<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LC Çift Yönlü Konnektörler (Tek Modlu ve Çok Modlu) - Fenxi Optoelectronics Technology</title>
	<atom:link href="https://www.fenxifiber.com/tr/product-category/lc-connector/lc-duplex-connectors-single-modemultimode/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.fenxifiber.com/tr</link>
	<description></description>
	<lastBuildDate>Thu, 05 Feb 2026 02:37:21 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updateperiod>
	saatlik	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://www.fenxifiber.com/wp-content/uploads/2026/01/FENXI-LOGO-F-100x100.jpg</url>
	<title>LC Çift Yönlü Konnektörler (Tek Modlu ve Çok Modlu) - Fenxi Optoelectronics Technology</title>
	<link>https://www.fenxifiber.com/tr</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>LC UPC 3.0mm Dubleks Çok Modlu (Göl Mavisi) Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu-gol-mavisi/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu-gol-mavisi/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 03:02:57 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=890</guid>

					<description><![CDATA[<p data-start="180" data-end="551">Büyük veri merkezlerinde ve kurumsal fiber odalarında kablolar artık sadece bağlantı değil, aynı zamanda <strong data-start="279" data-end="312">yönetim sisteminin bir parçası</strong>.<br data-start="313" data-end="316" />Bu <strong data-start="320" data-end="387">LC UPC 3.0mm Dubleks Çok Modlu (Göl Mavisi) Fiber Optik Konnektör</strong> ekler <strong data-start="393" data-end="424">net görsel tanımlama</strong> bir <strong data-start="430" data-end="457">yüksek hızlı optik bağlantı</strong>, mühendislerin çok modlu devreleri tek modlu ve yedek rotalardan hızlı bir şekilde ayırt etmelerine yardımcı olur.</p>
<p data-start="553" data-end="714">Bu <strong data-start="557" data-end="577">Göl Mavisi ceket</strong> genellikle tanımlamak için kullanılır <strong data-start="607" data-end="638">OM3 ve OM4 çok modlu fiber</strong>, Kurulum veya bakım sırasında yanlış bağlantı riskini azaltır.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="721" data-end="780">Renk kodlu çok modlu ağların yönetimini kolaylaştırır</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="782" data-end="992">
<thead data-start="782" data-end="827">
<tr data-start="782" data-end="827">
<th class="" data-start="782" data-end="797" data-col-size="sm">Ceket rengi</th>
<th class="" data-start="797" data-end="827" data-col-size="sm">Genellikle neyi temsil eder</th>
</tr>
</thead>
<tbody data-start="873" data-end="992">
<tr data-start="873" data-end="897">
<td data-start="873" data-end="882" data-col-size="sm">Sarı</td>
<td data-start="882" data-end="897" data-col-size="sm">Tek modlu</td>
</tr>
<tr data-start="898" data-end="930">
<td data-start="898" data-end="907" data-col-size="sm">Turuncu</td>
<td data-start="907" data-end="930" data-col-size="sm">OM1 / OM2 çok modlu</td>
</tr>
<tr data-start="931" data-end="992">
<td data-start="931" data-end="954" data-col-size="sm"><strong data-start="933" data-end="953">Göl Mavisi (Aqua)</strong></td>
<td data-col-size="sm" data-start="954" data-end="992"><strong data-start="956" data-end="990">OM3 / OM4 yüksek hızlı çok modlu</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="994" data-end="1086">Bu görsel standart şu alanlarda yaygın olarak kullanılmaktadır <strong data-start="1033" data-end="1085">veri merkezleri, bulut tesisleri ve telekom odaları</strong>.</p>
<hr data-start="1088" data-end="1091" />
<h3 data-start="1093" data-end="1142">3.0mm dubleks - yapılandırılmış kablolama için üretilmiştir</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1144" data-end="1307">
<thead data-start="1144" data-end="1173">
<tr data-start="1144" data-end="1173">
<th class="" data-start="1144" data-end="1157" data-col-size="sm">Kablo boyutu</th>
<th class="" data-start="1157" data-end="1173" data-col-size="md">Tipik rol</th>
</tr>
</thead>
<tbody data-start="1203" data-end="1307">
<tr data-start="1203" data-end="1242">
<td data-start="1203" data-end="1211" data-col-size="sm">2.0mm</td>
<td data-col-size="md" data-start="1211" data-end="1242">Anahtar bağlantı noktalarındaki yama kabloları</td>
</tr>
<tr data-start="1243" data-end="1307">
<td data-start="1243" data-end="1255" data-col-size="sm"><strong data-start="1245" data-end="1254">3.0mm</strong></td>
<td data-start="1255" data-end="1307" data-col-size="md"><strong data-start="1257" data-end="1305">Raflar, kablo kanalları, kabinden kabine bağlantılar</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1309" data-end="1432">Daha kalın kılıf, çok modlu fiberleri yoğun kablolama yollarından geçirildiğinde bükülme kaybına ve fiziksel gerilime karşı korur.</p>
<hr data-start="1434" data-end="1437" />
<h3 data-start="1439" data-end="1474">Çok modlu optik performans</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1476" data-end="1727">
<thead data-start="1476" data-end="1505">
<tr data-start="1476" data-end="1505">
<th class="" data-start="1476" data-end="1488" data-col-size="sm">Parametre</th>
<th class="" data-start="1488" data-end="1505" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1535" data-end="1727">
<tr data-start="1535" data-end="1561">
<td data-start="1535" data-end="1548" data-col-size="sm">Fiber tipi</td>
<td data-start="1548" data-end="1561" data-col-size="sm">OM3 / OM4</td>
</tr>
<tr data-start="1562" data-end="1587">
<td data-start="1562" data-end="1574" data-col-size="sm">Çekirdek boyutu</td>
<td data-start="1574" data-end="1587" data-col-size="sm">50/125 µm</td>
</tr>
<tr data-start="1588" data-end="1606">
<td data-start="1588" data-end="1599" data-col-size="sm">Uç yüz</td>
<td data-start="1599" data-end="1606" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1607" data-end="1637">
<td data-start="1607" data-end="1624" data-col-size="sm">Ekleme kaybı</td>
<td data-col-size="sm" data-start="1624" data-end="1637">≤ 0,30 dB</td>
</tr>
<tr data-start="1638" data-end="1663">
<td data-start="1638" data-end="1652" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1652" data-end="1663" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1664" data-end="1695">
<td data-start="1664" data-end="1678" data-col-size="sm">Dalga Boyları</td>
<td data-start="1678" data-end="1695" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1696" data-end="1727">
<td data-start="1696" data-end="1710" data-col-size="sm">Çiftleşme hayatı</td>
<td data-start="1710" data-end="1727" data-col-size="sm">≥ 1000 döngü</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1729" data-end="1834">Bu özellikler aşağıdakileri destekler <strong data-start="1759" data-end="1789">10G, 40G ve 100G Ethernet</strong> veri merkezlerinin ve kurumsal ağların içinde.</p>
<hr data-start="1836" data-end="1839" />
<h3 data-start="1841" data-end="1869">Çift yönlü LC yapısı</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1871" data-end="2130">
<thead data-start="1871" data-end="1894">
<tr data-start="1871" data-end="1894">
<th class="" data-start="1871" data-end="1883" data-col-size="sm">Bileşen</th>
<th class="" data-start="1883" data-end="1894" data-col-size="sm">Amaç</th>
</tr>
</thead>
<tbody data-start="1917" data-end="2130">
<tr data-start="1917" data-end="1974">
<td data-start="1917" data-end="1943" data-col-size="sm">1,25 mm seramik yüksükler</td>
<td data-start="1943" data-end="1974" data-col-size="sm">Hassas çok modlu hizalama</td>
</tr>
<tr data-start="1975" data-end="2027">
<td data-start="1975" data-end="2000" data-col-size="sm">UPC cilalı uç yüzeyler</td>
<td data-start="2000" data-end="2027" data-col-size="sm">Kararlı optik bağlantı</td>
</tr>
<tr data-start="2028" data-end="2072">
<td data-start="2028" data-end="2045" data-col-size="sm">Çift yönlü LC klips</td>
<td data-start="2045" data-end="2072" data-col-size="sm">Tx/Rx eşleşmesini korur</td>
</tr>
<tr data-start="2073" data-end="2130">
<td data-start="2073" data-end="2098" data-col-size="sm">3.0mm göl mavisi ceket</td>
<td data-start="2098" data-end="2130" data-col-size="sm">Yüksek görünürlük ve koruma</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2132" data-end="2135" />
<h3 data-start="2137" data-end="2159">Profesyonel Soru-Cevap</h3>
<p data-start="2161" data-end="2328"><strong data-start="2161" data-end="2209">Göl mavisi renk performansı etkiliyor mu?</strong><br data-start="2209" data-end="2212" />Hayır. Renk <strong data-start="2233" data-end="2271">sadece tanımlama ve yönetim</strong>. Optik performans fiber ve cila tarafından tanımlanır.</p>
<p data-start="2330" data-end="2456"><strong data-start="2330" data-end="2383">Bu OM3 ve OM4 alıcı-vericileriyle uyumlu mu?</strong><br data-start="2383" data-end="2386" />Evet. Özellikle şunlar için tasarlanmıştır <strong data-start="2423" data-end="2455">yüksek hızlı çok modlu sistemler</strong>.</p>
<p data-start="2458" data-end="2564"><strong data-start="2458" data-end="2498">Bu LC patch panellerde kullanılabilir mi?</strong><br data-start="2498" data-end="2501" />Evet. LC arayüzü standarttır ve tüm LC UPC adaptörlerine uyar.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu-gol-mavisi/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 3.0mm Dubleks Çok Modlu Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 03:01:52 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=887</guid>

					<description><![CDATA[<p data-start="161" data-end="572">Bu <strong data-start="165" data-end="220">LC UPC 3.0mm Dubleks Çok Modlu Fiber Optik Konnektör</strong> için inşa edilmiştir <strong data-start="234" data-end="275">veri merkezleri ve kurumsal omurgalar</strong> kısa erişimli optik bağlantıların hızlı, istikrarlı ve fiziksel olarak korunmuş kalması gereken yerlerde.<br data-start="358" data-end="361" />Çok modlu fiber aşağıdakiler için yaygın olarak kullanılır <strong data-start="396" data-end="429">10G, 40G ve 100G bağlantıları</strong>, ve daha kalın 3.0mm dubleks kılıf bu bağlantılara <strong data-start="489" data-end="515">mekani̇k güveni̇li̇rli̇k</strong> tepsiler, raflar ve dolaplar aracılığıyla yönlendirildiklerinde ihtiyaç duyarlar.</p>
<p data-start="574" data-end="725">Standart 2.0mm jumperlar ekipman bağlantı noktalarında iyi çalışırken, omurga yolları şunları gerektirir <strong data-start="656" data-end="676">daha güçlü ceketler</strong> mikro bükülmeyi ve sinyal kararsızlığını önlemek için.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="732" data-end="776">Çok modlu kablolamada 3.0mm neden önemlidir?</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="778" data-end="946">
<thead data-start="778" data-end="812">
<tr data-start="778" data-end="812">
<th class="" data-start="778" data-end="795" data-col-size="sm">Kablo çapı</th>
<th class="" data-start="795" data-end="812" data-col-size="sm">Pratik kullanım</th>
</tr>
</thead>
<tbody data-start="847" data-end="946">
<tr data-start="847" data-end="887">
<td data-start="847" data-end="855" data-col-size="sm">2.0mm</td>
<td data-start="855" data-end="887" data-col-size="sm">Anahtar ve alıcı-verici bağlantı noktaları</td>
</tr>
<tr data-start="888" data-end="946">
<td data-start="888" data-end="900" data-col-size="sm"><strong data-start="890" data-end="899">3.0mm</strong></td>
<td data-col-size="sm" data-start="900" data-end="946"><strong data-start="902" data-end="944">Raflar, tepsiler, dolaptan dolaba bağlantılar</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="948" data-end="1046">Daha ağır kılıf, OM fiberini kalabalık kablo yollarında bükülme kaybına ve ezilmeye karşı korur.</p>
<hr data-start="1048" data-end="1051" />
<h3 data-start="1053" data-end="1085">Çok modlu optik davranış</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1087" data-end="1359">
<thead data-start="1087" data-end="1116">
<tr data-start="1087" data-end="1116">
<th class="" data-start="1087" data-end="1099" data-col-size="sm">Parametre</th>
<th class="" data-start="1099" data-end="1116" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1146" data-end="1359">
<tr data-start="1146" data-end="1178">
<td data-start="1146" data-end="1159" data-col-size="sm">Fiber tipi</td>
<td data-start="1159" data-end="1178" data-col-size="sm">OM2 / OM3 / OM4</td>
</tr>
<tr data-start="1179" data-end="1219">
<td data-start="1179" data-end="1191" data-col-size="sm">Çekirdek boyutu</td>
<td data-start="1191" data-end="1219" data-col-size="sm">50/125 µm veya 62,5/125 µm</td>
</tr>
<tr data-start="1220" data-end="1238">
<td data-start="1220" data-end="1231" data-col-size="sm">Uç yüz</td>
<td data-start="1231" data-end="1238" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1239" data-end="1269">
<td data-start="1239" data-end="1256" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1256" data-end="1269" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1270" data-end="1295">
<td data-start="1270" data-end="1284" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1284" data-end="1295" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1296" data-end="1327">
<td data-start="1296" data-end="1310" data-col-size="sm">Dalga Boyları</td>
<td data-start="1310" data-end="1327" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1328" data-end="1359">
<td data-start="1328" data-end="1342" data-col-size="sm">Çiftleşme hayatı</td>
<td data-start="1342" data-end="1359" data-col-size="sm">≥ 1000 döngü</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1361" data-end="1469">Bu değerler şunları destekler <strong data-start="1382" data-end="1436">Ethernet, SAN ve yüksek hızlı optik ara bağlantılar</strong> binaların ve veri salonlarının içinde.</p>
<hr data-start="1471" data-end="1474" />
<h3 data-start="1476" data-end="1498">Çift yönlü LC tasarımı</h3>
<p data-start="1500" data-end="1639">İki fiber bir LC dubleks muhafazada tutularak <strong data-start="1555" data-end="1614">sabit polarite ve senkronize gönderme/alma yolları</strong> bakım sırasında bile.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1641" data-end="1895">
<thead data-start="1641" data-end="1663">
<tr data-start="1641" data-end="1663">
<th class="" data-start="1641" data-end="1651" data-col-size="sm">Element</th>
<th class="" data-start="1651" data-end="1663" data-col-size="sm">Fonksiyon</th>
</tr>
</thead>
<tbody data-start="1685" data-end="1895">
<tr data-start="1685" data-end="1738">
<td data-start="1685" data-end="1711" data-col-size="sm">1,25 mm seramik yüksükler</td>
<td data-start="1711" data-end="1738" data-col-size="sm">Hassas fiber hizalama</td>
</tr>
<tr data-start="1739" data-end="1791">
<td data-start="1739" data-end="1752" data-col-size="sm">UPC cilası</td>
<td data-col-size="sm" data-start="1752" data-end="1791">Çok modlu lazerler için düşük yansıma</td>
</tr>
<tr data-start="1792" data-end="1833">
<td data-start="1792" data-end="1809" data-col-size="sm">Çift yönlü LC klips</td>
<td data-col-size="sm" data-start="1809" data-end="1833">Tx/Rx'i birbirine kilitler</td>
</tr>
<tr data-start="1834" data-end="1895">
<td data-start="1834" data-end="1855" data-col-size="sm">Kalın 3.0mm ceket</td>
<td data-start="1855" data-end="1895" data-col-size="sm">Eğilme ve gerilmelere karşı korur</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1897" data-end="1900" />
<h3 data-start="1902" data-end="1924">Profesyonel Soru-Cevap</h3>
<p data-start="1926" data-end="2090"><strong data-start="1926" data-end="1967">3.0mm LC konektörler için çok mu sert?</strong><br data-start="1967" data-end="1970" />Hayır. LC yüksük ve muhafaza standarttır. Yalnızca kablo daha kalındır ve omurga rotaları için daha iyi koruma sağlar.</p>
<p data-start="2092" data-end="2205"><strong data-start="2092" data-end="2136">Bu OM3 ve OM4 fiber ile kullanılabilir mi?</strong><br data-start="2136" data-end="2139" />Evet. OM2, OM3 ve OM4 çok modlu fiber ile tamamen uyumludur.</p>
<p data-start="2207" data-end="2337"><strong data-start="2207" data-end="2248">Çok modlu bağlantılar için APC kullanmalı mıyım?</strong><br data-start="2248" data-end="2251" />Hayır. Çok modlu sistemler <strong data-start="2277" data-end="2284">UPC</strong>. APC tek modlu yansıma kontrolü için tasarlanmıştır.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-cok-modlu/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 3.0mm Çift Yönlü Tekli Mod Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-tekli%cc%87-mod/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-tekli%cc%87-mod/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 03:00:39 +00000000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=885</guid>

					<description><![CDATA[<p data-start="164" data-end="520">Bu <strong data-start="168" data-end="224">LC UPC 3.0mm Çift Yönlü Tekli Mod Fiber Optik Konnektör</strong> için tasarlanmıştır <strong data-start="241" data-end="288">yıllarca sabit kalması gereken fiber bağlantılar</strong>, sadece bir rafın içinde değil, genelinde <strong data-start="324" data-end="365">katlar, koridorlar ve omurga çerçeveleri</strong>.<br data-start="366" data-end="369" />Yama kablolarının yönlendirildiği yer <strong data-start="406" data-end="463">kablo kanalları, dikey şaftlar veya dağıtım kabinleri</strong>, daha kalın ve daha koruyucu bir ceket gerekli hale gelir.</p>
<p data-start="522" data-end="730">Bu 3.0mm dubleks LC konektör şunları birleştirir <strong data-start="562" data-end="588">düşük kayıplı UPC parlatma</strong> ile <strong data-start="596" data-end="626">güçlendirilmiş kablo yapısı</strong>, arasında güvenilir bir bağlantı oluşturarak <strong data-start="667" data-end="729">optik dağıtım çerçeveleri, anahtarlar ve erişim ekipmanları</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="737" data-end="786">3.0mm dubleks - gerçek kablolama yolları için üretilmiştir</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="788" data-end="982">
<thead data-start="788" data-end="827">
<tr data-start="788" data-end="827">
<th class="" data-start="788" data-end="801" data-col-size="sm">Kablo tipi</th>
<th class="" data-start="801" data-end="827" data-col-size="md">En iyi performans gösterdiği yer</th>
</tr>
</thead>
<tbody data-start="867" data-end="982">
<tr data-start="867" data-end="908">
<td data-start="867" data-end="875" data-col-size="sm">2.0mm</td>
<td data-start="875" data-end="908" data-col-size="md">Cihaz bağlantı noktalarındaki kısa atlama telleri</td>
</tr>
<tr data-start="909" data-end="982">
<td data-start="909" data-end="921" data-col-size="sm"><strong data-start="911" data-end="920">3.0mm</strong></td>
<td data-start="921" data-end="982" data-col-size="md"><strong data-start="923" data-end="980">Bina omurgaları, kattan kata bağlantılar, ODF yönlendirme</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="984" data-end="1094">Daha kalın kılıf çekme kuvvetlerini emer ve lifler uzun yollardan geçirildiğinde mikro bükülmeleri azaltır.</p>
<hr data-start="1096" data-end="1099" />
<h3 data-start="1101" data-end="1143">Optik iletim özellikleri</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1145" data-end="1396">
<thead data-start="1145" data-end="1174">
<tr data-start="1145" data-end="1174">
<th class="" data-start="1145" data-end="1157" data-col-size="sm">Parametre</th>
<th class="" data-start="1157" data-end="1174" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1204" data-end="1396">
<tr data-start="1204" data-end="1236">
<td data-start="1204" data-end="1212" data-col-size="sm">Elyaf</td>
<td data-start="1212" data-end="1236" data-col-size="sm">Tek modlu 9/125 µm</td>
</tr>
<tr data-start="1237" data-end="1258">
<td data-start="1237" data-end="1251" data-col-size="sm">Lehçe tipi</td>
<td data-start="1251" data-end="1258" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1259" data-end="1289">
<td data-start="1259" data-end="1276" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1276" data-end="1289" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1290" data-end="1315">
<td data-start="1290" data-end="1304" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1304" data-end="1315" data-col-size="sm">≥ 50 dB</td>
</tr>
<tr data-start="1316" data-end="1358">
<td data-start="1316" data-end="1340" data-col-size="sm">Çalışma dalga boyları</td>
<td data-start="1340" data-end="1358" data-col-size="sm">1310 / 1550 nm</td>
</tr>
<tr data-start="1359" data-end="1396">
<td data-start="1359" data-end="1379" data-col-size="sm">Çiftleşme dayanıklılığı</td>
<td data-start="1379" data-end="1396" data-col-size="sm">≥ 1000 döngü</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1398" data-end="1496">Bu değerler şunları destekler <strong data-start="1419" data-end="1463">Ethernet, SDH, metro ve erişim ağları</strong> uzun vadeli sinyal kararlılığı ile.</p>
<hr data-start="1498" data-end="1501" />
<h3 data-start="1503" data-end="1528">Çift yönlü LC yapısı</h3>
<p data-start="1530" data-end="1659">İki fiber, bir LC dubleks muhafazanın içine sabitlenerek <strong data-start="1590" data-end="1619">doğru Tx/Rx oryantasyonu</strong> kablolar taşındığında veya bakım yapıldığında bile.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1661" data-end="1899">
<thead data-start="1661" data-end="1687">
<tr data-start="1661" data-end="1687">
<th class="" data-start="1661" data-end="1676" data-col-size="sm">İnşaat</th>
<th class="" data-start="1676" data-end="1687" data-col-size="sm">Fayda</th>
</tr>
</thead>
<tbody data-start="1713" data-end="1899">
<tr data-start="1713" data-end="1765">
<td data-start="1713" data-end="1739" data-col-size="sm">1,25 mm seramik yüksükler</td>
<td data-col-size="sm" data-start="1739" data-end="1765">Hassas çekirdek hizalama</td>
</tr>
<tr data-start="1766" data-end="1809">
<td data-start="1766" data-end="1791" data-col-size="sm">UPC cilalı uç yüzeyler</td>
<td data-col-size="sm" data-start="1791" data-end="1809">Düşük yansıma</td>
</tr>
<tr data-start="1810" data-end="1849">
<td data-start="1810" data-end="1827" data-col-size="sm">Çift yönlü LC klips</td>
<td data-col-size="sm" data-start="1827" data-end="1849">Polariteyi korur</td>
</tr>
<tr data-start="1850" data-end="1899">
<td data-start="1850" data-end="1871" data-col-size="sm">Kalın 3.0mm ceket</td>
<td data-start="1871" data-end="1899" data-col-size="sm">Gerilime karşı korur</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1901" data-end="1904" />
<h3 data-start="1906" data-end="1928">Profesyonel Soru-Cevap</h3>
<p data-start="1930" data-end="2085"><strong data-start="1930" data-end="1978">Ne zaman 2.0mm yerine 3.0mm seçmeliyim?</strong><br data-start="1978" data-end="1981" />Jumper geçtiğinde <strong data-start="2010" data-end="2053">kablo kanalları, yükselticiler veya omurga çerçeveleri</strong> bükülebileceği veya çekilebileceği yerlerde.</p>
<p data-start="2087" data-end="2216"><strong data-start="2087" data-end="2135">Bu tüm LC UPC adaptörleri ile uyumlu mu?</strong><br data-start="2135" data-end="2138" />Evet. LC arayüzü standarttır ve tüm LC UPC panellerine ve alıcı-vericilerine uyar.</p>
<p data-start="2218" data-end="2353"><strong data-start="2218" data-end="2255">Bu PON sistemleri için kullanılabilir mi?</strong><br data-start="2255" data-end="2258" />Evet, ancak RF kaplaması veya yansımaya duyarlı PON sistemleri için, <strong data-start="2319" data-end="2329">LC APC</strong> bunun yerine tavsiye edilir.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-dubleks-tekli%cc%87-mod/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Çift Yönlü Çok Modlu (Göl Mavisi)</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu-gol-mavisi/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu-gol-mavisi/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:59:35 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=882</guid>

					<description><![CDATA[]]></description>
										<content:encoded><![CDATA[]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu-gol-mavisi/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Dubleks Çok Modlu Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:58:35 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=880</guid>

					<description><![CDATA[<p data-start="162" data-end="539">Bu <strong data-start="166" data-end="221">LC UPC 2.0mm Dubleks Çok Modlu Fiber Optik Konnektör</strong> için tasarlanmıştır <strong data-start="238" data-end="296">yüksek bant genişlikli, kısa-orta mesafeli optik bağlantılar</strong> veri merkezlerinin, kurumsal ağların ve endüstriyel kontrol sistemlerinin içinde.<br data-start="369" data-end="372" />Çok modlu fiber şu durumlarda seçilir <strong data-start="404" data-end="444">hız, istikrar ve maliyet verimliliği</strong> aşırı mesafeden daha önemlidir ve bu LC dubleks konektör tam olarak bu dengeyi sağlar.</p>
<p data-start="541" data-end="707">ile <strong data-start="546" data-end="574">UPC cilalı LC yüksükler</strong>, sağlar <strong data-start="587" data-end="636">sıkı fiziksel temas ve düşük ekleme kaybı</strong>, için ideal hale getirir. <strong data-start="658" data-end="706">10G, 40G ve 100G çok modlu optik kanallar</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="714" data-end="772">Çift yönlü çok modlu - çift yönlü veri akışı için üretilmiştir</h3>
<p data-start="774" data-end="963">Çok modlu alıcı-vericiler her zaman <strong data-start="812" data-end="848">iki fiber: gönderme ve alma</strong>.<br data-start="849" data-end="852" />Dubleks LC yapısı onları birbirine kilitli tutarak ters polariteyi önler ve içeride yama yapmayı basitleştirir:</p>
<ul data-start="965" data-end="1053">
<li data-start="965" data-end="981">
<p data-start="967" data-end="981">Sunucu rafları</p>
</li>
<li data-start="982" data-end="999">
<p data-start="984" data-end="999">Çerçeveleri değiştir</p>
</li>
<li data-start="1000" data-end="1020">
<p data-start="1002" data-end="1020">Depolama ağları</p>
</li>
<li data-start="1021" data-end="1053">
<p data-start="1023" data-end="1053">Endüstriyel Ethernet kabinleri</p>
</li>
</ul>
<p data-start="1055" data-end="1144">Yüksek yoğunluklu ortamlarda, LC dupleks şunları sağlar <strong data-start="1102" data-end="1126">bağlantı noktası sayısının iki katı</strong> SC konektörlerinin.</p>
<hr data-start="1146" data-end="1149" />
<h3 data-start="1151" data-end="1193">2.0mm ceket - esnek ama güvenilir</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1195" data-end="1372">
<thead data-start="1195" data-end="1228">
<tr data-start="1195" data-end="1228">
<th class="" data-start="1195" data-end="1208" data-col-size="sm">Kablo boyutu</th>
<th class="" data-start="1208" data-end="1228" data-col-size="sm">Ne sağlıyor</th>
</tr>
</thead>
<tbody data-start="1261" data-end="1372">
<tr data-start="1261" data-end="1290">
<td data-start="1261" data-end="1269" data-col-size="sm">0.9mm</td>
<td data-start="1269" data-end="1290" data-col-size="sm">Ekleme, kırılgan</td>
</tr>
<tr data-start="1291" data-end="1346">
<td data-start="1291" data-end="1303" data-col-size="sm"><strong data-start="1293" data-end="1302">2.0mm</strong></td>
<td data-start="1303" data-end="1346" data-col-size="sm"><strong data-start="1305" data-end="1344">Canlı yama, alıcı-vericiler, paneller</strong></td>
</tr>
<tr data-start="1347" data-end="1372">
<td data-start="1347" data-end="1355" data-col-size="sm">3.0mm</td>
<td data-start="1355" data-end="1372" data-col-size="sm">Ağır yönlendirme</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1374" data-end="1517">2.0mm kablo aşağıdakiler için optimize edilmiştir <strong data-start="1407" data-end="1462">LC portlarının arkasına sık sık takma ve sıkı yönlendirme</strong>, Bu da onu aktif ekipman için endüstri standardı haline getiriyor.</p>
<hr data-start="1519" data-end="1522" />
<h3 data-start="1524" data-end="1559">Çok modlu optik performans</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1561" data-end="1841">
<thead data-start="1561" data-end="1590">
<tr data-start="1561" data-end="1590">
<th class="" data-start="1561" data-end="1573" data-col-size="sm">Parametre</th>
<th class="" data-start="1573" data-end="1590" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1620" data-end="1841">
<tr data-start="1620" data-end="1662">
<td data-start="1620" data-end="1633" data-col-size="sm">Fiber tipi</td>
<td data-start="1633" data-end="1662" data-col-size="sm">OM2 / OM3 / OM4 çok modlu</td>
</tr>
<tr data-start="1663" data-end="1703">
<td data-start="1663" data-end="1675" data-col-size="sm">Çekirdek boyutu</td>
<td data-start="1675" data-end="1703" data-col-size="sm">50/125 µm veya 62,5/125 µm</td>
</tr>
<tr data-start="1704" data-end="1720">
<td data-start="1704" data-end="1713" data-col-size="sm">Lehçe</td>
<td data-start="1713" data-end="1720" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1721" data-end="1751">
<td data-start="1721" data-end="1738" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1738" data-end="1751" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1752" data-end="1777">
<td data-start="1752" data-end="1766" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1766" data-end="1777" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1778" data-end="1809">
<td data-start="1778" data-end="1792" data-col-size="sm">Dalga Boyları</td>
<td data-start="1792" data-end="1809" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1810" data-end="1841">
<td data-start="1810" data-end="1823" data-col-size="sm">Dayanıklılık</td>
<td data-start="1823" data-end="1841" data-col-size="sm">≥ 1000 çiftleşme</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1843" data-end="1929">Bu spesifikasyonlar şunları destekler <strong data-start="1872" data-end="1928">Ethernet, SAN ve kısa erişimli optik ara bağlantılar</strong>.</p>
<hr data-start="1931" data-end="1934" />
<h3 data-start="1936" data-end="1962">Konektörün içinde</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1964" data-end="2216">
<thead data-start="1964" data-end="1988">
<tr data-start="1964" data-end="1988">
<th class="" data-start="1964" data-end="1976" data-col-size="sm">Bileşen</th>
<th class="" data-start="1976" data-end="1988" data-col-size="sm">Fonksiyon</th>
</tr>
</thead>
<tbody data-start="2012" data-end="2216">
<tr data-start="2012" data-end="2064">
<td data-start="2012" data-end="2037" data-col-size="sm">1,25 mm seramik yüksük</td>
<td data-start="2037" data-end="2064" data-col-size="sm">Hassas fiber hizalama</td>
</tr>
<tr data-start="2065" data-end="2119">
<td data-start="2065" data-end="2089" data-col-size="sm">UPC cilalı uç yüzey</td>
<td data-start="2089" data-end="2119" data-col-size="sm">Fresnel yansımasını azaltır</td>
</tr>
<tr data-start="2120" data-end="2161">
<td data-start="2120" data-end="2137" data-col-size="sm">Çift yönlü LC klips</td>
<td data-start="2137" data-end="2161" data-col-size="sm">Tx/Rx'i sırayla tutar</td>
</tr>
<tr data-start="2162" data-end="2216">
<td data-start="2162" data-end="2189" data-col-size="sm">2.0mm gerilim azaltıcı çizme</td>
<td data-start="2189" data-end="2216" data-col-size="sm">Bükülme hasarını önler</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2218" data-end="2221" />
<h3 data-start="2223" data-end="2245">Profesyonel Soru-Cevap</h3>
<p data-start="2247" data-end="2404"><strong data-start="2247" data-end="2297">Çok modlu uzun mesafeli bağlantılar için uygun mudur?</strong><br data-start="2297" data-end="2300" />Hayır. Multimode aşağıdakiler için optimize edilmiştir <strong data-start="2331" data-end="2361">kısa ve orta mesafeler</strong> Binaların ve veri merkezlerinin içi gibi.</p>
<p data-start="2406" data-end="2549"><strong data-start="2406" data-end="2462">Bu LC UPC konektörü APC adaptörleri ile kullanılabilir mi?</strong><br data-start="2462" data-end="2465" />Hayır. UPC ve APC karıştırılmamalıdır - uç yüzeyler farklıdır ve zarar görür.</p>
<p data-start="2551" data-end="2743"><strong data-start="2551" data-end="2595">Neden simpleks yerine LC dupleksi seçmelisiniz?</strong><br data-start="2595" data-end="2598" />Çünkü Ethernet ve optik modüller <strong data-start="2643" data-end="2667">iki yönlü iletim</strong>, ve dubleks konektörler şunları sağlar <strong data-start="2698" data-end="2742">doğru polarite ve daha hızlı kurulum</strong>.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-cok-modlu/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Dubleks Tekli Mod Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-tekli%cc%87-mod/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-tekli%cc%87-mod/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:57:29 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=878</guid>

					<description><![CDATA[<p data-start="175" data-end="539">Modern optik ağlarda, çoğu bağlantı uzun mesafeli değildir - bunlar <strong data-start="243" data-end="284">kısa, sık ve yüksek bağlantılı</strong>.<br data-start="285" data-end="288" />Veri merkezlerinin, merkez ofislerin ve ekipman odalarının içinde fiberler sürekli olarak takılır, çıkarılır ve yeniden düzenlenir.<br data-start="408" data-end="411" />Bu <strong data-start="415" data-end="449">LC UPC 2.0mm Çift Yönlü Tekli Mod</strong> konnektör tam olarak bu tür işlemler için tasarlanmıştır <strong data-start="497" data-end="538">yüksek yoğunluklu, yüksek değişimli ortam</strong>.</p>
<p data-start="541" data-end="758">Onun <strong data-start="545" data-end="563">LC form faktörü</strong> SC konektörlere kıyasla bağlantı noktası yoğunluğunu iki katına çıkarırken <strong data-start="624" data-end="649">UPC cilalı uç yüzey</strong> sağlar <strong data-start="658" data-end="708">düşük ekleme kaybı ve kararlı optik kuplaj</strong> 1310 nm ve 1550 nm tek modlu iletim için.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="765" data-end="832">Çift yönlü yapı - gönderme ve almayı her zaman eşleştirilmiş halde tutmak</h3>
<p data-start="834" data-end="1008">Tek modlu sistemler şunlara bağlıdır <strong data-start="864" data-end="895">hassas çift yönlü yollar</strong>.<br data-start="896" data-end="899" />Dubleks LC muhafazası ile her iki fiber birlikte kilitli kalır ve bağlantı sırasında kutup hatalarını önler:</p>
<ul data-start="1010" data-end="1106">
<li data-start="1010" data-end="1029">
<p data-start="1012" data-end="1029">Anahtar <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> anahtar</p>
</li>
<li data-start="1030" data-end="1049">
<p data-start="1032" data-end="1049">Yönlendirici <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> yönlendirici</p>
</li>
<li data-start="1050" data-end="1078">
<p data-start="1052" data-end="1078">OLT <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> dağıtım çerçevesi</p>
</li>
<li data-start="1079" data-end="1106">
<p data-start="1081" data-end="1106">Sunucu <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> depolama sistemi</p>
</li>
</ul>
<p data-start="1108" data-end="1172">Bakım sırasında bile bağlantı düzenli ve izlenebilir kalır.</p>
<hr data-start="1174" data-end="1177" />
<h3 data-start="1179" data-end="1231">Neden 2.0mm aktif ekipman için standarttır?</h3>
<p data-start="1233" data-end="1319">2.0mm ceket <strong data-start="1257" data-end="1283">endüstri̇ denge noktasi</strong> Esneklik ve koruma arasında.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1321" data-end="1555">
<thead data-start="1321" data-end="1364">
<tr data-start="1321" data-end="1364">
<th class="" data-start="1321" data-end="1335" data-col-size="sm">Ceket bedeni</th>
<th class="" data-start="1335" data-end="1364" data-col-size="md">Gerçek ağlarda davranış</th>
</tr>
</thead>
<tbody data-start="1407" data-end="1555">
<tr data-start="1407" data-end="1448">
<td data-start="1407" data-end="1415" data-col-size="sm">0.9mm</td>
<td data-start="1415" data-end="1448" data-col-size="md">Canlı yama için çok kırılgan</td>
</tr>
<tr data-start="1449" data-end="1512">
<td data-start="1449" data-end="1461" data-col-size="sm"><strong data-start="1451" data-end="1460">2.0mm</strong></td>
<td data-col-size="md" data-start="1461" data-end="1512"><strong data-start="1463" data-end="1510">Anahtarlar, paneller ve alıcı-vericiler için mükemmel</strong></td>
</tr>
<tr data-start="1513" data-end="1555">
<td data-start="1513" data-end="1521" data-col-size="sm">3.0mm</td>
<td data-col-size="md" data-start="1521" data-end="1555">Raf bağlantı noktaları için aşırı mühendislik</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1557" data-end="1664">LC adaptörlerinin arkasında kolayca bükülürken, fiberi mikro bükülme ve kullanım stresinden korur.</p>
<hr data-start="1666" data-end="1669" />
<h3 data-start="1671" data-end="1696">Optik performans</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1698" data-end="1945">
<thead data-start="1698" data-end="1727">
<tr data-start="1698" data-end="1727">
<th class="" data-start="1698" data-end="1710" data-col-size="sm">Parametre</th>
<th class="" data-start="1710" data-end="1727" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1757" data-end="1945">
<tr data-start="1757" data-end="1794">
<td data-start="1757" data-end="1770" data-col-size="sm">Fiber tipi</td>
<td data-start="1770" data-end="1794" data-col-size="sm">Tek modlu 9/125 µm</td>
</tr>
<tr data-start="1795" data-end="1813">
<td data-start="1795" data-end="1806" data-col-size="sm">Uç yüz</td>
<td data-start="1806" data-end="1813" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1814" data-end="1844">
<td data-start="1814" data-end="1831" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1831" data-end="1844" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1845" data-end="1870">
<td data-start="1845" data-end="1859" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1859" data-end="1870" data-col-size="sm">≥ 50 dB</td>
</tr>
<tr data-start="1871" data-end="1913">
<td data-start="1871" data-end="1895" data-col-size="sm">Çalışma dalga boyları</td>
<td data-start="1895" data-end="1913" data-col-size="sm">1310 / 1550 nm</td>
</tr>
<tr data-start="1914" data-end="1945">
<td data-start="1914" data-end="1927" data-col-size="sm">Dayanıklılık</td>
<td data-start="1927" data-end="1945" data-col-size="sm">≥ 1000 çiftleşme</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1947" data-end="2037">Bu değerler şunları destekler <strong data-start="1968" data-end="2011">Ethernet, SDH, DWDM ve erişim ağları</strong> uzun vadeli istikrar ile.</p>
<hr data-start="2039" data-end="2042" />
<h3 data-start="2044" data-end="2082">Konnektör içindeki mühendislik</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2084" data-end="2348">
<thead data-start="2084" data-end="2099">
<tr data-start="2084" data-end="2099">
<th class="" data-start="2084" data-end="2091" data-col-size="sm">Parça</th>
<th class="" data-start="2091" data-end="2099" data-col-size="sm">Rol</th>
</tr>
</thead>
<tbody data-start="2116" data-end="2348">
<tr data-start="2116" data-end="2180">
<td data-start="2116" data-end="2142" data-col-size="sm">1,25 mm zirkonya yüksük</td>
<td data-start="2142" data-end="2180" data-col-size="sm">Elyaf çekirdeğini mükemmel hizada tutar</td>
</tr>
<tr data-start="2181" data-end="2234">
<td data-start="2181" data-end="2204" data-col-size="sm">Hassas UPC cilası</td>
<td data-col-size="sm" data-start="2204" data-end="2234">Fresnel yansımasını azaltır</td>
</tr>
<tr data-start="2235" data-end="2284">
<td data-start="2235" data-end="2253" data-col-size="sm">Çift yönlü LC mandalı</td>
<td data-start="2253" data-end="2284" data-col-size="sm">Tx/Rx yönelimini korur</td>
</tr>
<tr data-start="2285" data-end="2348">
<td data-start="2285" data-end="2312" data-col-size="sm">2.0mm gerilim azaltıcı çizme</td>
<td data-col-size="sm" data-start="2312" data-end="2348">Bükülmeyi ve çekme hasarını önler</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2350" data-end="2353" />
<h3 data-start="2355" data-end="2377">Profesyonel Soru-Cevap</h3>
<p data-start="2379" data-end="2562"><strong data-start="2379" data-end="2445">LC UPC dupleks uzun mesafeli tek modlu bağlantılar için kullanılabilir mi?</strong><br data-start="2445" data-end="2448" />Evet, yaygın olarak <strong data-start="2474" data-end="2515">omurga, metro ve veri merkezi bağlantıları</strong> Düşük kayıp ve kararlı eşleşmenin gerekli olduğu yerlerde.</p>
<p data-start="2564" data-end="2714"><strong data-start="2564" data-end="2604">UPC, APC adaptörleri ile uyumlu mu?</strong><br data-start="2604" data-end="2607" />Hayır. UPC sadece UPC'ye bağlanmalıdır. UPC ve APC'nin karıştırılması yüksüklere zarar verir ve performansı düşürür.</p>
<p data-start="2716" data-end="2886"><strong data-start="2716" data-end="2772">Neden iki simpleks konektör yerine dubleks tercih edilir?</strong><br data-start="2772" data-end="2775" />Dubleks sağlar <strong data-start="2790" data-end="2860">doğru polarite, daha hızlı kurulum ve daha temiz kablo yönetimi</strong> profesyonel ağlarda.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-dubleks-tekli%cc%87-mod/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC APC 3.0mm Çift Yönlü Tekli Mod Fiber Optik Konnektör</title>
		<link>https://www.fenxifiber.com/tr/product/lc-apc-3-0mm-duplex-tekli%cc%87-mod/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-apc-3-0mm-duplex-tekli%cc%87-mod/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:56:27 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=875</guid>

					<description><![CDATA[<p data-start="94" data-end="426">Uzun mesafeli tek modlu bağlantılar sadece düşük kayıpla ilgili değildir - aynı zamanda <strong data-start="171" data-end="194">mekanik hayatta kalma</strong>.<br data-start="195" data-end="198" />Omurga odalarında, ODF çerçevelerinde, dış mekan dolaplarında ve koridor kanallarında, fiber atlama telleri tekrar tekrar bükülür, çekilir ve yeniden yönlendirilir.<br data-start="328" data-end="331" />Bu <strong data-start="335" data-end="379">LC APC 3.0mm Çift Yönlü Tekli Mod konektör</strong> tam da bu tür ortamlar için üretilmiştir.</p>
<p data-start="428" data-end="633">Bu birleştirir <strong data-start="440" data-end="464">APC açılı parlatma</strong> ile optik kararlılık için <strong data-start="494" data-end="521">3.0mm ağır hizmet ceketi</strong> karşı koruyan <strong data-start="554" data-end="593">gerilim, ezilme ve mikro bükülme</strong>, zorlu kurulum koşullarında bile.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="640" data-end="717">3.0mm kılıf - kablonun kendisi sistem güvenilirliğinin bir parçası haline geldiğinde</h3>
<p data-start="719" data-end="903">3,0 mm dubleks jumper sadece “daha kalın” değildir.<br data-start="765" data-end="768" />Bu bir <strong data-start="778" data-end="843">daha güçlü aramid iplik katmanı, daha büyük tampon ve güçlendirilmiş çizme</strong>, Bu da mekanik güvenlik marjını önemli ölçüde artırır.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="905" data-end="1092">
<thead data-start="905" data-end="941">
<tr data-start="905" data-end="941">
<th class="" data-start="905" data-end="919" data-col-size="sm">Ceket bedeni</th>
<th class="" data-start="919" data-end="941" data-col-size="md">Gerçek dünya anlamı</th>
</tr>
</thead>
<tbody data-start="976" data-end="1092">
<tr data-start="976" data-end="1021">
<td data-start="976" data-end="984" data-col-size="sm">2.0mm</td>
<td data-col-size="md" data-start="984" data-end="1021">Raftan rafa ve cihaz bağlantı noktaları için</td>
</tr>
<tr data-start="1022" data-end="1092">
<td data-start="1022" data-end="1034" data-col-size="sm"><strong data-start="1024" data-end="1033">3.0mm</strong></td>
<td data-col-size="md" data-start="1034" data-end="1092"><strong data-start="1036" data-end="1090">Omurga yönlendirmesi, zemin kanalları, kabin atlama telleri için</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1094" data-end="1219">Bu, 3.0mm dubleks APC LC'yi özellikle aşağıdakiler için uygun hale getirir <strong data-start="1153" data-end="1218">metro fiber odaları, CATV merkezleri ve telekom dağıtım çerçeveleri</strong>.</p>
<hr data-start="1221" data-end="1224" />
<h3 data-start="1226" data-end="1276">Yansıma açısından kritik sistemler için APC geometrisi</h3>
<p data-start="1278" data-end="1363">Açılı fiziksel temas, yansıyan ışığın fiber çekirdeğe yeniden girmesini önler.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1365" data-end="1639">
<thead data-start="1365" data-end="1404">
<tr data-start="1365" data-end="1404">
<th class="" data-start="1365" data-end="1387" data-col-size="sm">Optik performans</th>
<th class="" data-start="1387" data-end="1404" data-col-size="sm">Tipik değer</th>
</tr>
</thead>
<tbody data-start="1443" data-end="1639">
<tr data-start="1443" data-end="1480">
<td data-start="1443" data-end="1456" data-col-size="sm">Fiber tipi</td>
<td data-start="1456" data-end="1480" data-col-size="sm">Tek modlu 9/125 µm</td>
</tr>
<tr data-start="1481" data-end="1502">
<td data-start="1481" data-end="1490" data-col-size="sm">Lehçe</td>
<td data-start="1490" data-end="1502" data-col-size="sm">APC (8°)</td>
</tr>
<tr data-start="1503" data-end="1533">
<td data-start="1503" data-end="1520" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1520" data-end="1533" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1534" data-end="1559">
<td data-start="1534" data-end="1548" data-col-size="sm">Geri dönüş kaybı</td>
<td data-col-size="sm" data-start="1548" data-end="1559">≥ 60 dB</td>
</tr>
<tr data-start="1560" data-end="1607">
<td data-start="1560" data-end="1582" data-col-size="sm">Çalışma dalga boyları</td>
<td data-col-size="sm" data-start="1582" data-end="1607">1310 / 1490 / 1550 nm</td>
</tr>
<tr data-start="1608" data-end="1639">
<td data-start="1608" data-end="1621" data-col-size="sm">Dayanıklılık</td>
<td data-col-size="sm" data-start="1621" data-end="1639">≥ 1000 çiftleşme</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1641" data-end="1736">Bu yansıma kontrolü aşağıdakiler için gereklidir <strong data-start="1682" data-end="1735">RFoG, CATV overlay, GPON ve uzun mesafeli DWDM bağlantıları</strong>.</p>
<hr data-start="1738" data-end="1741" />
<h3 data-start="1743" data-end="1801">Gerçek çift yönlü iletim için çift yönlü yapı</h3>
<p data-start="1803" data-end="1882">Dubleks LC formatı, iki fiberi tek bir konektör gövdesinde birbirine kilitleyerek</p>
<ul data-start="1884" data-end="1968">
<li data-start="1884" data-end="1910">
<p data-start="1886" data-end="1910">Kararlı Tx/Rx hizalaması</p>
</li>
<li data-start="1911" data-end="1934">
<p data-start="1913" data-end="1934">Daha hızlı kurulum</p>
</li>
<li data-start="1935" data-end="1968">
<p data-start="1937" data-end="1968">Daha düşük polarite hatası riski</p>
</li>
</ul>
<p data-start="1970" data-end="2092">Kablolar yoğun bir şekilde kablo kanallarından geçirilse bile, <strong data-start="2027" data-end="2091">dubleks APC LC her iki kanalı da korumalı ve senkronize tutar</strong>.</p>
<hr data-start="2094" data-end="2097" />
<h3 data-start="2099" data-end="2124">Mühendislik detayları</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2126" data-end="2399">
<thead data-start="2126" data-end="2150">
<tr data-start="2126" data-end="2150">
<th class="" data-start="2126" data-end="2138" data-col-size="sm">Bileşen</th>
<th class="" data-start="2138" data-end="2150" data-col-size="sm">Fonksiyon</th>
</tr>
</thead>
<tbody data-start="2174" data-end="2399">
<tr data-start="2174" data-end="2234">
<td data-start="2174" data-end="2204" data-col-size="sm">1,25 mm zirkonya APC yüksük</td>
<td data-col-size="sm" data-start="2204" data-end="2234">Hassas 8° açıyı korur</td>
</tr>
<tr data-start="2235" data-end="2290">
<td data-start="2235" data-end="2260" data-col-size="sm">Güçlendirilmiş dubleks klips</td>
<td data-col-size="sm" data-start="2260" data-end="2290">Her iki elyafı da sıkıca tutar</td>
</tr>
<tr data-start="2291" data-end="2337">
<td data-start="2291" data-end="2312" data-col-size="sm">Kalın 3.0mm ceket</td>
<td data-col-size="sm" data-start="2312" data-end="2337">Çekme kuvvetini emer</td>
</tr>
<tr data-start="2338" data-end="2399">
<td data-start="2338" data-end="2361" data-col-size="sm">Uzun ömürlü APC cilası</td>
<td data-col-size="sm" data-start="2361" data-end="2399">Geri dönüş kaybını zaman içinde sabit tutar</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2401" data-end="2404" />
<h3 data-start="2406" data-end="2428">Profesyonel Soru-Cevap</h3>
<p data-start="2430" data-end="2574"><strong data-start="2430" data-end="2469">LC adaptörleri için 3,0 mm çok mu kalın?</strong><br data-start="2469" data-end="2472" />Hayır. Sadece kablo daha kalındır. LC yüksük ve muhafaza standart olarak kalır ve tüm LC APC adaptörlerine uyar.</p>
<p data-start="2576" data-end="2733"><strong data-start="2576" data-end="2624">Ne zaman 2.0mm yerine 3.0mm seçmeliyim?</strong><br data-start="2624" data-end="2627" />Yama kabloları olduğunda <strong data-start="2648" data-end="2699">kanallar, dolaplar veya ortak tepsiler aracılığıyla yönlendirilir</strong> bükülebilecekleri veya çekilebilecekleri bir yerde.</p>
<p data-start="2735" data-end="2914"><strong data-start="2735" data-end="2781">APC omurga bağlantıları için gerçekten önemli mi?</strong><br data-start="2781" data-end="2784" />Evet. Bölücüler, amplifikatörler veya RF sinyalleri içeren uzun tek modlu yollarda, <strong data-start="2857" data-end="2891">yansımalar hızla birikir</strong> ve APC bunu engeller.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-apc-3-0mm-duplex-tekli%cc%87-mod/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC APC 2.0mm Çift Yönlü Tekli Mod</title>
		<link>https://www.fenxifiber.com/tr/product/lc-apc-2-0mm-dubleks-tekli%cc%87-mod/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-apc-2-0mm-dubleks-tekli%cc%87-mod/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:55:05 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=873</guid>

					<description><![CDATA[<p data-start="99" data-end="420">PON ve uzun mesafeli tek modlu ağlarda en büyük gizli düşman kayıp değildir - bu <strong data-start="191" data-end="205">yansıma</strong>.<br data-start="206" data-end="209" />Yansıyan her sinyal, yukarı akış lazerlerine müdahale eden gürültü yaratır, özellikle de <strong data-start="298" data-end="340">GPON, XG-PON ve RF-over-fiber sistemleri</strong>.<br data-start="341" data-end="344" />İşte tam da bu yüzden <strong data-start="368" data-end="412">LC APC 2.0mm Çift Yönlü Tekli Mod konektör</strong> var.</p>
<p data-start="422" data-end="724">Kullanarak <strong data-start="434" data-end="476">8 derece açılı fiziksel temas (APC)</strong> Her iki LC yüksüğünde de, bu dubleks konektör yansıyan ışığı vericiye geri göndermek yerine fiber çekirdeğinden dışarı iter. Sonuç olarak <strong data-start="628" data-end="660">çok daha temiz optik kanal</strong>, Birden fazla ayırıcı ve uzun fiber hatları söz konusu olduğunda bile.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="731" data-end="777">Gerçek iki yönlü iletim için Duplex APC</h3>
<p data-start="779" data-end="893">Tek yönlü atlama tellerinin aksine, çift yönlü LC konektörler <strong data-start="829" data-end="868">Tx ve Rx fiberleri kalıcı olarak eşleştirildi</strong>, için gerekli olan:</p>
<ul data-start="895" data-end="988">
<li data-start="895" data-end="920">
<p data-start="897" data-end="920">OLT <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> ONU bağlantıları</p>
</li>
<li data-start="921" data-end="953">
<p data-start="923" data-end="953">Raflar arasındaki omurga bağlantıları</p>
</li>
<li data-start="954" data-end="988">
<p data-start="956" data-end="988">Aktif optik ekipman bağlantı noktaları</p>
</li>
</ul>
<p data-start="990" data-end="1088">Yüksek yoğunluklu panellerde, çift yönlü APC atlama telleri de polarite hatalarını azaltır ve bakımı hızlandırır.</p>
<hr data-start="1090" data-end="1093" />
<h3 data-start="1095" data-end="1141">2.0mm - canlı ağlar için doğru boyut</h3>
<p data-start="1143" data-end="1435">Bir PON veya omurga jumper'ı sürekli olarak ele alınmaktadır.<br data-start="1196" data-end="1199" />OLT kartlarına takılır, kablo yöneticileri aracılığıyla yönlendirilir ve bazen test için çıkarılır.<br data-start="1294" data-end="1297" />Bu nedenle bu model bir <strong data-start="1327" data-end="1374">0,9 mm pigtail fiber yerine 2,0 mm ceket</strong> - şunları sağlar <strong data-start="1389" data-end="1434">sertleşmeden gerçek gerilim azaltma</strong>.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1437" data-end="1632">
<thead data-start="1437" data-end="1473">
<tr data-start="1437" data-end="1473">
<th class="" data-start="1437" data-end="1450" data-col-size="sm">Kablo boyutu</th>
<th class="" data-start="1450" data-end="1473" data-col-size="sm">Ne işe yarar</th>
</tr>
</thead>
<tbody data-start="1508" data-end="1632">
<tr data-start="1508" data-end="1541">
<td data-start="1508" data-end="1516" data-col-size="sm">0.9mm</td>
<td data-start="1516" data-end="1541" data-col-size="sm">Tepsilerin içine ekleme</td>
</tr>
<tr data-start="1542" data-end="1593">
<td data-start="1542" data-end="1554" data-col-size="sm"><strong data-start="1544" data-end="1553">2.0mm</strong></td>
<td data-start="1554" data-end="1593" data-col-size="sm"><strong data-start="1556" data-end="1591">Canlı yama ve ekipman portları</strong></td>
</tr>
<tr data-start="1594" data-end="1632">
<td data-start="1594" data-end="1602" data-col-size="sm">3.0mm</td>
<td data-start="1602" data-end="1632" data-col-size="sm">Dış mekan ve ağır hizmet bağlantıları</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1634" data-end="1637" />
<h3 data-start="1639" data-end="1687">PON ağlarının gerektirdiği optik davranış</h3>
<p data-start="1689" data-end="1766">APC parlatma, UPC ile karşılaştırıldığında yansıma performansını önemli ölçüde artırır.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1768" data-end="2050">
<thead data-start="1768" data-end="1810">
<tr data-start="1768" data-end="1810">
<th class="" data-start="1768" data-end="1793" data-col-size="sm">Optik karakteristik</th>
<th class="" data-start="1793" data-end="1810" data-col-size="sm">Tipik seviye</th>
</tr>
</thead>
<tbody data-start="1853" data-end="2050">
<tr data-start="1853" data-end="1885">
<td data-start="1853" data-end="1861" data-col-size="sm">Elyaf</td>
<td data-start="1861" data-end="1885" data-col-size="sm">Tek modlu 9/125 µm</td>
</tr>
<tr data-start="1886" data-end="1916">
<td data-start="1886" data-end="1897" data-col-size="sm">Uç yüz</td>
<td data-start="1897" data-end="1916" data-col-size="sm">APC (8° açılı)</td>
</tr>
<tr data-start="1917" data-end="1947">
<td data-start="1917" data-end="1934" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1934" data-end="1947" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1948" data-end="1973">
<td data-start="1948" data-end="1962" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1962" data-end="1973" data-col-size="sm">≥ 60 dB</td>
</tr>
<tr data-start="1974" data-end="2023">
<td data-start="1974" data-end="1998" data-col-size="sm">Çalışma dalga boyları</td>
<td data-start="1998" data-end="2023" data-col-size="sm">1310 / 1490 / 1550 nm</td>
</tr>
<tr data-start="2024" data-end="2050">
<td data-start="2024" data-end="2040" data-col-size="sm">Çiftleşme döngüleri</td>
<td data-start="2040" data-end="2050" data-col-size="sm">≥ 1000</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2052" data-end="2154">Bu getiri-zarar seviyesi aşağıdakiler için kritik öneme sahiptir <strong data-start="2091" data-end="2153">GPON, XG-PON, CATV overlay ve uzun mesafeli tek modlu bağlantılar</strong>.</p>
<hr data-start="2156" data-end="2159" />
<h3 data-start="2161" data-end="2200">Yoğun telekom çerçeveleri için tasarlanmıştır</h3>
<p data-start="2202" data-end="2354">APC geometrisi ile bile, konektör hala <strong data-start="2255" data-end="2276">kompakt LC formatı</strong>, izin vermek <strong data-start="2287" data-end="2313">bağlantı noktası yoğunluğunun iki katı</strong> SC konektörlerinin aynı raf alanında.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2356" data-end="2672">
<thead data-start="2356" data-end="2394">
<tr data-start="2356" data-end="2394">
<th class="" data-start="2356" data-end="2378" data-col-size="sm">İnşaat detayı</th>
<th class="" data-start="2378" data-end="2394" data-col-size="sm">Ne işe yarar</th>
</tr>
</thead>
<tbody data-start="2432" data-end="2672">
<tr data-start="2432" data-end="2492">
<td data-start="2432" data-end="2450" data-col-size="sm">LC dubleks mandalı</td>
<td data-start="2450" data-end="2492" data-col-size="sm">Her iki fiberi doğru hizalamada kilitler</td>
</tr>
<tr data-start="2493" data-end="2550">
<td data-start="2493" data-end="2519" data-col-size="sm">1,25 mm seramik yüksükler</td>
<td data-start="2519" data-end="2550" data-col-size="sm">APC açı doğruluğunu koruyun</td>
</tr>
<tr data-start="2551" data-end="2607">
<td data-start="2551" data-end="2576" data-col-size="sm">Güçlendirilmiş 2.0mm botlar</td>
<td data-start="2576" data-end="2607" data-col-size="sm">Elyafın mikro bükülmesini önleyin</td>
</tr>
<tr data-start="2608" data-end="2672">
<td data-start="2608" data-end="2634" data-col-size="sm">Hassas APC parlatma</td>
<td data-start="2634" data-end="2672" data-col-size="sm">Yansımaları lazerin dışında tutar</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="2674" data-end="2677" />
<h3 data-start="2679" data-end="2701">Profesyonel Soru-Cevap</h3>
<p data-start="2703" data-end="2871"><strong data-start="2703" data-end="2743">LC APC dubleks LC UPC'ye bağlanabilir mi?</strong><br data-start="2743" data-end="2746" />Hayır. APC ve UPC konnektörleri asla eşleştirilmemelidir. Açılı APC uç yüzü hasar görecek ve yansıma keskin bir şekilde artacaktır.</p>
<p data-start="2873" data-end="3012"><strong data-start="2873" data-end="2905">PON için dubleks gerekli mi?</strong><br data-start="2905" data-end="2908" />Evet. OLT ve ONU bağlantı noktaları şunları gerektirir <strong data-start="2939" data-end="2963">iki yönlü iletim</strong>, ve dubleks LC, Tx ve Rx'in doğru şekilde eşleşmesini sağlar.</p>
<p data-start="3014" data-end="3227"><strong data-start="3014" data-end="3056">PON bağlantı kabloları için neden 3.0mm kullanılmıyor?</strong><br data-start="3056" data-end="3059" />3.0mm, kablolar ağır çekmeye maruz kaldığında kullanılır. İçin <strong data-start="3119" data-end="3159">raflar, OLT rafları ve iç mekan çerçeveleri</strong>, 2.0mm en iyi dengeyi sağlar <strong data-start="3196" data-end="3226">esneklik ve koruma</strong>.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-apc-2-0mm-dubleks-tekli%cc%87-mod/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 3.0mm Çift Yönlü Çok Modlu Konektör (Gül Kırmızısı)</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-duplex-multimode-gul-kirmizi/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-duplex-multimode-gul-kirmizi/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:53:50 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=871</guid>

					<description><![CDATA[<p data-start="235" data-end="521">Yoğun veri merkezi sıralarında ve endüstriyel raflarda, fiber atlama tellerine nazik davranılmaz.<br data-start="319" data-end="322" />Çekilir, kablo yöneticilerinin etrafında bükülür, yükseltmeler için fişten çıkarılır ve tekrar takılırlar.<br data-start="417" data-end="420" />İşte tam da bu noktada <strong data-start="446" data-end="490">LC UPC 3.0mm Çift Yönlü Çok Modlu (Gül Kırmızısı)</strong> konektör çalışmak üzere tasarlanmıştır.</p>
<p data-start="523" data-end="776">Bu modelde ince bir ofis ceketi yerine <strong data-start="580" data-end="630">uzun gerilim azaltıcı çizmeli tam 3.0mm kablo</strong>, Bu sayede fiber, sinyal kalitesini düşüren mikro bükülmeler oluşturmadan yüksek trafikli ortamlarda hayatta kalmak için ihtiyaç duyduğu fiziksel korumayı sağlar.</p>
<p data-start="778" data-end="956">Aynı zamanda <strong data-start="800" data-end="820">LC dubleks formatı</strong> İletim ve alım fiberlerini birbirine kilitli tutar, doğru polariteyi korur ve yoğun patch panellerdeki kurulum hatalarını azaltır.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="963" data-end="1009">Gül kırmızısı gövde aslında ne anlama geliyor?</h3>
<p data-start="1011" data-end="1245">Modern optik kablolamada renk artık bir dekorasyon değil, bir çalışma aracıdır.<br data-start="1091" data-end="1094" />Bu <strong data-start="1098" data-end="1115">gül kırmızısı gövde</strong> bu konektörün aşağıdakiler için tasarlandığını belirtir <strong data-start="1164" data-end="1198">yüksek bant genişlikli çok modlu fiber</strong>, tipik olarak <strong data-start="1210" data-end="1224">OM4 veya OM5</strong>, için kullanılır:</p>
<ul data-start="1247" data-end="1343">
<li data-start="1247" data-end="1272">
<p data-start="1249" data-end="1272">40G ve 100G Ethernet</p>
</li>
<li data-start="1273" data-end="1312">
<p data-start="1275" data-end="1312">Yüksek hızlı SAN ve depolama ağları</p>
</li>
<li data-start="1313" data-end="1343">
<p data-start="1315" data-end="1343">Veri merkezi omurga bağlantıları</p>
</li>
</ul>
<p data-start="1345" data-end="1473">Teknisyenler, aqua (OM3) ve sarı (tek modlu) kablolar da içeren karışık raflarda bu atlama tellerini hemen tanıyabilir.</p>
<hr data-start="1475" data-end="1478" />
<h3 data-start="1480" data-end="1518">Güvenebileceğiniz optik davranış</h3>
<p data-start="1520" data-end="1814">Ağır 3.0mm kılıfla bile, konektör hala bir <strong data-start="1581" data-end="1626">hassas 1,25 mm zirkonya seramik yüksük</strong> ve bir <strong data-start="1633" data-end="1658">UPC cilalı uç yüzey</strong>.<br data-start="1659" data-end="1662" />Bu kombinasyon şunları sağlar <strong data-start="1688" data-end="1715">istikrarlı fiziksel temas</strong> Çok yüksek veri hızlarında çalışan kısa erişimli çok modlu bağlantılar için kritik olan fiberler arasında.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1816" data-end="2087">
<thead data-start="1816" data-end="1852">
<tr data-start="1816" data-end="1852">
<th class="" data-start="1816" data-end="1835" data-col-size="sm">Performans öğesi</th>
<th class="" data-start="1835" data-end="1852" data-col-size="sm">Tipik seviye</th>
</tr>
</thead>
<tbody data-start="1890" data-end="2087">
<tr data-start="1890" data-end="1934">
<td data-start="1890" data-end="1903" data-col-size="sm">Fiber tipi</td>
<td data-start="1903" data-end="1934" data-col-size="sm">OM3 / OM4 / OM5 (50/125 µm)</td>
</tr>
<tr data-start="1935" data-end="1951">
<td data-start="1935" data-end="1944" data-col-size="sm">Lehçe</td>
<td data-start="1944" data-end="1951" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1952" data-end="1982">
<td data-start="1952" data-end="1969" data-col-size="sm">Ekleme kaybı</td>
<td data-start="1969" data-end="1982" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1983" data-end="2008">
<td data-start="1983" data-end="1997" data-col-size="sm">Geri dönüş kaybı</td>
<td data-start="1997" data-end="2008" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="2009" data-end="2050">
<td data-start="2009" data-end="2031" data-col-size="sm">Çalışma dalga boyları</td>
<td data-start="2031" data-end="2050" data-col-size="sm">850 nm, 1300 nm</td>
</tr>
<tr data-start="2051" data-end="2087">
<td data-start="2051" data-end="2070" data-col-size="sm">Tak-çıkar yaşam</td>
<td data-start="2070" data-end="2087" data-col-size="sm">≥ 1000 döngü</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2089" data-end="2179">Bu değerler, aşağıdakiler için gereken sınırlar dahilindedir <strong data-start="2142" data-end="2178">10G, 25G, 40G ve 100G SR optikler</strong>.</p>
<hr data-start="2181" data-end="2184" />
<h3 data-start="2186" data-end="2233">Laboratuvar kablosu gibi değil, saha jumper'ı gibi üretilmiştir</h3>
<p data-start="2235" data-end="2328">2.0mm dubleks kablo esnekliğe odaklanırken <strong data-start="2290" data-end="2327">3.0mm versiyonu hayatta kalmaya odaklanır</strong>.</p>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="2330" data-end="2653">
<thead data-start="2330" data-end="2369">
<tr data-start="2330" data-end="2369">
<th class="" data-start="2330" data-end="2353" data-col-size="sm">Yapı elemanı</th>
<th class="" data-start="2353" data-end="2369" data-col-size="md">Ne işe yarar</th>
</tr>
</thead>
<tbody data-start="2408" data-end="2653">
<tr data-start="2408" data-end="2461">
<td data-start="2408" data-end="2429" data-col-size="sm">3.0mm dış kılıf</td>
<td data-col-size="md" data-start="2429" data-end="2461">Ezilmeye ve çekilmeye karşı dayanıklıdır</td>
</tr>
<tr data-start="2462" data-end="2527">
<td data-start="2462" data-end="2482" data-col-size="sm">Uzun dubleks botlar</td>
<td data-start="2482" data-end="2527" data-col-size="md">Stresi elyafa ulaşmadan önce absorbe eder</td>
</tr>
<tr data-start="2528" data-end="2594">
<td data-start="2528" data-end="2549" data-col-size="sm">LC itme-çekme mandalı</td>
<td data-start="2549" data-end="2594" data-col-size="md">Kalabalık panellerde konektörleri güvende tutar</td>
</tr>
<tr data-start="2595" data-end="2653">
<td data-start="2595" data-end="2614" data-col-size="sm">Seramik yüksükler</td>
<td data-start="2614" data-end="2653" data-col-size="md">Zaman içinde sabit hizalamayı koruyun</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2655" data-end="2819">Bu, konektörü özellikle aşağıdakiler için uygun hale getirir <strong data-start="2704" data-end="2781">çekirdek raflar, toplama kabinleri, endüstriyel muhafazalar ve telekom odaları</strong>, kabloların sıkça kullanıldığı yerlerde.</p>
<hr data-start="2821" data-end="2824" />
<h3 data-start="2826" data-end="2848">Profesyonel Soru-Cevap</h3>
<p data-start="2850" data-end="3038"><strong data-start="2850" data-end="2894">Bu aqua OM3 jumperlar ile karıştırılabilir mi?</strong><br data-start="2894" data-end="2897" />Evet. Konektör OM3, OM4 ve OM5 çok modlu fiber ile tamamen uyumludur. Gül kırmızısı renk sadece şunu gösterir <strong data-start="3011" data-end="3037">yüksek dereceli çok modlu</strong>.</p>
<p data-start="3040" data-end="3244"><strong data-start="3040" data-end="3078">İç mekanlarda 3.0mm gerçekten gerekli mi?</strong><br data-start="3078" data-end="3081" />Sessiz raflarda 2,0 mm yeterlidir. İçinde <strong data-start="3115" data-end="3179">yoğun veri merkezi sıraları, endüstriyel dolaplar veya telekom çerçeveleri</strong>, 3.0mm kablo hasarını ve sinyal kararsızlığını önemli ölçüde azaltır.</p>
<p data-start="3246" data-end="3415"><strong data-start="3246" data-end="3297">LC UPC, MPO-LC koparma kabloları ile kullanılabilir mi?</strong><br data-start="3297" data-end="3300" />Evet. Bu konektör genellikle LC ucunda kullanılır <strong data-start="3354" data-end="3383">MPO-LC fan çıkışı tertibatları</strong> yüksek hızlı çok modlu bağlantılar için.</p>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-3-0mm-duplex-multimode-gul-kirmizi/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>LC UPC 2.0mm Çift Yönlü Çok Modlu Konektör (Gül Kırmızısı)</title>
		<link>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-duplex-multimode-gul-kirmizi/</link>
					<comments>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-duplex-multimode-gul-kirmizi/#respond</comments>
		
		<dc:creator><![CDATA[Fenxi]]></dc:creator>
		<pubDate>Wed, 04 Feb 2026 02:52:43 +0000</pubDate>
				<guid ispermalink="false">https://www.fenxifiber.com/?post_type=product&#038;p=868</guid>

					<description><![CDATA[<h3 data-start="80" data-end="122">Açıkça tanımlanmış yüksek hızlı bağlantılar</h3>
<p data-start="124" data-end="488">Bu <strong data-start="128" data-end="172">LC UPC 2.0mm Çift Yönlü Çok Modlu (Gül Kırmızısı)</strong> konektör aşağıdakiler için üretilmiştir <strong data-start="196" data-end="258">modern, yüksek bant genişliğine sahip veri merkezi ve kurumsal ağlar</strong>.<br data-start="259" data-end="262" />Onun <strong data-start="266" data-end="286">dubleks LC tasarımı</strong> taşır <strong data-start="295" data-end="338">Tek, kompakt bir mandalda Tx/Rx fiberleri</strong>, ve <strong data-start="350" data-end="370">gül kırmızısı gövde</strong> anında sinyaller <strong data-start="389" data-end="425">yüksek dereceli çok modlu (OM4 / OM5)</strong>-Renk kodlamasının maliyetli hataları önlediği raflar için mükemmeldir.</p>
<p data-start="490" data-end="698">ile <strong data-start="495" data-end="536">UPC ile parlatılmış 1,25 mm seramik yüksükler</strong> ve bir <strong data-start="543" data-end="568">dayanıklı 2.0 mm ceket</strong>, bu konektör şunları sağlar <strong data-start="594" data-end="624">istikrarlı optik performans</strong> ve <strong data-start="629" data-end="659">günlük yama güvenilirliği</strong> için <strong data-start="664" data-end="697">10G ila 100G kısa erişimli bağlantılar</strong>.</p>]]></description>
										<content:encoded><![CDATA[<h3 data-start="705" data-end="752">Dubleks LC neden veri merkezi standardıdır?</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="754" data-end="948">
<thead data-start="754" data-end="808">
<tr data-start="754" data-end="808">
<th class="" data-start="754" data-end="771" data-col-size="sm">Konektör Tipi</th>
<th class="" data-start="771" data-end="789" data-col-size="sm">Ne taşıyor</th>
<th class="" data-start="789" data-end="808" data-col-size="sm">Kullanıldığı yerler</th>
</tr>
</thead>
<tbody data-start="823" data-end="948">
<tr data-start="823" data-end="866">
<td data-start="823" data-end="833" data-col-size="sm">Simplex</td>
<td data-start="833" data-end="845" data-col-size="sm">Bir fiber</td>
<td data-start="845" data-end="866" data-col-size="sm">Pigtailler, test</td>
</tr>
<tr data-start="867" data-end="948">
<td data-start="867" data-end="883" data-col-size="sm"><strong data-start="869" data-end="882">Çift Yönlü LC</strong></td>
<td data-start="883" data-end="908" data-col-size="sm"><strong data-start="885" data-end="907">İki fiber (Tx/Rx)</strong></td>
<td data-start="908" data-end="948" data-col-size="sm"><strong data-start="910" data-end="946">Anahtar <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Sunucu, Anahtar <img src="https://s.w.org/images/core/emoji/17.0.2/72x72/2194.png" alt="↔" class="wp-smiley" style="height: 1em; max-height: 1em;" /> Anahtar</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="950" data-end="1047">Tek bir dubleks fiş, iki tek yönlü kablonun yerini alır-<strong data-start="998" data-end="1046">daha hızlı kurulum, daha az hata, daha temiz raflar</strong>.</p>
<hr data-start="1049" data-end="1052" />
<h3 data-start="1054" data-end="1095">Rose-red = yüksek bant genişlikli çok modlu</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1097" data-end="1280">
<thead data-start="1097" data-end="1143">
<tr data-start="1097" data-end="1143">
<th class="" data-start="1097" data-end="1111" data-col-size="sm">Elyaf Sınıfı</th>
<th class="" data-start="1111" data-end="1119" data-col-size="sm">Renk</th>
<th class="" data-start="1119" data-end="1143" data-col-size="sm">100G'de Tipik Erişim</th>
</tr>
</thead>
<tbody data-start="1158" data-end="1280">
<tr data-start="1158" data-end="1180">
<td data-start="1158" data-end="1164" data-col-size="sm">OM3</td>
<td data-start="1164" data-end="1171" data-col-size="sm">Aqua</td>
<td data-start="1171" data-end="1180" data-col-size="sm">~70 m</td>
</tr>
<tr data-start="1181" data-end="1229">
<td data-start="1181" data-end="1191" data-col-size="sm"><strong data-start="1183" data-end="1190">OM4</strong></td>
<td data-start="1191" data-end="1215" data-col-size="sm"><strong data-start="1193" data-end="1214">Gül kırmızısı / Menekşe</strong></td>
<td data-start="1215" data-end="1229" data-col-size="sm"><strong data-start="1217" data-end="1227">~100 m</strong></td>
</tr>
<tr data-start="1230" data-end="1280">
<td data-start="1230" data-end="1240" data-col-size="sm"><strong data-start="1232" data-end="1239">OM5</strong></td>
<td data-start="1240" data-end="1262" data-col-size="sm"><strong data-start="1242" data-end="1261">Gül Kırmızısı / Misket Limonu</strong></td>
<td data-start="1262" data-end="1280" data-col-size="sm"><strong data-start="1264" data-end="1278">SWDM'ye hazır</strong></td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="1282" data-end="1387">Gül kırmızısı konektörlerin kullanılması teknisyenlere yardımcı olur <strong data-start="1326" data-end="1358">OM4/OM5 yollarını anında tespit edin</strong> karışık fiber ortamlarda.</p>
<hr data-start="1389" data-end="1392" />
<h3 data-start="1394" data-end="1429">Optik performans (çok modlu)</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1431" data-end="1701">
<thead data-start="1431" data-end="1460">
<tr data-start="1431" data-end="1460">
<th class="" data-start="1431" data-end="1443" data-col-size="sm">Parametre</th>
<th class="" data-start="1443" data-end="1460" data-col-size="sm">Tipik Değer</th>
</tr>
</thead>
<tbody data-start="1471" data-end="1701">
<tr data-start="1471" data-end="1515">
<td data-start="1471" data-end="1484" data-col-size="sm">Elyaf Tipi</td>
<td data-start="1484" data-end="1515" data-col-size="sm">OM3 / OM4 / OM5 (50/125 µm)</td>
</tr>
<tr data-start="1516" data-end="1532">
<td data-start="1516" data-end="1525" data-col-size="sm">Lehçe</td>
<td data-start="1525" data-end="1532" data-col-size="sm">UPC</td>
</tr>
<tr data-start="1533" data-end="1563">
<td data-start="1533" data-end="1550" data-col-size="sm">Ekleme Kaybı</td>
<td data-start="1550" data-end="1563" data-col-size="sm">≤ 0,30 dB</td>
</tr>
<tr data-start="1564" data-end="1589">
<td data-start="1564" data-end="1578" data-col-size="sm">Geri Dönüş Kaybı</td>
<td data-start="1578" data-end="1589" data-col-size="sm">≥ 35 dB</td>
</tr>
<tr data-start="1590" data-end="1621">
<td data-start="1590" data-end="1604" data-col-size="sm">Dalga Boyları</td>
<td data-start="1604" data-end="1621" data-col-size="sm">850 / 1300 nm</td>
</tr>
<tr data-start="1622" data-end="1669">
<td data-start="1622" data-end="1641" data-col-size="sm">Desteklenen Hızlar</td>
<td data-col-size="sm" data-start="1641" data-end="1669">10G, 25G, 40G, 100G (SR)</td>
</tr>
<tr data-start="1670" data-end="1701">
<td data-start="1670" data-end="1684" data-col-size="sm">Çiftleşme Yaşamı</td>
<td data-start="1684" data-end="1701" data-col-size="sm">≥ 1000 döngü</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1703" data-end="1706" />
<h3 data-start="1708" data-end="1745">Mekanik ve inşaat detayları</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="1747" data-end="2066">
<thead data-start="1747" data-end="1774">
<tr data-start="1747" data-end="1774">
<th class="" data-start="1747" data-end="1757" data-col-size="sm">Özellik</th>
<th class="" data-start="1757" data-end="1774" data-col-size="sm">Şartname</th>
</tr>
</thead>
<tbody data-start="1785" data-end="2066">
<tr data-start="1785" data-end="1821">
<td data-start="1785" data-end="1804" data-col-size="sm">Konektör Formatı</td>
<td data-start="1804" data-end="1821" data-col-size="sm"><strong data-start="1806" data-end="1819">LC Dubleks</strong></td>
</tr>
<tr data-start="1822" data-end="1853">
<td data-start="1822" data-end="1839" data-col-size="sm">Kablo Çapı</td>
<td data-col-size="sm" data-start="1839" data-end="1853"><strong data-start="1841" data-end="1851">2.0 mm</strong></td>
</tr>
<tr data-start="1854" data-end="1892">
<td data-start="1854" data-end="1864" data-col-size="sm">Yüksük</td>
<td data-col-size="sm" data-start="1864" data-end="1892">1,25 mm zirkonya seramik</td>
</tr>
<tr data-start="1893" data-end="1938">
<td data-start="1893" data-end="1909" data-col-size="sm">Gövde Rengi</td>
<td data-start="1909" data-end="1938" data-col-size="sm"><strong data-start="1911" data-end="1923">Gül Kırmızısı</strong> (OM4/OM5 ID)</td>
</tr>
<tr data-start="1939" data-end="1963">
<td data-start="1939" data-end="1947" data-col-size="sm">Mandal</td>
<td data-col-size="sm" data-start="1947" data-end="1963">LC itme-çekme</td>
</tr>
<tr data-start="1964" data-end="1997">
<td data-start="1964" data-end="1971" data-col-size="sm">Çizme</td>
<td data-col-size="sm" data-start="1971" data-end="1997">Standart gerilim azaltma</td>
</tr>
<tr data-start="1998" data-end="2035">
<td data-start="1998" data-end="2015" data-col-size="sm">Çalışma Sıcaklığı</td>
<td data-start="2015" data-end="2035" data-col-size="sm">-40 °C ila +75 °C</td>
</tr>
<tr data-start="2036" data-end="2066">
<td data-start="2036" data-end="2055" data-col-size="sm">Çekme Dayanımı</td>
<td data-start="2055" data-end="2066" data-col-size="sm">≥ 100 N</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2068" data-end="2190">Bu <strong data-start="2072" data-end="2089">2.0 mm ceket</strong> dengeler <strong data-start="2099" data-end="2132">esneklik ve çekme kuvveti</strong>, için idealdir. <strong data-start="2144" data-end="2180">raftan rafa ve cihazdan panele</strong> Yama.</p>
<hr data-start="2192" data-end="2195" />
<h3 data-start="2197" data-end="2221">En iyi uyduğu yer</h3>
<ul data-start="2223" data-end="2414">
<li data-start="2223" data-end="2261">
<p data-start="2225" data-end="2261">Veri merkezi anahtarından anahtara bağlantılar</p>
</li>
<li data-start="2262" data-end="2306">
<p data-start="2264" data-end="2306">Sunucu ve depolama bağlantıları (SR optik)</p>
</li>
<li data-start="2307" data-end="2337">
<p data-start="2309" data-end="2337">MPO-LC kesme tertibatları</p>
</li>
<li data-start="2338" data-end="2372">
<p data-start="2340" data-end="2372">Kurumsal LAN ve SAN omurgaları</p>
</li>
<li data-start="2373" data-end="2414">
<p data-start="2375" data-end="2414">Çok modlu test ve izleme jumperları</p>
</li>
</ul>]]></content:encoded>
					
					<wfw:commentrss>https://www.fenxifiber.com/tr/product/lc-upc-2-0mm-duplex-multimode-gul-kirmizi/feed/</wfw:commentrss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>