{"id":928,"date":"2026-02-04T03:26:49","date_gmt":"2026-02-04T03:26:49","guid":{"rendered":"https:\/\/www.fenxifiber.com\/?post_type=product&#038;p=928"},"modified":"2026-02-05T02:18:22","modified_gmt":"2026-02-05T02:18:22","slug":"fc-pc-2-0-3-0mm-nao-ajustavel","status":"publish","type":"product","link":"https:\/\/www.fenxifiber.com\/pt\/product\/fc-pc-2-0-3-0mm-non-adjustable\/","title":{"rendered":"Conector de fibra \u00f3ptica n\u00e3o ajust\u00e1vel FC PC 2,0\/3,0 mm"},"content":{"rendered":"<h3 data-start=\"791\" data-end=\"816\">Por que n\u00e3o ajust\u00e1vel?<\/h3>\n<p data-start=\"818\" data-end=\"981\">Ao contr\u00e1rio dos conectores ajust\u00e1veis, esse modelo usa um <strong data-start=\"866\" data-end=\"901\">estrutura de virola fixada na f\u00e1brica<\/strong>.<br data-start=\"902\" data-end=\"905\" \/>Isso significa que cada conector \u00e9 alinhado e ajustado durante a produ\u00e7\u00e3o, proporcionando a voc\u00ea:<\/p>\n<ul data-start=\"983\" data-end=\"1110\">\n<li data-start=\"983\" data-end=\"1022\">\n<p data-start=\"985\" data-end=\"1022\">Desempenho \u00f3ptico mais consistente<\/p>\n<\/li>\n<li data-start=\"1023\" data-end=\"1048\">\n<p data-start=\"1025\" data-end=\"1048\">Montagem mais r\u00e1pida do cabo<\/p>\n<\/li>\n<li data-start=\"1049\" data-end=\"1073\">\n<p data-start=\"1051\" data-end=\"1073\">Menor taxa de rejei\u00e7\u00e3o<\/p>\n<\/li>\n<li data-start=\"1074\" data-end=\"1110\">\n<p data-start=\"1076\" data-end=\"1110\">Melhor uniformidade de lote para lote<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1112\" data-end=\"1328\">Isso o torna especialmente adequado para <strong data-start=\"1150\" data-end=\"1203\">produ\u00e7\u00e3o em massa de patch cords e pigtails de fibra<\/strong>, que \u00e9 exatamente o que os fabricantes profissionais, como a <strong data-start=\"1262\" data-end=\"1318\">Tecnologia Optoeletr\u00f4nica Co. de Changzhou Fenxi, Ltd.<\/strong> foco em.<\/p>\n<hr data-start=\"1330\" data-end=\"1333\" \/>\n<h3 data-start=\"1335\" data-end=\"1380\">Projetado para cabos de fibra de 2,0 mm e 3,0 mm<\/h3>\n<p data-start=\"1382\" data-end=\"1445\">Esse conector \u00e9 compat\u00edvel com os dois tamanhos mais comuns de revestimento de fibra:<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1447\" data-end=\"1614\">\n<thead data-start=\"1447\" data-end=\"1475\">\n<tr data-start=\"1447\" data-end=\"1475\">\n<th class=\"\" data-start=\"1447\" data-end=\"1460\" data-col-size=\"sm\">Tipo de cabo<\/th>\n<th class=\"\" data-start=\"1460\" data-end=\"1475\" data-col-size=\"md\">Uso t\u00edpico<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1503\" data-end=\"1614\">\n<tr data-start=\"1503\" data-end=\"1556\">\n<td data-start=\"1503\" data-end=\"1515\" data-col-size=\"sm\"><strong data-start=\"1505\" data-end=\"1514\">2,0 mm<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1515\" data-end=\"1556\">Patch cords internos, jumpers de equipamentos<\/td>\n<\/tr>\n<tr data-start=\"1557\" data-end=\"1614\">\n<td data-start=\"1557\" data-end=\"1569\" data-col-size=\"sm\"><strong data-start=\"1559\" data-end=\"1568\">3,0 mm<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1569\" data-end=\"1614\">Patch cords de n\u00edvel de telecomunica\u00e7\u00f5es, links de backbone<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1616\" data-end=\"1782\">Independentemente de voc\u00ea estar construindo jumpers curtos para equipamentos ou patch cords de telecomunica\u00e7\u00f5es de longa dist\u00e2ncia, esse conector FC PC se adapta a ambos sem alterar a estrutura \u00f3ptica interna.<\/p>\n<hr data-start=\"1784\" data-end=\"1787\" \/>\n<h3 data-start=\"1789\" data-end=\"1830\">Desempenho \u00f3ptico em que voc\u00ea pode confiar<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1832\" data-end=\"2111\">\n<thead data-start=\"1832\" data-end=\"1867\">\n<tr data-start=\"1832\" data-end=\"1867\">\n<th class=\"\" data-start=\"1832\" data-end=\"1844\" data-col-size=\"sm\">Par\u00e2metro<\/th>\n<th class=\"\" data-start=\"1844\" data-end=\"1867\" data-col-size=\"sm\">Desempenho t\u00edpico<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1900\" data-end=\"2111\">\n<tr data-start=\"1900\" data-end=\"1937\">\n<td data-start=\"1900\" data-end=\"1913\" data-col-size=\"sm\">Tipo de fibra<\/td>\n<td data-col-size=\"sm\" data-start=\"1913\" data-end=\"1937\">Modo \u00fanico 9\/125 \u00b5m<\/td>\n<\/tr>\n<tr data-start=\"1938\" data-end=\"1977\">\n<td data-start=\"1938\" data-end=\"1952\" data-col-size=\"sm\">Tipo de polon\u00eas<\/td>\n<td data-col-size=\"sm\" data-start=\"1952\" data-end=\"1977\">PC (contato f\u00edsico)<\/td>\n<\/tr>\n<tr data-start=\"1978\" data-end=\"2008\">\n<td data-start=\"1978\" data-end=\"1995\" data-col-size=\"sm\">Perda de inser\u00e7\u00e3o<\/td>\n<td data-col-size=\"sm\" data-start=\"1995\" data-end=\"2008\">\u2264 0,30 dB<\/td>\n<\/tr>\n<tr data-start=\"2009\" data-end=\"2034\">\n<td data-start=\"2009\" data-end=\"2023\" data-col-size=\"sm\">Perda de retorno<\/td>\n<td data-col-size=\"sm\" data-start=\"2023\" data-end=\"2034\">\u2265 45 dB<\/td>\n<\/tr>\n<tr data-start=\"2035\" data-end=\"2079\">\n<td data-start=\"2035\" data-end=\"2058\" data-col-size=\"sm\">Comprimento de onda operacional<\/td>\n<td data-col-size=\"sm\" data-start=\"2058\" data-end=\"2079\">1310 nm \/ 1550 nm<\/td>\n<\/tr>\n<tr data-start=\"2080\" data-end=\"2111\">\n<td data-start=\"2080\" data-end=\"2094\" data-col-size=\"sm\">Vida de acasalamento<\/td>\n<td data-col-size=\"sm\" data-start=\"2094\" data-end=\"2111\">\u2265 1000 ciclos<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2113\" data-end=\"2208\">Esses valores atendem aos requisitos padr\u00e3o para redes \u00f3pticas de telecomunica\u00e7\u00f5es, FTTH e corporativas.<\/p>\n<hr data-start=\"2210\" data-end=\"2213\" \/>\n<h3 data-start=\"2215\" data-end=\"2256\">Criado para ambientes de rede reais<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2258\" data-end=\"2511\">\n<thead data-start=\"2258\" data-end=\"2285\">\n<tr data-start=\"2258\" data-end=\"2285\">\n<th class=\"\" data-start=\"2258\" data-end=\"2268\" data-col-size=\"sm\">Recurso<\/th>\n<th class=\"\" data-start=\"2268\" data-end=\"2285\" data-col-size=\"sm\">Especifica\u00e7\u00e3o<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2313\" data-end=\"2511\">\n<tr data-start=\"2313\" data-end=\"2339\">\n<td data-start=\"2313\" data-end=\"2330\" data-col-size=\"sm\">Tipo de conector<\/td>\n<td data-col-size=\"sm\" data-start=\"2330\" data-end=\"2339\">FC PC<\/td>\n<\/tr>\n<tr data-start=\"2340\" data-end=\"2370\">\n<td data-start=\"2340\" data-end=\"2353\" data-col-size=\"sm\">Tamanho do cabo<\/td>\n<td data-col-size=\"sm\" data-start=\"2353\" data-end=\"2370\">2,0 mm \/ 3,0 mm<\/td>\n<\/tr>\n<tr data-start=\"2371\" data-end=\"2401\">\n<td data-start=\"2371\" data-end=\"2381\" data-col-size=\"sm\">Ponteira<\/td>\n<td data-col-size=\"sm\" data-start=\"2381\" data-end=\"2401\">Cer\u00e2mica de zirc\u00f4nia<\/td>\n<\/tr>\n<tr data-start=\"2402\" data-end=\"2437\">\n<td data-start=\"2402\" data-end=\"2413\" data-col-size=\"sm\">Acoplamento<\/td>\n<td data-col-size=\"sm\" data-start=\"2413\" data-end=\"2437\">Parafuso de metal com rosca<\/td>\n<\/tr>\n<tr data-start=\"2438\" data-end=\"2480\">\n<td data-start=\"2438\" data-end=\"2462\" data-col-size=\"sm\">Temperatura operacional<\/td>\n<td data-col-size=\"sm\" data-start=\"2462\" data-end=\"2480\">-40\u00b0C a +75\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"2481\" data-end=\"2511\">\n<td data-start=\"2481\" data-end=\"2500\" data-col-size=\"sm\">Resist\u00eancia \u00e0 tra\u00e7\u00e3o<\/td>\n<td data-col-size=\"sm\" data-start=\"2500\" data-end=\"2511\">\u2265 200 N<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2513\" data-end=\"2660\">O <strong data-start=\"2517\" data-end=\"2541\">Acoplamento roscado FC<\/strong> garante que, uma vez conectada, a fibra permane\u00e7a travada no lugar, mesmo em racks, gabinetes ou gabinetes de telecomunica\u00e7\u00f5es externos.<\/p>\n<hr data-start=\"2662\" data-end=\"2665\" \/>\n<h3 data-start=\"2667\" data-end=\"2710\">Onde esse conector \u00e9 comumente usado<\/h3>\n<p data-start=\"2712\" data-end=\"2756\">Voc\u00ea encontrar\u00e1 conectores FC PC 2.0\/3.0 mm em:<\/p>\n<ul data-start=\"2758\" data-end=\"2967\">\n<li data-start=\"2758\" data-end=\"2798\">\n<p data-start=\"2760\" data-end=\"2798\">Backbone de telecomunica\u00e7\u00f5es e redes de acesso<\/p>\n<\/li>\n<li data-start=\"2799\" data-end=\"2823\">\n<p data-start=\"2801\" data-end=\"2823\">Sistemas FTTH e PON<\/p>\n<\/li>\n<li data-start=\"2824\" data-end=\"2858\">\n<p data-start=\"2826\" data-end=\"2858\">Patch cords e pigtails de fibra<\/p>\n<\/li>\n<li data-start=\"2859\" data-end=\"2892\">\n<p data-start=\"2861\" data-end=\"2892\">Estruturas ODF e gabinetes de fibra<\/p>\n<\/li>\n<li data-start=\"2893\" data-end=\"2924\">\n<p data-start=\"2895\" data-end=\"2924\">Redes CATV e de banda larga<\/p>\n<\/li>\n<li data-start=\"2925\" data-end=\"2967\">\n<p data-start=\"2927\" data-end=\"2967\">Equipamentos \u00f3pticos de teste e medi\u00e7\u00e3o<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2969\" data-end=\"3058\">Em qualquer lugar em que sejam necess\u00e1rias conex\u00f5es de fibra est\u00e1veis e de baixa perda, esse conector se encaixa naturalmente.<\/p>\n<hr data-start=\"3060\" data-end=\"3063\" \/>\n<h2 data-start=\"3065\" data-end=\"3086\">Perguntas e respostas profissionais<\/h2>\n<p data-start=\"3088\" data-end=\"3265\"><strong data-start=\"3088\" data-end=\"3139\">P1: O FC PC e o FC APC podem ser conectados juntos?<\/strong><br data-start=\"3139\" data-end=\"3142\" \/>N\u00e3o. O FC PC tem uma extremidade plana, enquanto o FC APC \u00e9 angular. A conex\u00e3o entre eles causar\u00e1 <strong data-start=\"3224\" data-end=\"3264\">alta perda e pode danificar o ferrolho<\/strong>.<\/p>\n<hr data-start=\"3267\" data-end=\"3270\" \/>\n<p data-start=\"3272\" data-end=\"3494\"><strong data-start=\"3272\" data-end=\"3324\">P2: Quando devo escolher 2,0 mm em vez de 3,0 mm?<\/strong><br data-start=\"3324\" data-end=\"3327\" \/>2,0 mm \u00e9 normalmente usado para <strong data-start=\"3355\" data-end=\"3399\">jumpers para equipamentos e patch cords internos<\/strong>, enquanto 3,0 mm \u00e9 o preferido para <strong data-start=\"3430\" data-end=\"3461\">cabos de telecomunica\u00e7\u00f5es e de backbone<\/strong> com maior resist\u00eancia mec\u00e2nica.<\/p>\n<hr data-start=\"3496\" data-end=\"3499\" \/>\n<p data-start=\"3501\" data-end=\"3709\"><strong data-start=\"3501\" data-end=\"3550\">P3: O n\u00e3o ajust\u00e1vel \u00e9 melhor do que o ajust\u00e1vel?<\/strong><br data-start=\"3550\" data-end=\"3553\" \/>Para <strong data-start=\"3557\" data-end=\"3598\">patch cords e pigtails fabricados na f\u00e1brica<\/strong>, Sim. Os conectores n\u00e3o ajust\u00e1veis fornecem <strong data-start=\"3636\" data-end=\"3708\">melhor consist\u00eancia, montagem mais r\u00e1pida e qualidade \u00f3ptica mais est\u00e1vel<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<h3 data-start=\"170\" data-end=\"227\">Um conector FC confi\u00e1vel para as redes de fibra do dia a dia<\/h3>\n<p data-start=\"229\" data-end=\"513\">O <strong data-start=\"233\" data-end=\"277\">Conector n\u00e3o ajust\u00e1vel FC PC 2.0\/3.0 mm<\/strong> foi criado para uma coisa: <strong data-start=\"302\" data-end=\"341\">desempenho est\u00e1vel e duradouro da fibra<\/strong>.<br data-start=\"342\" data-end=\"345\" \/>Ele foi projetado para <strong data-start=\"364\" data-end=\"420\">cabos de fibra monomodo com revestimentos de 2,0 mm ou 3,0 mm<\/strong>, tornando-o ideal para patch cords de telecomunica\u00e7\u00f5es padr\u00e3o, pigtails e sistemas de distribui\u00e7\u00e3o de fibra.<\/p>\n<p data-start=\"515\" data-end=\"784\">Com sua <strong data-start=\"524\" data-end=\"579\">Virola de cer\u00e2mica polida plana PC (Physical Contact)<\/strong> e <strong data-start=\"584\" data-end=\"613\">Caixa met\u00e1lica FC rosqueada<\/strong>, Esse conector fornece um <strong data-start=\"641\" data-end=\"673\">conex\u00e3o mec\u00e2nica segura<\/strong> e <strong data-start=\"678\" data-end=\"711\">perda \u00f3ptica consistentemente baixa<\/strong>-mesmo em ambientes onde a vibra\u00e7\u00e3o ou a reconex\u00e3o repetida \u00e9 comum.<\/p>","protected":false},"featured_media":929,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[34],"product_tag":[],"class_list":["post-928","product","type-product","status-publish","has-post-thumbnail","product_cat-fc-connector","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/product\/928","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/comments?post=928"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/media\/929"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/media?parent=928"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/product_brand?post=928"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/product_cat?post=928"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/pt\/wp-json\/wp\/v2\/product_tag?post=928"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}