{"id":1240,"date":"2026-10-15T04:19:00","date_gmt":"2026-10-15T04:19:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-package-types\/"},"modified":"2026-10-02T09:59:33","modified_gmt":"2026-10-02T09:59:33","slug":"plc-splitter-package-types","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/fr\/plc-splitter-package-types\/","title":{"rendered":"Types de bo\u00eetiers de r\u00e9partiteurs PLC : Mini ABS LGX nu et en rack"},"content":{"rendered":"<p><strong>Choose the PLC splitter package after the cabinet, closure or rack interface is fixed. The optical circuit may be similar across formats, but tube diameter, pigtail exit, connector presentation, mounting method and technician access determine whether the assembly can be installed and serviced.<\/strong><\/p>\n<p>Bare-fibre and steel-tube units suit protected internal integration; ABS modules add mechanical protection; LGX, cassette and rack formats provide connectorized presentation and mounting features. Package names are not universal dimensional standards, so procurement should request a controlled outline drawing and test a production-representative sample in the target enclosure.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats for enclosure and rack selection\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter package types?<\/h2>\n<p>Utilisez le tableau de d\u00e9cision pour traduire ce sujet en crit\u00e8res pr\u00e9cis r\u00e9gissant l'achat, la conception et la r\u00e9ception. Chaque ligne doit \u00eatre valid\u00e9e par rapport aux normes en vigueur concernant l'\u00e9quipement, l'itin\u00e9raire et la destination, plut\u00f4t que d'\u00eatre simplement copi\u00e9e \u00e0 partir d'un catalogue g\u00e9n\u00e9rique.<\/p>\n<table>\n<thead>\n<tr>\n<th>Domaine de d\u00e9cision<\/th>\n<th>\u00c9l\u00e9ments \u00e0 pr\u00e9ciser<\/th>\n<th>Pourquoi est-ce important ?<\/th>\n<th>\u00c9l\u00e9ments de preuve \u00e0 conserver<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Installation location<\/td>\n<td>Closure, wall box, cabinet or rack<\/td>\n<td>Defines protection and mounting needs<\/td>\n<td>Approved enclosure drawing<\/td>\n<\/tr>\n<tr>\n<td>Fibre presentation<\/td>\n<td>Bare fibre, pigtails or adapters<\/td>\n<td>Changes splicing and patching work<\/td>\n<td>Port and tail schedule<\/td>\n<\/tr>\n<tr>\n<td>Mechanical envelope<\/td>\n<td>Body, bend exits and mounting points<\/td>\n<td>Controls fit and routing<\/td>\n<td>Dimensioned outline<\/td>\n<\/tr>\n<tr>\n<td>Acc\u00e8s au service<\/td>\n<td>Cleaning, replacement and labels<\/td>\n<td>Affects restoration time<\/td>\n<td>Populated enclosure trial<\/td>\n<\/tr>\n<tr>\n<td>Optical evidence<\/td>\n<td>Port-level loss and uniformity<\/td>\n<td>Links package to tested device<\/td>\n<td>Serialized test report<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter package types in the Project<\/h2>\n<p>Les commandes ci-dessous \u00e9tablissent un lien entre le plan, l'\u00e9chantillon, le lot de production et le r\u00e9sultat de l'installation. Elles sont d\u00e9lib\u00e9r\u00e9ment ax\u00e9es sur la praticit\u00e9 : chacune d'entre elles g\u00e9n\u00e8re un document que les \u00e9quipes des achats, de l'ing\u00e9nierie et du terrain peuvent consulter ult\u00e9rieurement.<\/p>\n<h3>Design from the enclosure inward<\/h3>\n<p>Reserve space for the package, tails, connectors, splice protectors and minimum routing radius. A module that fits an empty box may still block the cover or adjacent adapters after cabling.<\/p>\n<h3>Separate optical and mechanical requirements<\/h3>\n<p>State the split configuration and optical acceptance separately from package dimensions, cable lengths, connector types and mounting hardware. This prevents a correct optical device from arriving in the wrong mechanical format.<\/p>\n<h3>Approve the installed sample<\/h3>\n<p>Load one representative enclosure with the intended splitter, adapters and pigtails. Verify identification, cleaning access, tail routing and replacement sequence before volume release.<\/p>\n<h3>Control package substitutions<\/h3>\n<p>Require notification when the housing, exit boot, cable or connector supplier changes. Recheck fit and optical records against the approved drawing and sample.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave circuit splitter chip before packaging\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>Contr\u00f4les de r\u00e9ception et de remise<\/h2>\n<p>Convenez de la m\u00e9thode et de la marche \u00e0 suivre avant le d\u00e9but des essais. Un r\u00e9sultat pour lequel le responsable du dossier ou les mesures \u00e0 prendre en cas d'\u00e9chec n'ont pas \u00e9t\u00e9 d\u00e9finis est difficile \u00e0 exploiter lors de la validation de l'exp\u00e9dition ou de la mise en service.<\/p>\n<table>\n<thead>\n<tr>\n<th>V\u00e9rifier<\/th>\n<th>M\u00e9thode<\/th>\n<th>Enregistrer<\/th>\n<th>Mesure en cas de d\u00e9faillance<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Outline fit<\/td>\n<td>Install in target enclosure<\/td>\n<td>Fit photos and dimensions<\/td>\n<td>Revise package or enclosure<\/td>\n<\/tr>\n<tr>\n<td>Tail routing<\/td>\n<td>Route every output<\/td>\n<td>Routing record<\/td>\n<td>Correct length or exit<\/td>\n<\/tr>\n<tr>\n<td>Port identity<\/td>\n<td>Trace input and outputs<\/td>\n<td>Label and continuity map<\/td>\n<td>Relabel before shipment<\/td>\n<\/tr>\n<tr>\n<td>Optical test<\/td>\n<td>Measure each required port<\/td>\n<td>Serialized report<\/td>\n<td>Quarantine failing unit<\/td>\n<\/tr>\n<tr>\n<td>P\u00e9riode d'essai du service<\/td>\n<td>Clean and replace sample<\/td>\n<td>Technician sign-off<\/td>\n<td>Improve access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter used in an FTTH distribution point\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>Normes et justificatifs \u00e0 joindre au bon de commande<\/h2>\n<p>Corning pr\u00e9sente les formats des composants, des modules et des racks, et pr\u00e9cise que sa gamme de s\u00e9parateurs PLC est conforme aux normes GR-1209\/1221. Voir <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">R\u00e9f\u00e9rence relative \u00e0 la qualification des s\u00e9parateurs de Corning PLC<\/a>.<\/p>\n<p>Le document de 2025 d\u00e9crit les normes GPON, XG(S)-PON, 50G-PON ainsi que les r\u00e9f\u00e9rences relatives \u00e0 la coexistence dans les r\u00e9seaux d'acc\u00e8s. Voir <a href=\"https:\/\/www.itu.int\/epublications\/en\/publication\/itu-t-gstp-bain-2025-03-broadband-access-and-in-premises-networks\" target=\"_blank\" rel=\"noopener\">Document technique de l'UIT sur l'acc\u00e8s \u00e0 haut d\u00e9bit<\/a>.<\/p>\n<p>La recommandation de 2024 actuellement en vigueur d\u00e9finit les cat\u00e9gories de fibres monomodes insensibles \u00e0 la flexion ainsi que leur champ d'application. Voir <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.657-202408-I\" target=\"_blank\" rel=\"noopener\">Recommandation UIT-T G.657 relative aux fibres insensibles \u00e0 la courbure<\/a>.<\/p>\n<h2>RFQ checklist<\/h2>\n<p>Package selection is an enclosure-engineering decision as well as an optical purchase. Freeze the outline, fibre presentation, label scheme and port-level test record in the same approval package.<\/p>\n<ul>\n<li>Name the target enclosure<\/li>\n<li>Request a controlled outline drawing<\/li>\n<li>Specify tail and connector presentation<\/li>\n<li>Approve a populated sample<\/li>\n<li>Link each serial number to optical results<\/li>\n<\/ul>\n<p>Pour obtenir un devis sur mesure, consultez le site de Fenxi <a href=\"https:\/\/www.fenxifiber.com\/fr\/product-category\/repartiteur-de-fibre-optique\/\" target=\"_blank\" rel=\"noopener\">Gamme de s\u00e9parateurs \u00e0 fibre optique<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/fr\/product\/splitter-fibre-optique-sc-apc-116-low-loss-plc-fiber-splitter\/\" target=\"_blank\" rel=\"noopener\">R\u00e9partiteur PLC APC 1\u00d716 SC<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/fr\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">Comparaison entre les r\u00e9partiteurs PLC et FBT<\/a>, et <a href=\"https:\/\/www.fenxifiber.com\/fr\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">Guide de planification du budget de puissance PON<\/a>. Veuillez nous communiquer le march\u00e9 cible, les interfaces de raccordement, le type de fibre, la structure du c\u00e2ble, les quantit\u00e9s, la r\u00e9vision du plan et les rapports d'essais requis. La r\u00e9ponse permettra alors de distinguer les options standard du catalogue des articles n\u00e9cessitant une confirmation ou un outillage sur mesure.<\/p>","protected":false},"excerpt":{"rendered":"<p>Comparez les ensembles de r\u00e9partiteurs PLC \u00ab nus \u00bb, \u00e0 tubes d'acier, ABS, LGX, \u00e0 cassette et en rack en fonction de leur adaptation au bo\u00eetier, de l'acc\u00e8s aux connecteurs, de l'acheminement, de la protection, des tests et de l'\u00e9tiquetage.<\/p>","protected":false},"author":1,"featured_media":1131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/posts\/1240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/comments?post=1240"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/posts\/1240\/revisions"}],"predecessor-version":[{"id":1241,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/posts\/1240\/revisions\/1241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/media\/1131"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/media?parent=1240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/categories?post=1240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/fr\/wp-json\/wp\/v2\/tags?post=1240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}