FC/UPC-SC/UPC-OM3-DX Çok Modlu Fiber Optik Yama Kablosu

Bu FC/UPC–SC/UPC-OM3-DX bir duplex OM3 multimode patch cord engineered for environments that require mechanical stability on one end and high-density connectivity on the other. With a threaded FC connector paired to a push-pull SC interface, this cable is widely used in telecom rooms, optical test setups, and data center distribution frames.

İle inşa edilmiştir 50/125 μm laser-optimized OM3 fiber, it fully supports 10G, 40G, and 100G Ethernet over short-reach multimode optics.

Açıklama

Why FC to SC Makes Sense

FC connectors are favored in measurement equipment and carrier networks because their screw-on metal body prevents micro-movement that can cause optical instability.
SC connectors, by contrast, are standard in ODFs, patch panels, and switches for their snap-in reliability and easy handling.

This hybrid design lets you connect precision-grade FC devices directly to SC-based network infrastructure without adapters or signal degradation.


Optical & Mechanical Specifications

Özellik FC/UPC–SC/UPC-OM3-DX
Elyaf Tipi OM3 Çok Modlu 50/125 μm
Lif Sayısı Dubleks (DX)
Konektör A FC / UPC
Konektör B SC / UPC
Çalışma Dalga Boyu 850 nm / 1300 nm
Bant Genişliği @ 850 nm 2000 MHz-km
Ekleme Kaybı ≤ 0,30 dB
Geri Dönüş Kaybı ≥ 30 dB
10G Ethernet 300 m'ye kadar
40G / 100G 100 m'ye kadar
Jacket Options LSZH veya PVC
Uyumluluk IEC, TIA-568, RoHS, REACH

Where It’s Commonly Deployed

  • Telekom merkez ofisleri

  • OTDRs, power meters, and test benches

  • Data center cross-connects

  • Campus fiber backbones

  • Industrial and broadcast networks

OM3’s high bandwidth ensures clean signal transmission even when multiple patch points are involved.


Engineered for Optical Consistency

Each FC–SC OM3 jumper is assembled with ceramic ferrules and UPC-polished end faces, then 100% tested for insertion loss, reflectance, and geometry. This ensures low back reflection, high coupling efficiency, and long service life.

Bu LSZH ceket seçeneği meets modern fire-safety and low-smoke standards required in commercial buildings and data centers.


Profesyonel Soru-Cevap

Q1: Why use FC connectors in modern networks?
FC connectors offer exceptional stability and are still widely used in test equipment and carrier-grade systems.

Q2: Can OM3 support 100G Ethernet?
Evet. OM3 şunları destekler 100G up to 100 meters using 850 nm multimode transceivers.

Q3: Is this cable suitable for patch panels?
Kesinlikle. Bu SC end plugs directly into standard ODFs and network panels.

Q4: Does UPC polishing matter?
Yes. UPC polishing reduces reflection and maintains geri dönüş kaybı ≥ 30 dB, improving link reliability.