissage angulaire APC</strong> pour la stabilité optique avec un <strong data-start="494" data-end="521">Gaine résistante de 3,0 mm</strong> qui protège la fibre contre les <strong data-start="554" data-end="593">la tension, l'écrasement et la microflexion</strong>, même dans des conditions d'installation difficiles.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="640" data-end="717">Gaine de 3,0 mm - lorsque le câble lui-même fait partie de la fiabilité du système</h3>
<p data-start="719" data-end="903">Un cavalier double de 3,0 mm n'est pas simplement “plus épais”.<br data-start="765" data-end="768" />Il utilise un <strong data-start="778" data-end="843">couche de fil aramide plus résistante, tampon plus grand et botte renforcée</strong>, ce qui augmente considérablement sa marge de sécurité mécanique.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="905" data-end="1092">
<thead data-start="905" data-end="941">
<tr data-start="905" data-end="941">
<th class="" data-start="905" data-end="919" data-col-size="sm">Taille de la veste</th>
<th class="" data-start="919" data-end="941" data-col-size="md">Signification dans le monde réel</th>
</tr>
</thead>
<tbody data-start="976" data-end="1092">
<tr data-start="976" data-end="1021">
<td data-start="976" data-end="984" data-col-size="sm">2,0 mm</td>
<td data-col-size="md" data-start="984" data-end="1021">Pour les ports de rack à rack et les ports de périphériques</td>
</tr>
<tr data-start="1022" data-end="1092">
<td data-start="1022" data-end="1034" data-col-size="sm"><strong data-start="1024" data-end="1033">3,0 mm</strong></td>
<td data-col-size="md" data-start="1034" data-end="1092"><strong data-start="1036" data-end="1090">Pour le routage de la dorsale, les conduits au sol, les cavaliers d'armoire</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1094" data-end="1219">L'APC LC duplex de 3,0 mm est donc particulièrement adapté aux applications suivantes <strong data-start="1153" data-end="1218">salles de fibres métropolitaines, nœuds CATV et répartiteurs de télécommunications</strong>.</p>
<hr data-start="1221" data-end="1224" />
<h3 data-start="1226" data-end="1276">Géométrie APC pour les systèmes à réflexion critique</h3>
<p data-start="1278" data-end="1363">Le contact physique angulaire empêche la lumière réfléchie de pénétrer à nouveau dans le cœur de la fibre.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1365" data-end="1639">
<thead data-start="1365" data-end="1404">
<tr data-start="1365" data-end="1404">
<th class="" data-start="1365" data-end="1387" data-col-size="sm">Performances optiques</th>
<th class="" data-start="1387" data-end="1404" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1443" data-end="1639">
<tr data-start="1443" data-end="1480">
<td data-start="1443" data-end="1456" data-col-size="sm">Type de fibre</td>
<td data-start="1456" data-end="1480" data-col-size="sm">monomode 9/125 µm</td>
</tr>
<tr data-start="1481" data-end="1502">
<td data-start="1481" data-end="1490" data-col-size="sm">Polonais</td>
<td data-start="1490" data-end="1502" data-col-size="sm">APC (8°)</td>
</tr>
<tr data-start="1503" data-end="1533">
<td data-start="1503" data-end="1520" data-col-size="sm">Perte d'insertion</td>
<td data-start="1520" data-end="1533" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1534" data-end="1559">
<td data-start="1534" data-end="1548" data-col-size="sm">Perte de retour</td>
<td data-col-size="sm" data-start="1548" data-end="1559">≥ 60 dB</td>
</tr>
<tr data-start="1560" data-end="1607">
<td data-start="1560" data-end="1582" data-col-size="sm">Longueurs d'onde de travail</td>
<td data-col-size="sm" data-start="1582" data-end="1607">1310 / 1490 / 1550 nm</td>
</tr>
<tr data-start="1608" data-end="1639">
<td data-start="1608" data-end="1621" data-col-size="sm">Durabilité</td>
<td data-col-size="sm" data-start="1621" data-end="1639">≥ 1000 accouplements</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1641" data-end="1736">Ce contrôle de la réflexion est essentiel pour <strong data-start="1682" data-end="1735">RFoG, superposition CATV, GPON et liaisons DWDM longue distance</strong>.</p>
<hr data-start="1738" data-end="1741" />
<h3 data-start="1743" data-end="1801">Structure duplex pour une véritable transmission bidirectionnelle</h3>
<p data-start="1803" data-end="1882">Le format LC duplex verrouille deux fibres ensemble dans un corps de connecteur, ce qui garantit :</p>
<ul data-start="1884" data-end="1968">
<li data-start="1884" data-end="1910">
<p data-start="1886" data-end="1910">Alignement stable Tx/Rx</p>
</li>
<li data-start="1911" data-end="1934">
<p data-start="1913" data-end="1934">Une installation plus rapide</p>
</li>
<li data-start="1935" data-end="1968">
<p data-start="1937" data-end="1968">Risque réduit d'erreurs de polarité</p>
</li>
</ul>
<p data-start="1970" data-end="2092">Même lorsque les câbles sont fortement acheminés par des chemins de câbles, <strong data-start="2027" data-end="2091">duplex APC LC protège et synchronise les deux canaux</strong>.</p>
<hr data-start="2094" data-end="2097" />
<h3 data-start="2099" data-end="2124">Détails techniques</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2126" data-end="2399">
<thead data-start="2126" data-end="2150">
<tr data-start="2126" data-end="2150">
<th class="" data-start="2126" data-end="2138" data-col-size="sm">Composant</th>
<th class="" data-start="2138" data-end="2150" data-col-size="sm">Fonction</th>
</tr>
</thead>
<tbody data-start="2174" data-end="2399">
<tr data-start="2174" data-end="2234">
<td data-start="2174" data-end="2204" data-col-size="sm">Virole APC en zircone de 1,25 mm</td>
<td data-col-size="sm" data-start="2204" data-end="2234">Maintient un angle précis de 8°.</td>
</tr>
<tr data-start="2235" data-end="2290">
<td data-start="2235" data-end="2260" data-col-size="sm">Clip duplex renforcé</td>
<td data-col-size="sm" data-start="2260" data-end="2290">Maintient les deux fibres en toute sécurité</td>
</tr>
<tr data-start="2291" data-end="2337">
<td data-start="2291" data-end="2312" data-col-size="sm">Gaine épaisse de 3,0 mm</td>
<td data-col-size="sm" data-start="2312" data-end="2337">Absorbe la force de traction</td>
</tr>
<tr data-start="2338" data-end="2399">
<td data-start="2338" data-end="2361" data-col-size="sm">Polissage APC longue durée</td>
<td data-col-size="sm" data-start="2361" data-end="2399">Maintient la perte de retour stable dans le temps</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2401" data-end="2404" />
<h3 data-start="2406" data-end="2428">Questions et réponses professionnelles</h3>
<p data-start="2430" data-end="2574"><strong data-start="2430" data-end="2469">L'épaisseur de 3,0 mm est-elle trop importante pour les adaptateurs LC ?</strong><br data-start="2469" data-end="2472" />Non. Seul le câble est plus épais. La virole et le boîtier LC restent standard et s'adaptent à tous les adaptateurs LC APC.</p>
<p data-start="2576" data-end="2733"><strong data-start="2576" data-end="2624">Quand dois-je choisir 3,0 mm au lieu de 2,0 mm ?</strong><br data-start="2624" data-end="2627" />Lorsque les cordons de raccordement sont <strong data-start="2648" data-end="2699">acheminés dans des gaines, des armoires ou des plateaux partagés</strong> où ils peuvent être pliés ou tirés.</p>
<p data-start="2735" data-end="2914"><strong data-start="2735" data-end="2781">L'APC a-t-il vraiment de l'importance pour les liens dorsaux ?</strong><br data-start="2781" data-end="2784" />Oui, sur de longs trajets monomodes avec des séparateurs, des amplificateurs ou des signaux RF, <strong data-start="2857" data-end="2891">les réflexions s'accumulent rapidement</strong> et APC l'empêche.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-apc-3-0mm-duplex-monomode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC APC 2.0mm Duplex Singlemode</title>
		<link>https://www.fenxifiber.com/fr/product/lc-apc-2-0mm-duplex-monomode/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-apc-2-0mm-duplex-monomode/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:55:05 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=873</guid>

					<description><![CDATA[<p data-start="99" data-end="420">Dans les réseaux PON et les réseaux monomodes longue distance, le plus grand ennemi caché n'est pas la perte - c'est <strong data-start="191" data-end="205">réflexion</strong>.<br data-start="206" data-end="209" />Chaque signal réfléchi crée un bruit qui interfère avec les lasers en amont, en particulier dans les cas suivants <strong data-start="298" data-end="340">Systèmes GPON, XG-PON et RF sur fibre</strong>.<br data-start="341" data-end="344" />C'est précisément la raison pour laquelle la <strong data-start="368" data-end="412">Connecteur LC APC 2.0mm Duplex Singlemode</strong> existent.</p>
<p data-start="422" data-end="724">En utilisant un <strong data-start="434" data-end="476">Contact physique angulaire à 8 degrés (APC)</strong> sur les deux embouts LC, ce connecteur duplex repousse la lumière réfléchie hors du cœur de la fibre au lieu de la renvoyer vers l'émetteur. Il en résulte une <strong data-start="628" data-end="660">canal optique beaucoup plus propre</strong>, même en présence de plusieurs splitters et de longs parcours de fibres.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="731" data-end="777">APC duplex pour une véritable transmission bidirectionnelle</h3>
<p data-start="779" data-end="893">Contrairement aux cavaliers simplex, les connecteurs LC duplex conservent les caractéristiques suivantes <strong data-start="829" data-end="868">Fibres Tx et Rx appariées en permanence</strong>, qui est essentiel pour :</p>
<ul data-start="895" data-end="988">
<li data-start="895" data-end="920">
<p data-start="897" data-end="920">OLT <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Connexions ONU</p>
</li>
<li data-start="921" data-end="953">
<p data-start="923" data-end="953">Liaisons dorsales entre les baies</p>
</li>
<li data-start="954" data-end="988">
<p data-start="956" data-end="988">Ports d'équipements optiques actifs</p>
</li>
</ul>
<p data-start="990" data-end="1088">Dans les panneaux à haute densité, les cavaliers APC duplex permettent également de réduire les erreurs de polarité et d'accélérer la maintenance.</p>
<hr data-start="1090" data-end="1093" />
<h3 data-start="1095" data-end="1141">2,0 mm - la bonne taille pour les réseaux en direct</h3>
<p data-start="1143" data-end="1435">Un cavalier PON ou backbone est constamment manipulé.<br data-start="1196" data-end="1199" />Il est branché sur les cartes OLT, acheminé par des gestionnaires de câbles et parfois retiré pour les tests.<br data-start="1294" data-end="1297" />C'est pourquoi ce modèle utilise un <strong data-start="1327" data-end="1374">Gaine de 2,0 mm au lieu de la fibre pigtail de 0,9 mm</strong> - il prévoit <strong data-start="1389" data-end="1434">une réelle réduction de la tension sans devenir rigide</strong>.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1437" data-end="1632">
<thead data-start="1437" data-end="1473">
<tr data-start="1437" data-end="1473">
<th class="" data-start="1437" data-end="1450" data-col-size="sm">Taille du câble</th>
<th class="" data-start="1450" data-end="1473" data-col-size="sm">Ce qu'il faut faire</th>
</tr>
</thead>
<tbody data-start="1508" data-end="1632">
<tr data-start="1508" data-end="1541">
<td data-start="1508" data-end="1516" data-col-size="sm">0,9 mm</td>
<td data-start="1516" data-end="1541" data-col-size="sm">Raccordement à l'intérieur des plateaux</td>
</tr>
<tr data-start="1542" data-end="1593">
<td data-start="1542" data-end="1554" data-col-size="sm"><strong data-start="1544" data-end="1553">2,0 mm</strong></td>
<td data-start="1554" data-end="1593" data-col-size="sm"><strong data-start="1556" data-end="1591">Patching en direct et ports d'équipement</strong></td>
</tr>
<tr data-start="1594" data-end="1632">
<td data-start="1594" data-end="1602" data-col-size="sm">3,0 mm</td>
<td data-start="1602" data-end="1632" data-col-size="sm">Liens extérieurs et à usage intensif</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1634" data-end="1637" />
<h3 data-start="1639" data-end="1687">Comportement optique requis par les réseaux PON</h3>
<p data-start="1689" data-end="1766">Le polissage APC améliore considérablement les performances de réflexion par rapport à l'UPC.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1768" data-end="2050">
<thead data-start="1768" data-end="1810">
<tr data-start="1768" data-end="1810">
<th class="" data-start="1768" data-end="1793" data-col-size="sm">Caractéristiques optiques</th>
<th class="" data-start="1793" data-end="1810" data-col-size="sm">Niveau typique</th>
</tr>
</thead>
<tbody data-start="1853" data-end="2050">
<tr data-start="1853" data-end="1885">
<td data-start="1853" data-end="1861" data-col-size="sm">Fibre</td>
<td data-start="1861" data-end="1885" data-col-size="sm">monomode 9/125 µm</td>
</tr>
<tr data-start="1886" data-end="1916">
<td data-start="1886" data-end="1897" data-col-size="sm">Face d'extrémité</td>
<td data-start="1897" data-end="1916" data-col-size="sm">APC (coudé à 8°)</td>
</tr>
<tr data-start="1917" data-end="1947">
<td data-start="1917" data-end="1934" data-col-size="sm">Perte d'insertion</td>
<td data-start="1934" data-end="1947" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1948" data-end="1973">
<td data-start="1948" data-end="1962" data-col-size="sm">Perte de retour</td>
<td data-start="1962" data-end="1973" data-col-size="sm">≥ 60 dB</td>
</tr>
<tr data-start="1974" data-end="2023">
<td data-start="1974" data-end="1998" data-col-size="sm">Longueurs d'onde de fonctionnement</td>
<td data-start="1998" data-end="2023" data-col-size="sm">1310 / 1490 / 1550 nm</td>
</tr>
<tr data-start="2024" data-end="2050">
<td data-start="2024" data-end="2040" data-col-size="sm">Cycles d'accouplement</td>
<td data-start="2040" data-end="2050" data-col-size="sm">≥ 1000</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2052" data-end="2154">Ce niveau de retour sur perte est essentiel pour <strong data-start="2091" data-end="2153">GPON, XG-PON, CATV overlay et liaisons monomodes longue distance</strong>.</p>
<hr data-start="2156" data-end="2159" />
<h3 data-start="2161" data-end="2200">Conçu pour les cadres de télécommunications denses</h3>
<p data-start="2202" data-end="2354">Même avec la géométrie APC, le connecteur utilise toujours la fonction <strong data-start="2255" data-end="2276">format LC compact</strong>, permettant <strong data-start="2287" data-end="2313">deux fois la densité des ports</strong> de connecteurs SC dans le même espace de rack.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2356" data-end="2672">
<thead data-start="2356" data-end="2394">
<tr data-start="2356" data-end="2394">
<th class="" data-start="2356" data-end="2378" data-col-size="sm">Détail de la construction</th>
<th class="" data-start="2378" data-end="2394" data-col-size="sm">Ce qu'il fait</th>
</tr>
</thead>
<tbody data-start="2432" data-end="2672">
<tr data-start="2432" data-end="2492">
<td data-start="2432" data-end="2450" data-col-size="sm">Loquet LC duplex</td>
<td data-start="2450" data-end="2492" data-col-size="sm">Bloque les deux fibres dans un alignement correct</td>
</tr>
<tr data-start="2493" data-end="2550">
<td data-start="2493" data-end="2519" data-col-size="sm">Embouts en céramique de 1,25 mm</td>
<td data-start="2519" data-end="2550" data-col-size="sm">Maintenir la précision de l'angle de l'APC</td>
</tr>
<tr data-start="2551" data-end="2607">
<td data-start="2551" data-end="2576" data-col-size="sm">Bottes renforcées de 2,0 mm</td>
<td data-start="2576" data-end="2607" data-col-size="sm">Prévenir la micro-flexion des fibres</td>
</tr>
<tr data-start="2608" data-end="2672">
<td data-start="2608" data-end="2634" data-col-size="sm">Polissage APC de précision</td>
<td data-start="2634" data-end="2672" data-col-size="sm">Empêche les reflets de pénétrer dans le laser</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2674" data-end="2677" />
<h3 data-start="2679" data-end="2701">Questions et réponses professionnelles</h3>
<p data-start="2703" data-end="2871"><strong data-start="2703" data-end="2743">L'APC LC peut-elle être connectée en duplex à l'UPC LC ?</strong><br data-start="2743" data-end="2746" />Non. Les connecteurs APC et UPC ne doivent jamais être accouplés. La face frontale angulaire de l'APC serait endommagée et la réflexion augmenterait fortement.</p>
<p data-start="2873" data-end="3012"><strong data-start="2873" data-end="2905">Le duplex est-il nécessaire pour le PON ?</strong><br data-start="2905" data-end="2908" />Oui. Les ports OLT et ONU nécessitent <strong data-start="2939" data-end="2963">transmission bidirectionnelle</strong>, et le duplex LC permet d'appairer correctement le Tx et le Rx.</p>
<p data-start="3014" data-end="3227"><strong data-start="3014" data-end="3056">Pourquoi ne pas utiliser 3,0 mm pour les cordons de raccordement PON ?</strong><br data-start="3056" data-end="3059" />3.0mm est utilisé lorsque les câbles sont exposés à des tractions importantes. Pour les <strong data-start="3119" data-end="3159">baies, étagères OLT et cadres intérieurs</strong>, 2,0 mm offre le meilleur équilibre entre <strong data-start="3196" data-end="3226">flexibilité et protection</strong>.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-apc-2-0mm-duplex-monomode/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Connecteur multimode duplex LC UPC 3.0mm (Rose-Rouge)</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-rose-rouge/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-rose-rouge/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:53:50 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=871</guid>

					<description><![CDATA[<p data-start="235" data-end="521">Dans les rangées des centres de données et les racks industriels, les cavaliers de fibre ne sont pas traités avec délicatesse.<br data-start="319" data-end="322" />Ils sont tirés, pliés autour des gestionnaires de câbles, débranchés pour des mises à jour, puis rebranchés.<br data-start="417" data-end="420" />C'est exactement là que le <strong data-start="446" data-end="490">LC UPC 3.0mm Duplex Multimode (Rose-Rouge)</strong> est conçu pour fonctionner.</p>
<p data-start="523" data-end="776">Au lieu d'une fine veste de bureau, ce modèle utilise une veste à manches longues. <strong data-start="580" data-end="630">câble complet de 3,0 mm avec longues gaines de décharge de traction</strong>, La fibre est ainsi protégée physiquement pour survivre aux environnements à fort trafic, sans créer de micro-courbures qui dégradent la qualité du signal.</p>
<p data-start="778" data-end="956">Dans le même temps, le <strong data-start="800" data-end="820">Format LC duplex</strong> maintient les fibres de transmission et de réception verrouillées ensemble, en conservant une polarité correcte et en réduisant les erreurs d'installation dans les panneaux de raccordement denses.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="963" data-end="1009">Ce que signifie le logement rose-rouge</h3>
<p data-start="1011" data-end="1245">Dans le câblage optique moderne, la couleur n'est plus une décoration, c'est un outil de travail.<br data-start="1091" data-end="1094" />Le <strong data-start="1098" data-end="1115">corps rose-rouge</strong> identifie ce connecteur comme étant destiné à <strong data-start="1164" data-end="1198">fibre multimode à large bande passante</strong>, typiquement <strong data-start="1210" data-end="1224">OM4 ou OM5</strong>, qui sont utilisés pour :</p>
<ul data-start="1247" data-end="1343">
<li data-start="1247" data-end="1272">
<p data-start="1249" data-end="1272">Ethernet 40G et 100G</p>
</li>
<li data-start="1273" data-end="1312">
<p data-start="1275" data-end="1312">Réseaux SAN et de stockage à grande vitesse</p>
</li>
<li data-start="1313" data-end="1343">
<p data-start="1315" data-end="1343">Liaisons dorsales des centres de données</p>
</li>
</ul>
<p data-start="1345" data-end="1473">Les techniciens peuvent immédiatement reconnaître ces cavaliers dans les racks mixtes qui contiennent également des câbles aqua (OM3) et jaunes (monomode).</p>
<hr data-start="1475" data-end="1478" />
<h3 data-start="1480" data-end="1518">Un comportement optique sur lequel vous pouvez compter</h3>
<p data-start="1520" data-end="1814">Même avec la lourde gaine de 3,0 mm, le connecteur utilise toujours un connecteur de type <strong data-start="1581" data-end="1626">virole de précision en céramique de zircone de 1,25 mm</strong> et un <strong data-start="1633" data-end="1658">Face d'extrémité polie UPC</strong>.<br data-start="1659" data-end="1662" />Cette combinaison permet <strong data-start="1688" data-end="1715">contact physique stable</strong> entre les fibres, ce qui est essentiel pour les liaisons multimodes à courte portée fonctionnant à des débits de données très élevés.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1816" data-end="2087">
<thead data-start="1816" data-end="1852">
<tr data-start="1816" data-end="1852">
<th class="" data-start="1816" data-end="1835" data-col-size="sm">Point de performance</th>
<th class="" data-start="1835" data-end="1852" data-col-size="sm">Niveau typique</th>
</tr>
</thead>
<tbody data-start="1890" data-end="2087">
<tr data-start="1890" data-end="1934">
<td data-start="1890" data-end="1903" data-col-size="sm">Type de fibre</td>
<td data-start="1903" data-end="1934" data-col-size="sm">OM3 / OM4 / OM5 (50/125 µm)</td>
</tr>
<tr data-start="1935" data-end="1951">
<td data-start="1935" data-end="1944" data-col-size="sm">Polonais</td>
<td data-start="1944" data-end="1951" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1952" data-end="1982">
<td data-start="1952" data-end="1969" data-col-size="sm">Perte d'insertion</td>
<td data-start="1969" data-end="1982" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1983" data-end="2008">
<td data-start="1983" data-end="1997" data-col-size="sm">Perte de retour</td>
<td data-start="1997" data-end="2008" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="2009" data-end="2050">
<td data-start="2009" data-end="2031" data-col-size="sm">Longueurs d'onde de travail</td>
<td data-start="2031" data-end="2050" data-col-size="sm">850 nm, 1300 nm</td>
</tr>
<tr data-start="2051" data-end="2087">
<td data-start="2051" data-end="2070" data-col-size="sm">Durée de vie de la prise et de la déconnexion</td>
<td data-start="2070" data-end="2087" data-col-size="sm">≥ 1000 cycles</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2089" data-end="2179">Ces valeurs sont bien en deçà des limites requises pour <strong data-start="2142" data-end="2178">Optique SR 10G, 25G, 40G et 100G</strong>.</p>
<hr data-start="2181" data-end="2184" />
<h3 data-start="2186" data-end="2233">Construit comme un cavalier de terrain et non comme un cordon de laboratoire</h3>
<p data-start="2235" data-end="2328">Alors qu'un câble duplex de 2,0 mm met l'accent sur la flexibilité, le câble duplex de 2,0 mm met l'accent sur la flexibilité. <strong data-start="2290" data-end="2327">La version 3.0mm met l'accent sur la survie</strong>.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2330" data-end="2653">
<thead data-start="2330" data-end="2369">
<tr data-start="2330" data-end="2369">
<th class="" data-start="2330" data-end="2353" data-col-size="sm">Élément de construction</th>
<th class="" data-start="2353" data-end="2369" data-col-size="md">Ce qu'il fait</th>
</tr>
</thead>
<tbody data-start="2408" data-end="2653">
<tr data-start="2408" data-end="2461">
<td data-start="2408" data-end="2429" data-col-size="sm">Gaine extérieure de 3,0 mm</td>
<td data-col-size="md" data-start="2429" data-end="2461">Résiste à l'écrasement et à l'arrachement</td>
</tr>
<tr data-start="2462" data-end="2527">
<td data-start="2462" data-end="2482" data-col-size="sm">Longues bottes doubles</td>
<td data-start="2482" data-end="2527" data-col-size="md">Absorber le stress avant qu'il n'atteigne la fibre</td>
</tr>
<tr data-start="2528" data-end="2594">
<td data-start="2528" data-end="2549" data-col-size="sm">Loquet LC push-pull</td>
<td data-start="2549" data-end="2594" data-col-size="md">Maintient les connecteurs en place dans les panneaux encombrés</td>
</tr>
<tr data-start="2595" data-end="2653">
<td data-start="2595" data-end="2614" data-col-size="sm">Embouts en céramique</td>
<td data-start="2614" data-end="2653" data-col-size="md">Maintenir un alignement stable dans le temps</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2655" data-end="2819">Le connecteur est donc particulièrement adapté pour <strong data-start="2704" data-end="2781">baies centrales, armoires d'agrégation, armoires industrielles et salles de télécommunications</strong>, où les câbles sont fréquemment manipulés.</p>
<hr data-start="2821" data-end="2824" />
<h3 data-start="2826" data-end="2848">Questions et réponses professionnelles</h3>
<p data-start="2850" data-end="3038"><strong data-start="2850" data-end="2894">Peut-on le mélanger avec des cavaliers aqua OM3 ?</strong><br data-start="2894" data-end="2897" />Oui, le connecteur est entièrement compatible avec les fibres multimodes OM3, OM4 et OM5. La couleur rose-rouge indique simplement <strong data-start="3011" data-end="3037">multimode de qualité supérieure</strong>.</p>
<p data-start="3040" data-end="3244"><strong data-start="3040" data-end="3078">3,0 mm est-il vraiment nécessaire à l'intérieur ?</strong><br data-start="3078" data-end="3081" />Dans les baies silencieuses, 2,0 mm suffisent. Dans les <strong data-start="3115" data-end="3179">les rangées de centres de données occupées, les armoires industrielles ou les cadres de télécommunication</strong>, L'utilisation d'un câble de 3,0 mm réduit considérablement les dommages causés au câble et l'instabilité du signal.</p>
<p data-start="3246" data-end="3415"><strong data-start="3246" data-end="3297">L'UPC LC peut-il être utilisé avec des câbles de dérivation MPO-LC ?</strong><br data-start="3297" data-end="3300" />Oui. Ce connecteur est couramment utilisé à l'extrémité LC de <strong data-start="3354" data-end="3383">Assemblages en éventail MPO-LC</strong> pour les liaisons multimodes à grande vitesse.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-3-0mm-duplex-multimode-rose-rouge/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Connecteur multimode duplex LC UPC 2.0mm (Rose-Rouge)</title>
		<link>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-rose-rouge/</link>
					<comments>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-rose-rouge/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubdate>Wed, 04 Feb 2026 02:52:43 +0000</pubdate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=868</guid>

					<description><![CDATA[<h3 data-start="80" data-end="122">Des liaisons à grande vitesse clairement identifiées</h3>
<p data-start="124" data-end="488">Le <strong data-start="128" data-end="172">LC UPC 2.0mm Duplex Multimode (Rose-Rouge)</strong> est conçu pour <strong data-start="196" data-end="258">des centres de données et des réseaux d'entreprise modernes et à large bande passante</strong>.<br data-start="259" data-end="262" />Son <strong data-start="266" data-end="286">conception LC duplex</strong> porte <strong data-start="295" data-end="338">Fibres Tx/Rx dans un seul verrou compact</strong>, tandis que le <strong data-start="350" data-end="370">boîtier rose-rouge</strong> signale instantanément <strong data-start="389" data-end="425">multimode de haute qualité (OM4 / OM5)</strong>-Parfait pour les rayonnages où le codage couleur permet d'éviter des erreurs coûteuses.</p>
<p data-start="490" data-end="698">Avec <strong data-start="495" data-end="536">Embouts céramiques de 1,25 mm polis UPC</strong> et un <strong data-start="543" data-end="568">gaine durable de 2,0 mm</strong>, ce connecteur fournit <strong data-start="594" data-end="624">performance optique stable</strong> et <strong data-start="629" data-end="659">fiabilité des correctifs quotidiens</strong> pour <strong data-start="664" data-end="697">Liaisons courtes 10G à 100G</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="705" data-end="752">Pourquoi le duplex LC est la norme pour les centres de données</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="754" data-end="948">
<thead data-start="754" data-end="808">
<tr data-start="754" data-end="808">
<th class="" data-start="754" data-end="771" data-col-size="sm">Type de connecteur</th>
<th class="" data-start="771" data-end="789" data-col-size="sm">Ce qu'il contient</th>
<th class="" data-start="789" data-end="808" data-col-size="sm">Où il est utilisé</th>
</tr>
</thead>
<tbody data-start="823" data-end="948">
<tr data-start="823" data-end="866">
<td data-start="823" data-end="833" data-col-size="sm">Simplex</td>
<td data-start="833" data-end="845" data-col-size="sm">Une fibre</td>
<td data-start="845" data-end="866" data-col-size="sm">Queues de cochon, tests</td>
</tr>
<tr data-start="867" data-end="948">
<td data-start="867" data-end="883" data-col-size="sm"><strong data-start="869" data-end="882">Duplex LC</strong></td>
<td data-start="883" data-end="908" data-col-size="sm"><strong data-start="885" data-end="907">Deux fibres (Tx/Rx)</strong></td>
<td data-start="908" data-end="948" data-col-size="sm"><strong data-start="910" data-end="946">Interrupteur <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Serveur, commutateur <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Interrupteur</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="950" data-end="1047">Une seule prise duplex remplace deux cordons simplex.<strong data-start="998" data-end="1046">des installations plus rapides, moins d'erreurs, des baies plus propres</strong>.</p>
<hr data-start="1049" data-end="1052" />
<h3 data-start="1054" data-end="1095">Rose-rouge = multimode à large bande passante</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1097" data-end="1280">
<thead data-start="1097" data-end="1143">
<tr data-start="1097" data-end="1143">
<th class="" data-start="1097" data-end="1111" data-col-size="sm">Qualité de la fibre</th>
<th class="" data-start="1111" data-end="1119" data-col-size="sm">Couleur</th>
<th class="" data-start="1119" data-end="1143" data-col-size="sm">Portée typique à 100G</th>
</tr>
</thead>
<tbody data-start="1158" data-end="1280">
<tr data-start="1158" data-end="1180">
<td data-start="1158" data-end="1164" data-col-size="sm">OM3</td>
<td data-start="1164" data-end="1171" data-col-size="sm">Aqua</td>
<td data-start="1171" data-end="1180" data-col-size="sm">~70 m</td>
</tr>
<tr data-start="1181" data-end="1229">
<td data-start="1181" data-end="1191" data-col-size="sm"><strong data-start="1183" data-end="1190">OM4</strong></td>
<td data-start="1191" data-end="1215" data-col-size="sm"><strong data-start="1193" data-end="1214">Rose-rouge / Violet</strong></td>
<td data-start="1215" data-end="1229" data-col-size="sm"><strong data-start="1217" data-end="1227">~100 m</strong></td>
</tr>
<tr data-start="1230" data-end="1280">
<td data-start="1230" data-end="1240" data-col-size="sm"><strong data-start="1232" data-end="1239">OM5</strong></td>
<td data-start="1240" data-end="1262" data-col-size="sm"><strong data-start="1242" data-end="1261">Rose-red / Lime</strong></td>
<td data-start="1262" data-end="1280" data-col-size="sm"><strong data-start="1264" data-end="1278">Prêt pour le SWDM</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1282" data-end="1387">L'utilisation de connecteurs rose-rouge aide les techniciens <strong data-start="1326" data-end="1358">repérer instantanément les trajets OM4/OM5</strong> dans les environnements à fibres mixtes.</p>
<hr data-start="1389" data-end="1392" />
<h3 data-start="1394" data-end="1429">Performance optique (multimode)</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1431" data-end="1701">
<thead data-start="1431" data-end="1460">
<tr data-start="1431" data-end="1460">
<th class="" data-start="1431" data-end="1443" data-col-size="sm">Paramètres</th>
<th class="" data-start="1443" data-end="1460" data-col-size="sm">Valeur typique</th>
</tr>
</thead>
<tbody data-start="1471" data-end="1701">
<tr data-start="1471" data-end="1515">
<td data-start="1471" data-end="1484" data-col-size="sm">Type de fibre</td>
<td data-start="1484" data-end="1515" data-col-size="sm">OM3 / OM4 / OM5 (50/125 µm)</td>
</tr>
<tr data-start="1516" data-end="1532">
<td data-start="1516" data-end="1525" data-col-size="sm">Polonais</td>
<td data-start="1525" data-end="1532" data-col-size="sm">CUP</td>
</tr>
<tr data-start="1533" data-end="1563">
<td data-start="1533" data-end="1550" data-col-size="sm">Perte d'insertion</td>
<td data-start="1550" data-end="1563" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1564" data-end="1589">
<td data-start="1564" data-end="1578" data-col-size="sm">Perte de retour</td>
<td data-start="1578" data-end="1589" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1590" data-end="1621">
<td data-start="1590" data-end="1604" data-col-size="sm">Longueurs d'onde</td>
<td data-start="1604" data-end="1621" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1622" data-end="1669">
<td data-start="1622" data-end="1641" data-col-size="sm">Vitesses prises en charge</td>
<td data-col-size="sm" data-start="1641" data-end="1669">10G, 25G, 40G, 100G (SR)</td>
</tr>
<tr data-start="1670" data-end="1701">
<td data-start="1670" data-end="1684" data-col-size="sm">La vie sexuelle</td>
<td data-start="1684" data-end="1701" data-col-size="sm">≥ 1000 cycles</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1703" data-end="1706" />
<h3 data-start="1708" data-end="1745">Détails mécaniques et de construction</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1747" data-end="2066">
<thead data-start="1747" data-end="1774">
<tr data-start="1747" data-end="1774">
<th class="" data-start="1747" data-end="1757" data-col-size="sm">Fonctionnalité</th>
<th class="" data-start="1757" data-end="1774" data-col-size="sm">Spécifications</th>
</tr>
</thead>
<tbody data-start="1785" data-end="2066">
<tr data-start="1785" data-end="1821">
<td data-start="1785" data-end="1804" data-col-size="sm">Format du connecteur</td>
<td data-start="1804" data-end="1821" data-col-size="sm"><strong data-start="1806" data-end="1819">LC Duplex</strong></td>
</tr>
<tr data-start="1822" data-end="1853">
<td data-start="1822" data-end="1839" data-col-size="sm">Diamètre du câble</td>
<td data-col-size="sm" data-start="1839" data-end="1853"><strong data-start="1841" data-end="1851">2,0 mm</strong></td>
</tr>
<tr data-start="1854" data-end="1892">
<td data-start="1854" data-end="1864" data-col-size="sm">Embout</td>
<td data-col-size="sm" data-start="1864" data-end="1892">Céramique zircone de 1,25 mm</td>
</tr>
<tr data-start="1893" data-end="1938">
<td data-start="1893" data-end="1909" data-col-size="sm">Couleur du boîtier</td>
<td data-start="1909" data-end="1938" data-col-size="sm"><strong data-start="1911" data-end="1923">Rose-Rouge</strong> (ID OM4/OM5)</td>
</tr>
<tr data-start="1939" data-end="1963">
<td data-start="1939" data-end="1947" data-col-size="sm">Loquet</td>
<td data-col-size="sm" data-start="1947" data-end="1963">LC push-pull</td>
</tr>
<tr data-start="1964" data-end="1997">
<td data-start="1964" data-end="1971" data-col-size="sm">Botte</td>
<td data-col-size="sm" data-start="1971" data-end="1997">Soulagement de la tension standard</td>
</tr>
<tr data-start="1998" data-end="2035">
<td data-start="1998" data-end="2015" data-col-size="sm">Température de fonctionnement</td>
<td data-start="2015" data-end="2035" data-col-size="sm">-40 °C à +75 °C</td>
</tr>
<tr data-start="2036" data-end="2066">
<td data-start="2036" data-end="2055" data-col-size="sm">Résistance à la traction</td>
<td data-start="2055" data-end="2066" data-col-size="sm">≥ 100 N</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2068" data-end="2190">Le <strong data-start="2072" data-end="2089">Gaine de 2,0 mm</strong> soldes <strong data-start="2099" data-end="2132">flexibilité et force de traction</strong>, idéal pour <strong data-start="2144" data-end="2180">rack-à-rack et dispositif-à-panneau</strong> les correctifs.</p>
<hr data-start="2192" data-end="2195" />
<h3 data-start="2197" data-end="2221">Où il s'adapte le mieux</h3>
<ul data-start="2223" data-end="2414">
<li data-start="2223" data-end="2261">
<p data-start="2225" data-end="2261">Liaisons de commutateur à commutateur dans les centres de données</p>
</li>
<li data-start="2262" data-end="2306">
<p data-start="2264" data-end="2306">Connexions de serveur et de stockage (optique SR)</p>
</li>
<li data-start="2307" data-end="2337">
<p data-start="2309" data-end="2337">Ensembles d'éclatement MPO-LC</p>
</li>
<li data-start="2338" data-end="2372">
<p data-start="2340" data-end="2372">Backbones LAN et SAN d'entreprise</p>
</li>
<li data-start="2373" data-end="2414">
<p data-start="2375" data-end="2414">Cavaliers de test et de contrôle multimode</p>
</li>
</ul>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/fr/product/lc-upc-2-0mm-duplex-multimode-rose-rouge/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>