{"id":1158,"date":"2026-09-18T00:07:28","date_gmt":"2026-09-18T00:07:28","guid":{"rendered":"https:\/\/www.fenxifiber.com\/patch-cord-jacket-diameter-selection\/"},"modified":"2026-09-18T00:07:28","modified_gmt":"2026-09-18T00:07:28","slug":"baglanti-kablosu-kilif-capinin-secimi","status":"publish","type":"post","link":"https:\/\/www.fenxifiber.com\/tr\/patch-cord-jacket-diameter-selection\/","title":{"rendered":"Fiber Optik Ba\u011flant\u0131 Kablosu K\u0131l\u0131f Se\u00e7im K\u0131lavuzu | Fenxi"},"content":{"rendered":"<p>\u0130ki ba\u011flant\u0131 kablosu foto\u011frafta birbirinin ayn\u0131s\u0131 gibi g\u00f6r\u00fcnebilir, ancak sahada farkl\u0131 performans g\u00f6sterebilir. Kablo k\u0131l\u0131f\u0131n\u0131n bile\u015fimi, denet\u00e7inin kablo d\u00f6\u015femesini onaylay\u0131p onaylamayaca\u011f\u0131n\u0131 belirler; kablo \u00e7ap\u0131 ise kablonun raf kap\u0131s\u0131n\u0131n arkas\u0131ndaki k\u0131vr\u0131m\u0131 atlat\u0131p atlatamayaca\u011f\u0131n\u0131 belirler. Her ikisini de tek bir kalem olarak de\u011ferlendiren al\u0131c\u0131lar, teslimattan aylar sonra reddedilen bir teslimat veya aral\u0131kl\u0131 ba\u011flant\u0131 \u015feklinde bu uyumsuzlukla kar\u015f\u0131la\u015f\u0131rlar.<\/p>\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/02\/LC-UPC-2.0mm-Simplex-with-Short-Boot.jpg\" alt=\"2,0 mm k\u0131l\u0131fl\u0131 ve k\u0131sa LC u\u00e7lu fiber optik ba\u011flant\u0131 kablosu\" width=\"1200\" height=\"800\" \/><\/figure>\n<h2>K\u0131l\u0131f Malzemesi ve Kablo \u00c7ap\u0131, \u0130ki Ayr\u0131 Karard\u0131r<\/h2>\n<p>Bir k\u0131l\u0131f bile\u015fimi ile yang\u0131n s\u0131n\u0131fland\u0131rmas\u0131 farkl\u0131 kavramlar\u0131 ifade eder ve bu ikisini birbirine kar\u0131\u015ft\u0131rmak, \u00e7o\u011fu teklif talebinde (RFQ) yap\u0131lan hatan\u0131n temel nedenidir. PVC, LSZH, TPU veya PE gibi bile\u015fik, kablonun yang\u0131nda nas\u0131l davranaca\u011f\u0131n\u0131, ne kadar duman yayaca\u011f\u0131n\u0131 ve so\u011fukta ne kadar esnek kalaca\u011f\u0131n\u0131 belirler. OFNR, OFNP veya b\u00f6lgesel bir e\u015fde\u011feri gibi s\u0131n\u0131fland\u0131rma ise kablonun hangi kurulum alan\u0131na d\u00f6\u015fenebilece\u011fini belirtir. Bir kablo d\u00fc\u015f\u00fck dumanl\u0131 olabilir ancak y\u00fckseltici sertifikas\u0131na sahip olmayabilir; ayn\u0131 \u015fekilde, bitmi\u015f yap\u0131s\u0131 testi ge\u00e7mi\u015fse bir PVC kablo plenum sertifikas\u0131na sahip olabilir. LSZH'yi yang\u0131n s\u0131n\u0131f\u0131 ile e\u015fanlaml\u0131 olarak ele almak, denet\u00e7inin asl\u0131nda kontrol etti\u011fi k\u0131sm\u0131 g\u00f6zden ka\u00e7\u0131rmak anlam\u0131na gelir.<\/p>\n<p>\u00c7ap, farkl\u0131 bir eksende de\u011ferlendirilir. 3,0 mm\u2019lik bir dubleks kablo, kullan\u0131m a\u00e7\u0131s\u0131ndan rahatt\u0131r ve kablo d\u00fczenleyicide esneklik sa\u011flar; 2,0 mm\u2019lik bir kablo ise yakla\u015f\u0131k yar\u0131s\u0131 kadar bir kesit alan\u0131yla ayn\u0131 optik performans\u0131 sunar; bu durum, 48 adet dubleks ba\u011flant\u0131 noktas\u0131n\u0131n tek bir raf biriminden \u00e7\u0131kar\u0131lmas\u0131 gerekti\u011finde \u00f6nem kazan\u0131r. Teorik olarak bak\u0131ld\u0131\u011f\u0131nda, iki boyut aras\u0131nda bir \u00fcst\u00fcnl\u00fck s\u00f6z konusu de\u011fildir. Do\u011fru cevap, patch panosundaki yo\u011funlu\u011fa, g\u00fczerg\u00e2h\u0131n gerektirdi\u011fi b\u00fck\u00fclme yar\u0131\u00e7aplar\u0131na ve kablonun ne s\u0131kl\u0131kla yeniden ba\u011flanaca\u011f\u0131na ba\u011fl\u0131d\u0131r.<\/p>\n<h2>Yang\u0131n Dayan\u0131kl\u0131l\u0131k Standartlar\u0131: PVC, LSZH, OFNR ve OFNP\u2019nin Uygulanabilece\u011fi Alanlar<\/h2>\n<p>Tablo, al\u0131c\u0131lar\u0131n en s\u0131k kar\u015f\u0131la\u015ft\u0131\u011f\u0131 d\u00f6rt i\u015faretlemeyi, bunlar\u0131n temelini olu\u015fturan test verileriyle e\u015fle\u015ftirir. Tek bir kablo, ayn\u0131 anda iki i\u015fareti de ta\u015f\u0131yabilir; \u00f6rne\u011fin, bir LSZH bile\u015fi\u011fi ayn\u0131 zamanda bir y\u00fckseltici listelemesine de sahip olabilir.<\/p>\n<table>\n<thead>\n<tr>\n<th>Ceket mi, yoksa i\u015faret mi?<\/th>\n<th>Neyi anlat\u0131yor?<\/th>\n<th>Test esaslar\u0131<\/th>\n<th>Neler kontrol edilmelidir?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>PVC<\/td>\n<td>Polimer bile\u015fi\u011fi: maliyet, esneklik, a\u015f\u0131nma<\/td>\n<td>Yang\u0131n s\u0131n\u0131f\u0131, malzeme ad\u0131ndan de\u011fil, s\u0131n\u0131fland\u0131rma listesinden belirlenir<\/td>\n<td>Bask\u0131l\u0131 kapak a\u00e7\u0131klamas\u0131 ve test raporu<\/td>\n<\/tr>\n<tr>\n<td>LSZH<\/td>\n<td>D\u00fc\u015f\u00fck dumanl\u0131, halojen i\u00e7ermeyen bile\u015fik<\/td>\n<td>IEC 60332-1-2, IEC 60754-1 \/ -2, IEC 61034-2<\/td>\n<td>\u00d6l\u00e7\u00fclen duman ve asit gaz\u0131 de\u011ferleri<\/td>\n<\/tr>\n<tr>\n<td>OFNR<\/td>\n<td>Y\u00fckseltici listesi, iletken olmayan optik kablo<\/td>\n<td>UL 1666<\/td>\n<td>Liste numaras\u0131 ve alan s\u0131n\u0131fland\u0131rmas\u0131<\/td>\n<\/tr>\n<tr>\n<td>OFNP<\/td>\n<td>Plenum s\u0131n\u0131f\u0131, en y\u00fcksek yang\u0131n s\u0131n\u0131f\u0131<\/td>\n<td>UL 910 \/ NFPA 262<\/td>\n<td>Herhangi bir ikame i\u00e7in yaz\u0131l\u0131 onay<\/td>\n<\/tr>\n<tr>\n<td>Z\u0131rhl\u0131 \/ PE<\/td>\n<td>Yaln\u0131zca mekanik ve \u00e7evresel koruma<\/td>\n<td>IEC 60794 serisi ezilme ve \u00e7ekme testleri<\/td>\n<td>Herhangi bir yang\u0131n kayd\u0131 olmad\u0131\u011f\u0131 varsay\u0131l\u0131r<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/02\/LC-UPC-3.0mm-Duplex-Singlemode.jpg\" alt=\"D\u00fc\u015f\u00fck dumanl\u0131, halojensiz k\u0131l\u0131fl\u0131 LC \u00e7ift y\u00f6nl\u00fc tek modlu ba\u011flant\u0131 kablosu\" width=\"1200\" height=\"800\" \/><\/figure>\n<p>As\u0131l \u00f6nemli olan, hangi bile\u015fi\u011fin en iyi oldu\u011fu de\u011fil, o alan i\u00e7in hangi sertifikasyonun gerekli oldu\u011fudur. Kuzey Amerika\u2019da hava i\u015fleme kural\u0131 NEC Madde 770\u2019ten kaynaklanmaktad\u0131r ve bu kural\u0131n temelini olu\u015fturan iki test \u015funlard\u0131r: <a href=\"https:\/\/www.ul.com\/\" target=\"_blank\" rel=\"noopener\">UL 910 (NFPA 262)<\/a> plenum i\u00e7in ve y\u00fckseltici i\u00e7in UL 1666; kablo standard\u0131n\u0131n kendisi ise \u015fu kurum taraf\u0131ndan yay\u0131nlanm\u0131\u015ft\u0131r: <a href=\"https:\/\/www.nfpa.org\/\" target=\"_blank\" rel=\"noopener\">NFPA<\/a>. Hava geri d\u00f6n\u00fc\u015f\u00fc sa\u011flayan tavan\u0131n \u00fczerine yerle\u015ftirilmi\u015f, plenum i\u00e7ermeyen bir kablo, y\u00f6netmelik ihlali te\u015fkil eder; bu durum genellikle denetim s\u0131ras\u0131nda tespit edilir ve de\u011fi\u015ftirilmesi i\u00e7in kablonun tamam\u0131n\u0131n yeniden d\u00f6\u015fenmesi gerekir.<\/p>\n<p>Avrupa, Orta Do\u011fu ve Asya\u2019n\u0131n b\u00fcy\u00fck bir k\u0131sm\u0131nda, bu karar bir UL dosya numaras\u0131 yerine IEC test sonu\u00e7lar\u0131na g\u00f6re al\u0131nmaktad\u0131r. D\u00fc\u015f\u00fck dumanl\u0131, halojensiz kablo, duman yo\u011funlu\u011fu ve asitli gazlar nedeniyle tercih edilmektedir: IEC 61034-2 standard\u0131 duman\u0131 s\u0131n\u0131rlarken, IEC 60754-2 standard\u0131 ise ayn\u0131 odadaki ekipmana zarar verebilecek gazlar\u0131n asitli\u011fini s\u0131n\u0131rlamaktad\u0131r. <a href=\"https:\/\/webstore.iec.ch\/\" target=\"_blank\" rel=\"noopener\">IEC \u00e7evrimi\u00e7i ma\u011fazas\u0131<\/a> Test y\u00f6ntemleri burada s\u0131ralanm\u0131\u015ft\u0131r; dosyan\u0131za eklemeniz gerekenler \u00f6l\u00e7\u00fclen de\u011ferlerdir. \u0130ki kablonun her ikisi de LSZH olarak etiketlenmi\u015f olabilir; ancak bunlardan birinde y\u00fczde 60 \u0131\u015f\u0131k ge\u00e7irgenli\u011fi g\u00f6steren bir rapor bulunurken, di\u011ferinde hi\u00e7bir belge bulunmayabilir.<\/p>\n<p>K\u0131l\u0131f malzemesi de \u00e7al\u0131\u015fma aral\u0131\u011f\u0131n\u0131 belirler: Standart malzemeler kullan\u0131m s\u0131ras\u0131nda yakla\u015f\u0131k eksi 20 ila art\u0131 70 santigrat derece aral\u0131\u011f\u0131nda \u00e7al\u0131\u015f\u0131r; d\u00fc\u015f\u00fck s\u0131cakl\u0131k veya z\u0131rhl\u0131 versiyonlar ise eksi 40 dereceye kadar iner; bu durum, \u0131s\u0131tmas\u0131z bar\u0131naklar ve Kuzey Avrupa\u2019daki kabinler i\u00e7in \u00f6nemlidir.<\/p>\n<h2>2,0 mm, 3,0 mm ve 0,9 mm: Yo\u011fun Raflar \u0130\u00e7in \u00c7ap Se\u00e7enekleri<\/h2>\n<table>\n<thead>\n<tr>\n<th>Kablo veya tampon boyutu<\/th>\n<th>Ait oldu\u011fu yer<\/th>\n<th>Kullan\u0131m s\u0131ras\u0131nda minimum b\u00fck\u00fclme yar\u0131\u00e7ap\u0131<\/th>\n<th>Kurulum notu<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0,9 mm tamponlu<\/td>\n<td>Tepelikler, tepsilere ve ODF panellerine eklenmi\u015ftir<\/td>\n<td>10 mm<\/td>\n<td>Asla elle yiv a\u00e7\u0131lmamal\u0131d\u0131r; bir tepsi i\u00e7inde saklay\u0131n\u0131z<\/td>\n<\/tr>\n<tr>\n<td>1,6 \u2013 1,8 mm<\/td>\n<td>Kaset tabanl\u0131 y\u00fcksek yo\u011funluklu ba\u011flant\u0131<\/td>\n<td>16 \u2013 18 mm<\/td>\n<td>\u00d6ncelikle \u00f6ny\u00fckleme uyumlulu\u011funu do\u011frulay\u0131n<\/td>\n<\/tr>\n<tr>\n<td>2.0 mm<\/td>\n<td>Yo\u011fun raflar, LC uniboot, s\u0131k\u0131 y\u00f6neticiler<\/td>\n<td>20 mm<\/td>\n<td>Yo\u011funluk ve kullan\u0131m kolayl\u0131\u011f\u0131 aras\u0131nda en iyi denge<\/td>\n<\/tr>\n<tr>\n<td>2,4 mm<\/td>\n<td>Kar\u0131\u015f\u0131k paneller ve eski SC dubleks<\/td>\n<td>24 mm<\/td>\n<td>Panel ba\u011flant\u0131 noktas\u0131 aral\u0131\u011f\u0131n\u0131 kontrol edin<\/td>\n<\/tr>\n<tr>\n<td>3.0 mm<\/td>\n<td>Standart telekom ve FTTH kablo ba\u011flant\u0131lar\u0131<\/td>\n<td>30 mm<\/td>\n<td>En toleransl\u0131, en d\u00fc\u015f\u00fck yo\u011funluklu<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/02\/LC-UPC-0.9mm-Simplex-Singlemode.jpg\" alt=\"Ek tepsisi sonland\u0131rmas\u0131 i\u00e7in 0,9 mm tamponlu simpleks fiber pigtail\" width=\"1200\" height=\"800\" \/><\/figure>\n<p>Tablodaki yar\u0131\u00e7ap, d\u0131\u015f \u00e7ap\u0131n on kat\u0131 olan kullan\u0131m s\u0131n\u0131r\u0131n\u0131 g\u00f6sterir. Kablo \u00e7ekilirken veya d\u00f6\u015fenirken bu de\u011fer yirmi kat\u0131na \u00e7\u0131kar: 3,0 mm\u2019lik bir kablo i\u00e7in 60 mm, 2,0 mm\u2019lik bir kablo i\u00e7in 40 mm. \u00c7al\u0131\u015f\u0131r durumdaki bir rafta bu, genellikle sat\u0131n alma karar\u0131n\u0131 belirleyen k\u0131s\u0131tlay\u0131c\u0131 fakt\u00f6rd\u00fcr; \u00e7\u00fcnk\u00fc 3,0 mm'lik bir kablo hava ak\u0131\u015f\u0131na do\u011fru e\u011filebilirken, 2,0 mm'lik bir kablo uzak ba\u011flant\u0131 noktas\u0131na sorunsuz bir \u015fekilde ula\u015fabilir.<\/p>\n<p>B\u00fck\u00fclmeye dayan\u0131kl\u0131 fiber, optik \u00f6zellikleri de\u011fi\u015ftirir; k\u0131l\u0131f\u0131 de\u011fil. ITU-T G.657 A1 ve A2 fiberleri, tavsiye belgesinde tan\u0131mlanan 15 mm ve 7,5 mm b\u00fck\u00fclme yar\u0131\u00e7aplar\u0131n\u0131n alt\u0131nda zay\u0131flama de\u011ferlerini korur; ancak etraf\u0131ndaki kablo, mekanik bir minimum seviyeyi sa\u011flar. Bir G.657.A2 kablosu, kablo tepsisinin arkas\u0131nda 15 mm\u2019lik bir b\u00fck\u00fclmeye izin vermez; bu kablo, gerilimin en y\u00fcksek oldu\u011fu konekt\u00f6r\u00fcn son 30 mm\u2019sinde bir marj sa\u011flar. Fiber s\u0131n\u0131f\u0131 ve k\u0131l\u0131f boyutu, sat\u0131n alma sipari\u015finde ayr\u0131 sat\u0131rlar olarak yer al\u0131r ve s\u0131n\u0131f mant\u0131\u011f\u0131, k\u0131lavuzumuzda ele al\u0131nmaktad\u0131r. <a href=\"https:\/\/www.fenxifiber.com\/tr\/os2-om4-baglanti-kablosu-secimi\/\">OS2 ve OM4 ba\u011flant\u0131 kablosu se\u00e7imi<\/a>.<\/p>\n<p>Yo\u011funluk aritmetiktir. 24 adet \u00e7ift y\u00f6nl\u00fc LC ba\u011flant\u0131 noktas\u0131na sahip on iki panel, bir raf y\u00fcz\u00fcne 288 konekt\u00f6r yerle\u015ftirir. 3,0 mm'lik bir \u00e7ift y\u00f6nl\u00fc kablo, 3,0 x 6,0 mm'lik bir kesit kaplar; 2,0 mm'lik bir \u00e7ift y\u00f6nl\u00fc kablo ise 2,0 x 4,0 mm'lik bir kesit kaplar. On iki panel boyunca bu bo\u015fluk, kablo d\u00fczenleyicinin hala kapan\u0131p kapanmayaca\u011f\u0131n\u0131 belirler. Her iki boyut da, ferrule, cilalama ve hizalama man\u015fonu taraf\u0131ndan belirlenen yerle\u015ftirme kayb\u0131n\u0131 veya geri d\u00f6n\u00fc\u015f kayb\u0131n\u0131 de\u011fi\u015ftirmez.<\/p>\n<h2>Ba\u011flant\u0131 Noktas\u0131nda B\u00fck\u00fclme Yar\u0131\u00e7ap\u0131, \u00c7ekme Y\u00fck\u00fc ve Gerilim Giderme<\/h2>\n<p>Dar virajlar, mekanik b\u00fct\u00e7enin yaln\u0131zca bir par\u00e7as\u0131n\u0131 olu\u015fturur ve teslimat s\u0131ras\u0131nda en s\u0131k test edilen k\u0131s\u0131md\u0131r. Konekt\u00f6rdeki gerilme ve yan y\u00fck, sahada daha fazla ar\u0131zaya neden olur; ancak bunlar\u0131n hi\u00e7biri kabul g\u00fcn\u00fcnde yap\u0131lan kay\u0131p testinde ortaya \u00e7\u0131kmaz.<\/p>\n<ul>\n<li>B\u00fck\u00fclme yar\u0131\u00e7ap\u0131: \u00c7al\u0131\u015fma s\u0131ras\u0131nda d\u0131\u015f \u00e7ap\u0131n on kat\u0131, \u00e7ekme s\u0131ras\u0131nda yirmi kat\u0131.<\/li>\n<li>\u00c7ekme y\u00fck\u00fc: aramid ipli\u011fi taraf\u0131ndan ta\u015f\u0131n\u0131r, lif taraf\u0131ndan de\u011fil. Kesin yap\u0131ya ili\u015fkin k\u0131sa vadeli ve uzun vadeli de\u011ferleri isteyin.<\/li>\n<li>Yan y\u00fck ve gerilim azaltma: s\u0131k\u0131\u015ft\u0131r\u0131lm\u0131\u015f ba\u011flar kullan\u0131lmamal\u0131, sadece c\u0131rt-c\u0131rt kullan\u0131lmal\u0131; k\u0131l\u0131f tam olarak oturmal\u0131d\u0131r, aksi takdirde y\u00fck ferrule\u2019a biner.<\/li>\n<li>\u00c7iftleme d\u00f6ng\u00fcleri: GR-326-CORE, 0,5 dB ekleme kayb\u0131 veya daha iyi bir de\u011ferle 500 d\u00f6ng\u00fcy\u00fc kapsar; geri d\u00f6n\u00fc\u015f kayb\u0131 ise UPC i\u00e7in 50 dB, APC i\u00e7in 60 dB\u2019dir.<\/li>\n<li>Kategori: IEC 61753-1 standard\u0131, kontroll\u00fc, kontrols\u00fcz ve d\u0131\u015f mekan kategorilerini tan\u0131mlamaktad\u0131r. Kategoriyi katalog sayfas\u0131na de\u011fil, kabine g\u00f6re se\u00e7iniz.<\/li>\n<\/ul>\n<p>Bir konekt\u00f6r yandan tak\u0131ld\u0131\u011f\u0131nda veya bir k\u0131vr\u0131m k\u0131l\u0131f\u0131n \u00e7ok yak\u0131n\u0131na geldi\u011finde, geri d\u00f6n\u00fc\u015f kayb\u0131 ilk olarak ortaya \u00e7\u0131kar. Yay\u0131nlanan kay\u0131p s\u0131n\u0131rlar\u0131: <a href=\"https:\/\/www.flukenetworks.com\/knowledge-base\/fiber-optic-loss-budget\" target=\"_blank\" rel=\"noopener\">Fluke Networks<\/a> kabul maddesine yaz\u0131labilecek ger\u00e7ek\u00e7i bir rakamd\u0131r.<\/p>\n<h2>A\u00e7\u0131k Hava, Z\u0131rhl\u0131 ve End\u00fcstriyel Ceket Se\u00e7enekleri<\/h2>\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.fenxifiber.com\/wp-content\/uploads\/2026\/09\/outdoor-armored-fiber-cable-cross-section.jpg\" alt=\"PE k\u0131l\u0131fl\u0131 ve takviye elemanl\u0131 z\u0131rhl\u0131 d\u0131\u015f mekan fiber kablonun kesiti\" width=\"1200\" height=\"800\" \/><\/figure>\n<p>\u0130\u00e7 mekan ve d\u0131\u015f mekan kablolar\u0131 farkl\u0131 \u00fcr\u00fcnlerdir ve hi\u00e7bir yang\u0131n sertifikas\u0131 bu s\u0131n\u0131r\u0131 her iki y\u00f6nde de a\u015fmaz. Bir d\u0131\u015f mekan kablosu, UV \u0131\u015f\u0131nlar\u0131na ve neme kar\u015f\u0131 diren\u00e7 sa\u011flamak i\u00e7in siyah polietilen bir d\u0131\u015f k\u0131l\u0131fa ve ayr\u0131ca IEC 60794 serisinin ezilme, darbe ve gerilme gereksinimlerini kar\u015f\u0131layan bir yap\u0131ya sahip olmal\u0131d\u0131r. Bir kanaldan ge\u00e7en bir i\u00e7 mekan LSZH kablosu, ilk kay\u0131p testini ge\u00e7ebilir ancak bir sezon i\u00e7inde ar\u0131zalanabilir.<\/p>\n<p>G\u00fczerg\u00e2h\u0131n a\u00e7\u0131kta kald\u0131\u011f\u0131 yerlere z\u0131rh eklenir: do\u011frudan topra\u011fa g\u00f6mme uygulamalar\u0131 ve end\u00fcstriyel kabinler i\u00e7in oluklu \u00e7elik \u015ferit; kemirgenlerin girmesine a\u00e7\u0131k kanallar i\u00e7in ise birbirine kenetlenen z\u0131rh. Konekt\u00f6r\u00fcn a\u00e7\u0131k havada bulundu\u011fu yerlerde, ODVA veya FullAXS gibi sertle\u015ftirilmi\u015f IP67 aray\u00fcz\u00fc, dubleks ba\u011flant\u0131 noktas\u0131n\u0131n yerini tamamen al\u0131r ve kablo, fabrikada sonland\u0131r\u0131lm\u0131\u015f sabit uzunlukta bir montaj haline gelir.<\/p>\n<h2>Cekete Uygun Ba\u011flant\u0131 Par\u00e7as\u0131, Man\u015fet ve Cilalama<\/h2>\n<p>Ba\u011flant\u0131 noktas\u0131, daha \u00f6nce se\u00e7ilen \u00e7apla uyumlu olmal\u0131d\u0131r. 2,0 mm\u2019lik bir kablo, do\u011fal olarak <a href=\"https:\/\/www.fenxifiber.com\/tr\/product-category\/lc-konnektor\/\">LC tek par\u00e7a ve k\u0131sa \u00f6ny\u00fckleme tertibatlar\u0131<\/a>, burada yuvarlak bir k\u0131l\u0131f her iki fiberi de ta\u015f\u0131r ve tek bir it-\u00e7ek mandal\u0131 bu ikiliyi serbest b\u0131rak\u0131r. 3,0 mm\u2019lik dubleks kablo, standart SC ve LC u\u00e7lar ile karma panellere uygundur. U\u00e7 uzunlu\u011fu panel derinli\u011fiyle ayn\u0131 olmal\u0131d\u0131r; zira s\u0131\u011f bir kasetin i\u00e7indeki uzun bir u\u00e7, kapa\u011f\u0131n kapanmas\u0131n\u0131 engeller.<\/p>\n<p>Ba\u011flant\u0131 boyunca cilalama tutarl\u0131 olmal\u0131d\u0131r. LC\/UPC ve SC\/UPC, mavi g\u00f6vdelerle birle\u015ftirilir ve geri d\u00f6n\u00fc\u015f kayb\u0131n\u0131 50 dB veya daha iyi bir seviyede tutar; LC\/APC ve SC\/APC ise ye\u015fil g\u00f6vdeler kullan\u0131r ve 60 dB veya daha iyi bir de\u011fere ula\u015f\u0131r; bu nedenle FTTH ayr\u0131mlar\u0131nda yayg\u0131n olarak kullan\u0131l\u0131rlar. Bir APC ferrule asla bir UPC ferrule ile birle\u015ftirilmemelidir; \u00e7\u00fcnk\u00fc a\u00e7\u0131l\u0131 u\u00e7 y\u00fczeyi sadece kenardan temas eder, hava bo\u015flu\u011fu geri d\u00f6n\u00fc\u015f kayb\u0131n\u0131 bozar ve bu hasar foto\u011frafta g\u00f6r\u00fcnmez.<\/p>\n<ul>\n<li>K\u0131l\u0131f rengi, fiber s\u0131n\u0131f\u0131na g\u00f6re belirlenir: OS2 tek modlu fiber i\u00e7in sar\u0131, OM3 ve OM4 i\u00e7in su ye\u015fili, OM5 i\u00e7in limon ye\u015fili; bu, \u015fu \u015fekilde belirlenmi\u015ftir: <a href=\"https:\/\/www.tiaonline.org\/\" target=\"_blank\" rel=\"noopener\">TIA-568<\/a>.<\/li>\n<li>Sipari\u015f formunda uzunluk tolerans\u0131n\u0131 belirtin; \u00e7\u00fcnk\u00fc yar\u0131m metre fazladan gev\u015feklik, kar\u015f\u0131 limana ula\u015famayan bir halattan daha kabul edilebilir bir durumdur.<\/li>\n<\/ul>\n<p>Tek modlu ve \u00e7ok modlu kablolar ayn\u0131 k\u0131l\u0131f se\u00e7enekleriyle stokta bulundurulmaktad\u0131r, bu nedenle <a href=\"https:\/\/www.fenxifiber.com\/tr\/product-category\/tek-modlu-fiber-optik-baglanti-kablosu\/\">tek modlu ba\u011flant\u0131 kablosu serisi<\/a> ve <a href=\"https:\/\/www.fenxifiber.com\/tr\/product-category\/cok-modlu-fiber-optik-baglanti-kablosu\/\">\u00e7ok modlu ba\u011flant\u0131 kablosu serisi<\/a> tek bir teknik \u00f6zellik belgesine g\u00f6re sipari\u015f edilebilir. B\u00fct\u00fcn\u00fcn\u00fc koruyarak <a href=\"https:\/\/www.fenxifiber.com\/tr\/product-category\/fiber-optik-baglanti-kablosu\/\">ba\u011flant\u0131 kablosu katalo\u011fu<\/a> Tek bir ceket ve \u00e7ap standard\u0131, kablolar\u0131n yar\u0131s\u0131n\u0131n denetimden ge\u00e7ip di\u011fer yar\u0131s\u0131n\u0131n ge\u00e7emedi\u011fi kar\u0131\u015f\u0131k bir teslimat\u0131 \u00f6nler.<\/p>\n<h2>Standartlar Sayfas\u0131: Teklif Talebine (RFQ) Neler Eklenmelidir?<\/h2>\n<table>\n<thead>\n<tr>\n<th>Standart m\u0131, yoksa test mi?<\/th>\n<th>Kapsam<\/th>\n<th>Tedarik\u00e7iden ne talep edilmeli<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>IEC 60332-1-2<\/td>\n<td>Tek bir yal\u0131t\u0131ml\u0131 iletken \u00fczerinde dikey alev yay\u0131l\u0131m\u0131<\/td>\n<td>Kablonun tam yap\u0131s\u0131n\u0131 belirten rapor<\/td>\n<\/tr>\n<tr>\n<td>IEC 60754-1 \/ -2<\/td>\n<td>Yanma gazlar\u0131ndaki halojenli asit gaz\u0131 i\u00e7eri\u011fi ve asitlik derecesi<\/td>\n<td>\u00d6l\u00e7\u00fclen pH ve iletkenlik de\u011ferlerini i\u00e7eren bile\u015fik beyan\u0131<\/td>\n<\/tr>\n<tr>\n<td>IEC 61034-2<\/td>\n<td>Tan\u0131mlanm\u0131\u015f yanma ko\u015fullar\u0131 alt\u0131nda duman yo\u011funlu\u011fu<\/td>\n<td>Bir iddia yerine \u0131\u015f\u0131k ge\u00e7irgenlik de\u011feri<\/td>\n<\/tr>\n<tr>\n<td>UL 1666 ve UL 910<\/td>\n<td>Kuzey Amerika i\u00e7in y\u00fckseltici ve da\u011f\u0131t\u0131m odas\u0131 performans\u0131<\/td>\n<td>Liste numaras\u0131 ve kapak \u00fczerindeki a\u00e7\u0131klama<\/td>\n<\/tr>\n<tr>\n<td>TIA-568.3-D<\/td>\n<td>Yap\u0131sal kablolamada kablo ve konekt\u00f6r performans\u0131<\/td>\n<td>Fiber s\u0131n\u0131f\u0131na g\u00f6re zay\u0131flama ve bant geni\u015fli\u011fi verileri<\/td>\n<\/tr>\n<tr>\n<td>IEC 61753-1 ve GR-326<\/td>\n<td>Konekt\u00f6r performans kategorileri ve g\u00fcvenilirli\u011fi<\/td>\n<td>Kategoriye ve test edilen \u00e7iftle\u015fme d\u00f6ng\u00fclerine g\u00f6re kay\u0131p s\u0131n\u0131rlar\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Teklif talebinde (RFQ), k\u0131l\u0131f bile\u015fimi, yanma s\u0131n\u0131f\u0131, kablo \u00e7ap\u0131 ve test raporu referans\u0131n\u0131 d\u00f6rt ayr\u0131 sat\u0131r halinde belirtin. Bu d\u00f6rt maddeye de belgelerle yan\u0131t veren bir tedarik\u00e7i, denetimden ge\u00e7ecektir; bro\u015f\u00fcrle yan\u0131t veren bir tedarik\u00e7i ise ilk ba\u011flant\u0131 testine kadar \u00fcstlenece\u011finiz bir risktir.<\/p>","protected":false},"excerpt":{"rendered":"<p>PVC, LSZH, OFNR ve OFNP patch kablo k\u0131l\u0131flar\u0131n\u0131 ve 2,0 mm ile 3,0 mm kablo \u00e7aplar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n. Sipari\u015f vermeden \u00f6nce yang\u0131n dayan\u0131kl\u0131l\u0131k s\u0131n\u0131f\u0131n\u0131, b\u00fck\u00fclme yar\u0131\u00e7ap\u0131n\u0131 ve ilgili standartlar\u0131 kontrol edin. Fiyat teklifi al\u0131n.<\/p>","protected":false},"author":1,"featured_media":879,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1158","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/posts\/1158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/comments?post=1158"}],"version-history":[{"count":0,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/posts\/1158\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/media\/879"}],"wp:attachment":[{"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/media?parent=1158"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/categories?post=1158"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fenxifiber.com\/tr\/wp-json\/wp\/v2\/tags?post=1158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}