{"id":1240,"date":"2026-10-15T04:19:00","date_gmt":"2026-10-15T04:19:00","guid":{"rendered":"https:\/\/www.fenxifiber.com\/plc-splitter-package-types\/"},"modified":"2026-10-02T09:59:33","modified_gmt":"2026-10-02T09:59:33","slug":"plc-splitter-package-types","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/pt\/plc-splitter-package-types\/","title":{"rendered":"Tipos de pacotes de divisores PLC: Mini ABS LGX sem gabinete e em rack"},"content":{"rendered":"<p><strong>Choose the PLC splitter package after the cabinet, closure or rack interface is fixed. The optical circuit may be similar across formats, but tube diameter, pigtail exit, connector presentation, mounting method and technician access determine whether the assembly can be installed and serviced.<\/strong><\/p>\n<p>Bare-fibre and steel-tube units suit protected internal integration; ABS modules add mechanical protection; LGX, cassette and rack formats provide connectorized presentation and mounting features. Package names are not universal dimensional standards, so procurement should request a controlled outline drawing and test a production-representative sample in the target enclosure.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-package-styles.jpg\" alt=\"PLC splitter package formats for enclosure and rack selection\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>What Must Be Decided for PLC splitter package types?<\/h2>\n<p>Utilize a tabela de decis\u00e3o para transformar o t\u00f3pico em par\u00e2metros controlados de compra, projeto e aceita\u00e7\u00e3o. Cada linha deve ser confirmada com base no equipamento real, na rota e no padr\u00e3o de destino, em vez de ser copiada de um cat\u00e1logo gen\u00e9rico.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u00c1rea de decis\u00e3o<\/th>\n<th>O que especificar<\/th>\n<th>Por que isso \u00e9 importante<\/th>\n<th>Provas a serem mantidas<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Installation location<\/td>\n<td>Closure, wall box, cabinet or rack<\/td>\n<td>Defines protection and mounting needs<\/td>\n<td>Approved enclosure drawing<\/td>\n<\/tr>\n<tr>\n<td>Fibre presentation<\/td>\n<td>Bare fibre, pigtails or adapters<\/td>\n<td>Changes splicing and patching work<\/td>\n<td>Port and tail schedule<\/td>\n<\/tr>\n<tr>\n<td>Mechanical envelope<\/td>\n<td>Body, bend exits and mounting points<\/td>\n<td>Controls fit and routing<\/td>\n<td>Dimensioned outline<\/td>\n<\/tr>\n<tr>\n<td>Service access<\/td>\n<td>Cleaning, replacement and labels<\/td>\n<td>Affects restoration time<\/td>\n<td>Populated enclosure trial<\/td>\n<\/tr>\n<tr>\n<td>Optical evidence<\/td>\n<td>Port-level loss and uniformity<\/td>\n<td>Links package to tested device<\/td>\n<td>Relat\u00f3rio de teste em s\u00e9rie<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>How to Control PLC splitter package types in the Project<\/h2>\n<p>Os controles abaixo relacionam o desenho, a amostra, o lote de produ\u00e7\u00e3o e o resultado da instala\u00e7\u00e3o. Eles s\u00e3o deliberadamente pr\u00e1ticos: cada um gera um registro que as equipes de compras, engenharia e de campo podem analisar posteriormente.<\/p>\n<h3>Design from the enclosure inward<\/h3>\n<p>Reserve space for the package, tails, connectors, splice protectors and minimum routing radius. A module that fits an empty box may still block the cover or adjacent adapters after cabling.<\/p>\n<h3>Separate optical and mechanical requirements<\/h3>\n<p>State the split configuration and optical acceptance separately from package dimensions, cable lengths, connector types and mounting hardware. This prevents a correct optical device from arriving in the wrong mechanical format.<\/p>\n<h3>Approve the installed sample<\/h3>\n<p>Load one representative enclosure with the intended splitter, adapters and pigtails. Verify identification, cleaning access, tail routing and replacement sequence before volume release.<\/p>\n<h3>Control package substitutions<\/h3>\n<p>Require notification when the housing, exit boot, cable or connector supplier changes. Recheck fit and optical records against the approved drawing and sample.<\/p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/h2-plc-waveguide-chip.jpg\" alt=\"Planar lightwave circuit splitter chip before packaging\" width=\"1337\" height=\"861\" \/><\/figure>\n<h2>Verifica\u00e7\u00f5es de aceita\u00e7\u00e3o e entrega<\/h2>\n<p>Chegue a um acordo sobre o m\u00e9todo e o procedimento antes do in\u00edcio dos testes. Um resultado sem um respons\u00e1vel definido pelo registro ou sem uma a\u00e7\u00e3o a ser tomada em caso de falha \u00e9 dif\u00edcil de ser utilizado durante a libera\u00e7\u00e3o da remessa ou o comissionamento.<\/p>\n<table>\n<thead>\n<tr>\n<th>Verificar<\/th>\n<th>M\u00e9todo<\/th>\n<th>Registro<\/th>\n<th>A\u00e7\u00e3o em caso de falha<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Outline fit<\/td>\n<td>Install in target enclosure<\/td>\n<td>Fit photos and dimensions<\/td>\n<td>Revise package or enclosure<\/td>\n<\/tr>\n<tr>\n<td>Tail routing<\/td>\n<td>Route every output<\/td>\n<td>Routing record<\/td>\n<td>Correct length or exit<\/td>\n<\/tr>\n<tr>\n<td>Port identity<\/td>\n<td>Trace input and outputs<\/td>\n<td>Label and continuity map<\/td>\n<td>Relabel before shipment<\/td>\n<\/tr>\n<tr>\n<td>Teste \u00f3ptico<\/td>\n<td>Measure each required port<\/td>\n<td>Serialized report<\/td>\n<td>Quarantine failing unit<\/td>\n<\/tr>\n<tr>\n<td>Service trial<\/td>\n<td>Clean and replace sample<\/td>\n<td>Technician sign-off<\/td>\n<td>Improve access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/01\/Optical-Splitter-SC-APC-2.jpg\" alt=\"Connectorized PLC splitter used in an FTTH distribution point\" width=\"800\" height=\"800\" \/><\/figure>\n<h2>Padr\u00f5es e evid\u00eancias para fundamentar a ordem de compra<\/h2>\n<p>A Corning apresenta os formatos de componentes, m\u00f3dulos e racks e indica a certifica\u00e7\u00e3o GR-1209\/1221 para sua linha de divisores PLC. Consulte <a href=\"https:\/\/www.corning.com\/oem-solutions\/worldwide\/en\/home\/products-solutions\/optical-communication-components\/taps-couplers-splitters\/plc-splitters.html\" target=\"_blank\" rel=\"noopener\">Refer\u00eancia de qualifica\u00e7\u00e3o do divisor da Corning PLC<\/a>.<\/p>\n<p>O artigo de 2025 descreve refer\u00eancias sobre GPON, XG(S)-PON, 50G-PON e coexist\u00eancia para redes de acesso. Consulte <a href=\"https:\/\/www.itu.int\/epublications\/en\/publication\/itu-t-gstp-bain-2025-03-broadband-access-and-in-premises-networks\" target=\"_blank\" rel=\"noopener\">Documento t\u00e9cnico da ITU sobre acesso \u00e0 banda larga<\/a>.<\/p>\n<p>A recomenda\u00e7\u00e3o de 2024, atualmente em vigor, define as categorias de fibras monomodo insens\u00edveis \u00e0 flex\u00e3o e seu escopo de aplica\u00e7\u00e3o. Consulte <a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.657-202408-I\" target=\"_blank\" rel=\"noopener\">Recomenda\u00e7\u00e3o ITU-T G.657 sobre fibras insens\u00edveis \u00e0 curvatura<\/a>.<\/p>\n<h2>RFQ checklist<\/h2>\n<p>Package selection is an enclosure-engineering decision as well as an optical purchase. Freeze the outline, fibre presentation, label scheme and port-level test record in the same approval package.<\/p>\n<ul>\n<li>Name the target enclosure<\/li>\n<li>Request a controlled outline drawing<\/li>\n<li>Specify tail and connector presentation<\/li>\n<li>Approve a populated sample<\/li>\n<li>Link each serial number to optical results<\/li>\n<\/ul>\n<p>Para obter um or\u00e7amento espec\u00edfico para o projeto, consulte a Fenxi\u2019s <a href=\"https:\/\/www.fenxifiber.com\/pt\/product-category\/divisor-de-fibra-optica\/\" target=\"_blank\" rel=\"noopener\">linha de divisores de fibra \u00f3ptica<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/pt\/product\/divisor-de-fibra-optica-sc-apc-116-divisor-de-fibra-plc-de-baixa-perda\/\" target=\"_blank\" rel=\"noopener\">Divisor 1\u00d716 SC APC PLC<\/a>, <a href=\"https:\/\/www.fenxifiber.com\/pt\/plc-vs-fbt-splitter\/\" target=\"_blank\" rel=\"noopener\">Compara\u00e7\u00e3o entre divisores PLC e FBT<\/a>, e <a href=\"https:\/\/www.fenxifiber.com\/pt\/pon-power-budget-split-ratio\/\" target=\"_blank\" rel=\"noopener\">Guia de planejamento do or\u00e7amento de pot\u00eancia da PON<\/a>. Envie o mercado de destino, as interfaces dos conectores, o tipo de fibra, a constru\u00e7\u00e3o do cabo, as quantidades, a revis\u00e3o do desenho e os registros de teste necess\u00e1rios. A resposta poder\u00e1, ent\u00e3o, distinguir as op\u00e7\u00f5es padr\u00e3o do cat\u00e1logo dos itens que precisam de confirma\u00e7\u00e3o ou de ferramentas personalizadas.<\/p>","protected":false},"excerpt":{"rendered":"<p>Compare os modelos de divisores de PLC do tipo \u201cbare\u201d, de tubo de a\u00e7o, ABS, LGX, cassete e rack quanto ao encaixe no gabinete, acesso aos conectores, roteamento, prote\u00e7\u00e3o, testes e etiquetagem.<\/p>","protected":false},"author":1,"featured_media":1131,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/posts\/1240","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/comments?post=1240"}],"version-history":[{"count":1,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/posts\/1240\/revisions"}],"predecessor-version":[{"id":1241,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/posts\/1240\/revisions\/1241"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/media\/1131"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/media?parent=1240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/categories?post=1240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/tags?post=1240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}